Influence of Different Connecting Rod Configurations on the Stability of the Ilizarov/TSF Frame: A Biomechanical Study

被引:3
作者
Thiart, Gerhard [1 ,2 ]
Herbert, Christopher [3 ]
Sivarasu, Sudesh [3 ]
Gasant, Saadiq [3 ]
Laubscher, Maritz [4 ]
机构
[1] Worcester Prov Hosp, Dept Orthopaed, Worcester, Western Cape, South Africa
[2] Univ Cape Town, Groote Schuur Hosp Unit, Dept Orthopaed Res, Cape Town, Western Cape, South Africa
[3] Univ Cape Town, Dept Biomech Engn, Cape Town, Western Cape, South Africa
[4] Univ Cape Town, Groote Schuur Hosp Unit, Dept Orthopaed Res, Cape Town, Western Cape, South Africa
关键词
Connecting rod; Ilizarov technique; Stability; Stiffness; MECHANICAL PERFORMANCE; EXTERNAL FIXATION; WIRE TENSION; STIFFNESS; FIXATORS;
D O I
10.5005/jp-journals-10080-1447
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Aim: The Ilizarov external fixator (IEF) is frequently used in trauma and elective orthopaedics. Many of its biomechanical variables (ring size, wire diameter, wire number, half pins vs wires, etc.) and their influence on stability and stiffness have been investigated. There is, however, a paucity in the literature regarding the influence of the connecting rod numbers and configurations between the rings on IEF stability. The primary aim of this biomechanical study was to compare the stability between four- and three-rod IEF configurations. Secondarily to assess the difference in stability between symmetrical and asymmetrical spacing of the IEF rods. Materials and methods: A custom jig was designed to facilitate mounting of a basic two-ring IEF in a hydraulic press. Controlled centre and off-centre (thus simulated bending) axial loading was then applied across the frame. The configurations were loaded up to 4,000 N. The frame deformation was plotted and the data were then analysed and interpreted. Results: Negligible differences were observed between different four- and three-rod configurations as long as the applied force at the loading point (LP) was within the area of support (AOS) created by the rods. The different four-rod constructs were always more stable than the three-rod constructs during bending. Conclusion: There is comparable stiffness between a four-rod and a three-rod IEF construct as long as the LP is within the AOS created by the rods. A four-rod IEF is stiffer than a three-rod IEF in bending. Clinical significance: This study will possibly change some paradigms regarding the planning and application of IEFs by Orthopaedics Traumatologists and Reconstruction Surgeons.
引用
收藏
页码:23 / 27
页数:5
相关论文
共 29 条
[1]  
ARONSON J, 1992, CLIN ORTHOP RELAT R, P23
[2]   Stability of external circular fixation: a multi-variable biomechanical analysis [J].
Bronson, DG ;
Samchukov, ML ;
Birch, JG ;
Browne, RH ;
Ashman, RB .
CLINICAL BIOMECHANICS, 1998, 13 (06) :441-448
[3]   Comparison of the mechanical performance of three types of external fixators: Linear, circular and hybrid [J].
Caja, VL ;
Kim, W ;
Larsson, S ;
Chao, EYS .
CLINICAL BIOMECHANICS, 1995, 10 (08) :401-406
[4]  
Calhoun J, 1991, B HOSP JOINT DIS NEW, V52, P21
[5]  
CALHOUN JH, 1992, CLIN ORTHOP RELAT R, P15
[6]  
Claes LE, 1998, CLIN ORTHOP RELAT R, pS132
[7]   Effects of ring diameter and wire tension on the axial biomechanics of four-ring circular external skeletal fixator constructs [J].
Cross, AR ;
Lewis, DD ;
Murphy, ST ;
Rigaud, S ;
Madison, JB ;
Kehoe, MM ;
Rapoff, AJ .
AMERICAN JOURNAL OF VETERINARY RESEARCH, 2001, 62 (07) :1025-1030
[8]   Ilizarov wire tensioning and holding methods: a biomechanical study [J].
Davidson, AW ;
Mullins, M ;
Goodier, D ;
Barry, M .
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2003, 34 (02) :151-154
[9]  
Duda GN, 2000, UNFALLCHIRURG, V103, P839, DOI 10.1007/s001130050630
[10]  
FLEMING B, 1989, CLIN ORTHOP RELAT R, P95