The CMS Calorimeter Trigger for LHC Run II

被引:0
作者
Bundock, Aaron [1 ]
机构
[1] Imperial Coll Sci Tech Med GB, London, England
来源
17TH INTERNATIONAL CONFERENCE ON CALORIMETRY IN PARTICLE PHYSICS (CALOR2016) | 2017年 / 928卷
关键词
D O I
10.1088/1742-6596/928/1/012004
中图分类号
O59 [应用物理学];
学科分类号
摘要
The Compact Muon Solenoid (CMS) experiment has implemented a sophisticated two-level online selection system that achieves a rejection factor of nearly 10(5). During Run II, the LHC has increased its centre-of-mass energy up to 13 TeV and will progressively reach an instantaneous luminosity of 2x10(34) cm(-2) s(-1). In order to guarantee a successful and ambitious physics programme under this intense environment, the CMS Trigger and Data acquisition (DAQ) system has been upgraded. A novel concept for the L1 calorimeter trigger is introduced: the Time Multiplexed Trigger (TMT). In this design, which is similar to the CMS DAQ or High Level Trigger (HLT) architecture, nine main processors each receive all of the calorimeter data from an entire event via 18 pre-processors. The advantage of the TMT architecture is that a global view and full granularity of the calorimeters can be exploited by complex algorithms. The goal is to maintain the current thresholds for calorimeter objects and improve the performance for their selection. The introduction of new triggers based on the combination of calorimeter objects is also foreseen.
引用
收藏
页数:4
相关论文
共 6 条
[1]   The CMS experiment at the CERN LHC [J].
Chatrchyan, S. ;
Hmayakyan, G. ;
Khachatryan, V. ;
Sirunyan, A. M. ;
Adam, W. ;
Bauer, T. ;
Bergauer, T. ;
Bergauer, H. ;
Dragicevic, M. ;
Eroe, J. ;
Friedl, M. ;
Fruehwirth, R. ;
Ghete, V. M. ;
Glaser, P. ;
Hartl, C. ;
Hoermann, N. ;
Hrubec, J. ;
Haensel, S. ;
Jeitler, M. ;
Kastner, K. ;
Krammer, M. ;
de Abril, I. Magrans ;
Markytan, M. ;
Mikulec, I. ;
Neuherz, B. ;
Noebauer, T. ;
Oberegger, M. ;
Padrta, M. ;
Pernicka, M. ;
Porth, P. ;
Rohringer, H. ;
Schmid, S. ;
Schreiner, T. ;
Stark, R. ;
Steininger, H. ;
Strauss, J. ;
Taurok, A. ;
Uhl, D. ;
Waltenberger, W. ;
Walzel, G. ;
Widl, E. ;
Wulz, C. -E. ;
Petrov, V. ;
Prosolovich, V. ;
Chekhovsky, V. ;
Dvornikov, O. ;
Emeliantchik, I. ;
Litomin, A. ;
Makarenko, V. ;
Marfin, I. .
JOURNAL OF INSTRUMENTATION, 2008, 3
[2]  
CMS collaboration, CERNLHCC2013011
[3]   The MP7 and CTP-6: multi-hundred Gbps processing boards for calorimeter trigger upgrades at CMS [J].
Compton, K. ;
Dasu, S. ;
Farmahini-Farahani, A. ;
Fayer, S. ;
Fobes, R. ;
Frazier, R. ;
Gorski, T. ;
Hall, G. ;
Iles, G. ;
Jones, J. ;
Klabbers, P. ;
Newbold, D. ;
Perugupalli, A. ;
Rader, S. ;
Rose, A. ;
Seemuth, D. ;
Smith, W. ;
Tikalsky, J. .
JOURNAL OF INSTRUMENTATION, 2012, 7
[4]  
Kreis B., DP2015051 CMS
[5]  
Strebler T., CR2016129 CMS
[6]  
Zabi A., CR2015297 CMS