Dynamic response of a shear stress transducer in the sliding plate rheometer

被引:7
|
作者
Kolitawong, C
Giacomin, AJ
机构
[1] Univ Wisconsin, Dept Mech Engn, Madison, WI 53706 USA
[2] Univ Wisconsin, Rheol Res Ctr, Madison, WI 53706 USA
[3] Natl Univ Singapore, Dept Chem & Environm Engn, Singapore 119260, Singapore
关键词
sliding plate rheometer; transducer damping; shear stress transducer; bipolar cylindrical coordinates; dynamic transducer calibration;
D O I
10.1016/S0377-0257(01)00139-2
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
The damping caused by polymer melt, which commonly gets into the housing of a shear stress transducer, is determined analytically. The analysis employs bipolar coordinates and is applied to Newtonian and then linear viscoelastic fluids, Results are compared with available dynamic calibration measurements, and also with previously used semi-empirical models for the transducer damping. Dimensionless graphs are then provided for estimating transducer attenuation and phase error in oscillatory shear measurements. Examples are given showing how to use the results for rheometer design and to assess measurement accuracy. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:71 / 96
页数:26
相关论文
共 50 条
  • [1] Frequency response of a shear stress transducer installed in a sliding plate rheometer
    Dealy, JM
    Jeyaseelan, RS
    JOURNAL OF RHEOLOGY, 1998, 42 (04) : 833 - 841
  • [2] A PARALLEL PLATE MELT RHEOMETER INCORPORATING A SHEAR-STRESS TRANSDUCER
    DEALY, JM
    SOONG, SS
    JOURNAL OF RHEOLOGY, 1984, 28 (04) : 355 - 365
  • [3] A sliding plate microgap rheometer for the simultaneous measurement of shear stress and first normal stress difference
    Baik, Seung Jae
    Moldenaers, Paula
    Clasen, Christian
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (03):
  • [4] Use of a sliding plate rheometer to measure the first normal stress difference at high shear rates
    Junke Xu
    Stéphane Costeux
    John M. Dealy
    Mark N. De Decker
    Rheologica Acta, 2007, 46 : 815 - 824
  • [5] Use of a sliding plate rheometer to measure the first normal stress difference at high shear rates
    Xu, Junke
    Costeux, Stephane
    Dealy, John M.
    De Decker, Mark N.
    RHEOLOGICA ACTA, 2007, 46 (06) : 815 - 824
  • [6] Dynamic Shear-Lag Model for Stress Transfer in Transducer Bonded to Plate
    Kapuria, Santosh
    Sharma, Bhabagrahi Natha
    Arockiarajan, A.
    AIAA JOURNAL, 2019, 57 (05) : 2123 - 2133
  • [7] Determining the true slip of a yield stress material with a sliding plate rheometer
    Christian Clasen
    Rheologica Acta, 2012, 51 : 883 - 890
  • [8] Determining the true slip of a yield stress material with a sliding plate rheometer
    Clasen, Christian
    RHEOLOGICA ACTA, 2012, 51 (10) : 883 - 890
  • [9] A NOVEL SLIDING PLATE RHEOMETER FOR MOLTEN PLASTICS
    GIACOMIN, AJ
    SAMURKAS, T
    DEALY, JM
    POLYMER ENGINEERING AND SCIENCE, 1989, 29 (08): : 499 - 504
  • [10] Transient shear flow behavior of concentrated long glass fiber suspensions in a sliding plate rheometer
    Ortman, Kevin C.
    Agarwal, Neeraj
    Eberle, Aaron P. R.
    Baird, Donald G.
    Wapperom, Peter
    Giacomin, A. Jeffrey
    JOURNAL OF NON-NEWTONIAN FLUID MECHANICS, 2011, 166 (16) : 884 - 895