Thermo-hydraulic analysis and numerical simulation of a parabolic trough solar collector for direct steam generation

被引:48
作者
Hachicha, Ahmed Amine [1 ]
Rodriguez, Ivette [2 ]
Ghenai, Chaouki [1 ]
机构
[1] Univ Sharjah, Sustainable & Renewable Energy Engn Dept, POB 27272, Sharjah, U Arab Emirates
[2] Univ Politecn Cataluna, Heat Engines Dept, BarcelonaTech, Barcelona, Spain
关键词
Direct Steam Generation; Parabolic trough; Tow phase flow model; Thermal gradient; Efficiency; HEAT-TRANSFER ANALYSIS; HORIZONTAL TUBES; PART I; FLOW; RECEIVER; MODEL; 2-PHASE;
D O I
10.1016/j.apenergy.2018.01.054
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Direct Steam Generation (DSG) is one of the most promising alternatives for parabolic trough solar plants to replace the synthetic oil and reduce the electricity cost. The focus of this work is to develop a comprehensive optical and thermo-hydraulic model for the performance prediction of DSG process under real operating conditions. Pressure drop and heat transfer characteristics are determined considering the effect of the non-uniform heat flux distribution due to the concentration of the sunlight. A numerical-geometrical method based on ray trace and finite volume method techniques is used to determine the solar flux distribution around the absorber tube with high accuracy. A heat transfer model based on energy balance is applied to predict the thermal performances of the different flow regimes in the DSG loop. The thermo-hydraulic behavior of the different DSG sections i.e. preheating, evaporation and superheating is investigated under different operating conditions. The validity of the model has been tested by being compared with experimental data from DISS test facility and other available models in the literature. The study also presents a comparative study of the effect of different parameters on the thermal gradient around the absorber tube. The analysis shows that the highest thermal gradient is occurring in the superheating section with a high risk of thermal bending and a potential damage risk. The model is also capable to evaluate the efficiency of a DSG loop for different conditions and help to take the appropriate control strategies to avoid flow instabilities in the DSG rows.
引用
收藏
页码:152 / 165
页数:14
相关论文
共 51 条
[1]   DSG under two-phase and stratified flow in a steel receiver of a parabolic trough collector [J].
Almanza, R ;
Jiménez, G ;
Lentz, A ;
Valdés, A ;
Soria, A .
JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2002, 124 (02) :140-144
[2]  
[Anonymous], P 9 INT HEAT TRANSF
[3]  
[Anonymous], 2003, HEAT TRANSFER ANAL M
[4]  
[Anonymous], 2013, ZUSTANDSGROSSEN WASS
[5]  
[Anonymous], 1944, T AM SOC MECH ENG AM
[6]   Analysis of the experimental behaviour of a 100 kWth latent heat storage system for direct steam generation in solar thermal power plants [J].
Bayon, Rocio ;
Rojas, Esther ;
Valenzuela, Loreto ;
Zarza, Eduardo ;
Leon, Javier .
APPLIED THERMAL ENGINEERING, 2010, 30 (17-18) :2643-2651
[7]   A quasi-dynamic simulation model for direct steam generation in parabolic troughs using TRNSYS [J].
Biencinto, Mario ;
Gonzalez, Lourdes ;
Valenzuela, Loreto .
APPLIED ENERGY, 2016, 161 :133-142
[8]   Chattering in dynamic mathematical two-phase flow models [J].
Bonilla, J. ;
Yebra, L. J. ;
Dormido, S. .
APPLIED MATHEMATICAL MODELLING, 2012, 36 (05) :2067-2081
[9]   Comparative and sensitive analysis for parabolic trough solar collectors with a detailed Monte Carlo ray-tracing optical model [J].
Cheng, Z. D. ;
He, Y. L. ;
Cui, F. Q. ;
Du, B. C. ;
Zheng, Z. J. ;
Xu, Y. .
APPLIED ENERGY, 2014, 115 :559-572
[10]   Approaches to modelling a solar field for direct generation of industrial steam [J].
Cundapi, Roger ;
Moya, Sara L. ;
Valenzuela, Loreto .
RENEWABLE ENERGY, 2017, 103 :666-681