Fiber-optic dosimeters for radiation therapy

被引:0
|
作者
Li, Enbang [1 ]
Archer, James [1 ]
机构
[1] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
关键词
Fiber-optic dosimetry; Radiation detection; Scintillators; Cancer therapy; VIVO NEUROPHARMACOLOGY INVESTIGATIONS; INTRACEREBRAL RADIOSENSITIVE PROBE; ORGANIC SCINTILLATOR DOSIMETERS; SMALL LABORATORY-ANIMALS; ENERGY BEAM DOSIMETRY; MICROBEAM IRRADIATION; BRAIN-TUMOR; LIGHT; QUANTIFICATION; DETECTORS;
D O I
10.1117/12.2285522
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
According to the figures provided by the World Health Organization, cancer is a leading cause of death worldwide, accounting for 8.8 million deaths in 2015. Radiation therapy, which uses x-rays to destroy or injure cancer cells, has become one of the most important modalities to treat the primary cancer or advanced cancer. The newly developed microbeam radiation therapy (MRT), which uses highly collimated, quasi-parallel arrays of x-ray microbeams (typically 50 mu m wide and separated by 400 mu m) produced by synchrotron sources, represents a new paradigm in radiotherapy and has shown great promise in pre-clinical studies on different animal models. Measurements of the absorbed dose distribution of microbeams are vitally important for clinical acceptance of MRT and for developing quality assurance systems for MRT, hence are a challenging and important task for radiation dosimetry. On the other hand, during the traditional LINAC based radiotherapy and breast cancer brachytherapy, skin dose measurements and treatment planning also require a high spatial resolution, tissue equivalent, on-line dosimeter that is both economical and highly reliable. Such a dosimeter currently does not exist and remains a challenge in the development of radiation dosimetry. High resolution, water equivalent, optical and passive x-ray dosimeters have been developed and constructed by using plastic scintillators and optical fibers. The dosimeters have peak edge-on spatial resolutions ranging from 50 to 500 microns in one dimension, with a 10 micron resolution dosimeter under development. The developed fiber-optic dosimeters have been test with both LINAC and synchrotron x-ray beams. This work demonstrates that water-equivalent and high spatial resolution radiation detection can be achieved with scintillators and optical fiber systems. Among other advantages, the developed fiber-optic probes are also passive, energy independent, and radiation hard.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] Active Radiation Hardening Technology for Fiber-Optic Source
    Yang, Yuanhong
    Suo, Xinxin
    Yang, Minwei
    FOURTH ASIA PACIFIC OPTICAL SENSORS CONFERENCE, 2013, 8924
  • [22] Fiber-Optic Chemical Sensors and Fiber-Optic Bio-Sensors
    Pospisilova, Marie
    Kuncova, Gabriela
    Troegl, Josef
    SENSORS, 2015, 15 (10) : 25208 - 25259
  • [24] FIBER-OPTIC PHOTOGRAPHY
    SHERWIN, LH
    MATERIALS EVALUATION, 1985, 43 (10) : 1335 - 1335
  • [25] FIBER-OPTIC COMMUNICATIONS
    HORNAK, T
    ENGINEERING, 1978, 218 (11): : 1180 - 1182
  • [26] FIBER-OPTIC BIOSENSORS
    ANGEL, SM
    ANALYTICAL CHEMISTRY, 1988, 60 (02) : A70 - A70
  • [27] Fiber-Optic Communications
    Davis, Christopher C.
    Murphy, Thomas E.
    IEEE SIGNAL PROCESSING MAGAZINE, 2011, 28 (04) : 147 - 150
  • [28] Modulator of the polarization state of radiation for a fiber-optic communication channel
    Galkin, S.L.
    Yurkina, A.Yu.
    Kokosiiska, M.B.
    Minkov, B.I.
    Journal of Optical Technology (A Translation of Opticheskii Zhurnal), 1996, 63 (03): : 209 - 211
  • [29] Effect of external magnetic field on the collected Cherenkov radiation by fiber optic dosimeters
    Maraghechi, Borna
    Hao, Yao
    Hong, Sungje
    Li, Harold
    Mutic, Sasa
    Darafsheh, Arash
    OPTICS AND IONIZING RADIATION, 2020, 2020, 11224
  • [30] Radiation-resistance Technology for Broadband Fiber-optic Source
    Yang, Yuanhong
    Suo, Xinxin
    Yang, Minwei
    Shi, Xiaowei
    Jin, Wei
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753