ISFET glucose and sucrose sensors by using platinum electrode and photo-crosslinkable polymers

被引:54
作者
Sohn, BK
Cho, BW
Kim, CS
Kwon, DH
机构
[1] KYUNGPOOK NATL UNIV,DEPT ELECT ENGN,TAEGU 702701,SOUTH KOREA
[2] KYUNGPOOK SANUP UNIV,DEPT ELECT ENGN,KYUNGSAN GUN 713900,SOUTH KOREA
关键词
glucose sensors; ion-sensitive field-effect transistors (ISFETs); sucrose sensors; platinum electrodes; PVA-SbQ; electrolysis;
D O I
10.1016/S0925-4005(97)80271-7
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
ISFET glucose and sucrose sensors with a platinum electrode and photopolymeric enzyme membrane have been fabricated. The platinum working electrode is used for the electrolysis of hydrogen peroxide, one of the by-products of the enzyme reaction, to improve the sensing characteristics of the sensors. To improve the response time, a photo-crosslinkable polymer (PVA-SbQ) is used in the matrix for the enzyme-immobilized membrane. The characteristics of glucose and sucrose sensors are investigated according to the variation of the platinum electrode area. The response time is about 3-5 min and determination of glucose and sucrose in the range of about 30-300 mg dl(-1) is possible. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:7 / 11
页数:5
相关论文
共 11 条
[1]   AMPEROMETRIC ENZYME ELECTRODES .6. ENZYME ELECTRODES FOR SUCROSE AND LACTOSE [J].
ALBERY, WJ ;
KALIA, YN ;
MAGNER, E .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1992, 325 (1-2) :83-93
[2]  
DONG S, 1991, BIOSENS BIOELECTRON, V7, P215
[3]   RESPONSE OF AN ENZYME-MODIFIED PH-SENSITIVE ION-SELECTIVE DEVICE - EXPERIMENTAL-STUDY OF A GLUCOSE OXIDASE MODIFIED ION-SENSITIVE FIELD-EFFECT TRANSISTOR IN BUFFERED AND UNBUFFERED AQUEOUS-SOLUTION [J].
EDDOWES, MJ ;
PEDLEY, DG ;
WEBB, BC .
SENSORS AND ACTUATORS, 1985, 7 (04) :233-244
[4]   A PLANAR GLUCOSE ENZYME ELECTRODE [J].
GERNET, S ;
KOUDELKA, M ;
DEROOIJ, NF .
SENSORS AND ACTUATORS, 1989, 17 (3-4) :537-540
[5]   GLUCOSE SENSOR BASED ON A FIELD-EFFECT TRANSISTOR WITH A PHOTOLITHOGRAPHICALLY PATTERNED GLUCOSE-OXIDASE MEMBRANE [J].
HANAZATO, Y ;
NAKAKO, M ;
MAEDA, M ;
SHIONO, S .
ANALYTICA CHIMICA ACTA, 1987, 193 :87-96
[6]   MULTIENZYME ELECTRODE USING HYDROGEN-ION-SENSITIVE FIELD-EFFECT TRANSISTORS [J].
HANAZATO, Y ;
NAKAKO, M ;
SHIONO, S .
IEEE TRANSACTIONS ON ELECTRON DEVICES, 1986, 33 (01) :47-51
[7]  
KIM CS, 1993, 7 INT C SOL STAT SEN, P502
[8]  
LEE SK, 1993, P E AS C CHEM SENS F, P222
[9]   A SMART SENSOR FOR THE VOLTAMMETRIC MEASUREMENT OF OXYGEN OR GLUCOSE-CONCENTRATIONS [J].
SANSEN, W ;
DEWACHTER, D ;
CALLEWAERT, L ;
LAMBRECHTS, M ;
CLAES, A .
SENSORS AND ACTUATORS B-CHEMICAL, 1990, 1 (1-6) :298-302
[10]  
VANDENBERG A, 1991, SENSORS, V2, P489