Computer-driven automated weaning reduces weaning duration in difficult-to-wean patients

被引:11
作者
Liu Ling [1 ]
Xu Xiao-ting [1 ]
Yang Yi [1 ]
Huang Ying-zi [1 ]
Liu Song-qiao [1 ]
Qiu Hai-bo [1 ]
机构
[1] Southeast Univ, Nanjing Zhongda Hosp, Dept Crit Care Med, Nanjing 210009, Jiangsu, Peoples R China
关键词
respiration; artificial; weaning; computers; airway extubation; MECHANICAL VENTILATION; PRESSURE SUPPORT; CONTROLLED-TRIAL; EXTUBATION; OUTCOMES; MANAGEMENT;
D O I
10.3760/cma.j.issn.0366-6999.20130380
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Weaning difficulties occur in 31% of total intubated patients, and result in prolonged weaning duration. A computer-driven automated weaning system can perform a spontaneous breathing trial (SBT) automatically and display a message when the trial is successfully passed. Such a system might have a beneficial effect on difficult-to-wean patients. The aim of this study was to examine whether the computer-driven automated weaning system can accelerate discontinuation of mechanical ventilation and improve outcomes in difficult-to-wean patients. Methods This randomized controlled study included 39 difficult-to-wean patients who failed their first spontaneous breathing trial. Before initiating weaning, eligible patients were randomly allocated to wean by computer-driven automated weaning system (CDW group, n=19) or a physician-controlled local protocol (PW group, n=20). Weaning duration, defined as the time from inclusion until first extubation, was the primary endpoint. Secondary endpoints were total duration of mechanical ventilation, the length of intensive care unit (ICU) stay, the number of reintubations, the mortality rate in the ICU, the number of noninvasive ventilations, the number of complications in the ICU, and the number of ventilator-associated pneumonia cases. Results The weaning duration was reduced with the computer-driven weaning as compared with the usual protocol (median 29.0 hours vs. 45.5 hours, P=0.044). Total duration of mechanical ventilation and duration of the ICU stay did not differ between the CDW and PW groups. There was no difference in the number of reintubations between the CDW and PW groups (3 and 4 patients, P=0.732). The study groups showed comparable numbers of tracheostomy, self-extubations, ventilator-associated pneumonia, and non-invasive ventilation. Mortality in the ICU was similar in the CDW and the PW groups (21.1% vs. 20.0%, P=0.935). Conclusion The computer-driven automated weaning system can reduce weaning duration in difficult-to-wean patients as compared with a physician-controlled weaning protocol.
引用
收藏
页码:1814 / 1818
页数:5
相关论文
共 20 条
[1]   Weaning from mechanical ventilation [J].
Boles, J-M. ;
Bion, J. ;
Connors, A. ;
Herridge, M. ;
Marsh, B. ;
Melot, C. ;
Pearl, R. ;
Silverman, H. ;
Stanchina, M. ;
Vieillard-Baron, A. ;
Welte, T. .
EUROPEAN RESPIRATORY JOURNAL, 2007, 29 (05) :1033-1056
[2]   Computer-driven management of prolonged mechanical ventilation and weaning:: a pilot study [J].
Bouadma, L ;
Lellouche, F ;
Cabello, B ;
Taillé, S ;
Mancebo, J ;
Dojat, M ;
Brochard, L .
INTENSIVE CARE MEDICINE, 2005, 31 (10) :1446-1450
[3]   Implications of extubation delay in brain-injured patients meeting standard weaning criteria [J].
Coplin, WM ;
Pierson, DJ ;
Cooley, KD ;
Newell, DW ;
Rubenfeld, GD .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (05) :1530-1536
[4]   Evaluation of a knowledge-based system providing ventilatory management and decision for extubation [J].
Dojat, M ;
Harf, A ;
Touchard, D ;
Laforest, M ;
Lemaire, F ;
Brochard, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1996, 153 (03) :997-1004
[5]   Clinical evaluation of a computer-controlled pressure support mode [J].
Dojat, M ;
Harf, A ;
Touchard, D ;
Lemaire, F ;
Brochard, L .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2000, 161 (04) :1161-1166
[6]   Effect on the duration of mechanical ventilation of identifying patients capable of breathing spontaneously [J].
Ely, EW ;
Baker, AM ;
Dunagan, DP ;
Burke, HL ;
Smith, AC ;
Kelly, PT ;
Johnson, MM ;
Browder, RW ;
Bowton, DL ;
Haponik, EF .
NEW ENGLAND JOURNAL OF MEDICINE, 1996, 335 (25) :1864-1869
[7]   Characteristics and outcomes in adult patients receiving mechanical ventilation -: A 28-day international study [J].
Esteban, A ;
Anzueto, A ;
Frutos, F ;
Alía, I ;
Brochard, L ;
Stewart, TE ;
Benito, S ;
Epstein, SK ;
Apezteguía, C ;
Nightingale, P ;
Arroliga, AC ;
Tobin, MJ .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2002, 287 (03) :345-355
[8]   MODES OF MECHANICAL VENTILATION AND WEANING - A NATIONAL SURVEY OF SPANISH HOSPITALS [J].
ESTEBAN, A ;
ALIA, I ;
IBANEZ, J ;
BENITO, S ;
TOBIN, MJ ;
ALVAREZ, B ;
BLANCH, L ;
BLANCO, JL ;
BONET, A ;
CABRE, L ;
DELACAL, MA ;
CAMBRONERO, J ;
DIAZPRIETO, A ;
FONSECA, F ;
FONTANEDA, D ;
FRUTOS, M ;
GARCIA, A ;
GENER, J ;
GINESTAL, R ;
GONZALEZ, G ;
GUDIN, J ;
GUERRERO, JE ;
GUIRADO, M ;
HONRUBIA, I ;
IRURETAGOYENA, JR ;
ITURBE, F ;
JARENO, A ;
JIMENEZ, J ;
LACORT, M ;
LATORRE, F ;
LOPEZMESSA, JB ;
MARTIN, JC ;
MARTINEZ, JR ;
MONEDERO, P ;
MUNOZ, T ;
DELNOGAL, F ;
NOLLA, J ;
PALAZON, E ;
PEREZARANCON, JL ;
PONS, A ;
REYES, A ;
ROIG, M ;
ROMERA, MA ;
RUBIO, J ;
SERRANO, JM ;
SOLSONA, JF ;
SUAREZ, R ;
TABOADA, F ;
DELATORRE, F ;
VALLVERDU, I .
CHEST, 1994, 106 (04) :1188-1193
[9]   A prospective, controlled trial of a protocol-based strategy to discontinue mechanical ventilation [J].
Krishnan, JA ;
Moore, D ;
Robeson, C ;
Rand, CS ;
Fessler, HE .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 169 (06) :673-678
[10]   A multicenter randomized trial of computer-driven protocolized weaning from mechanical ventilation [J].
Lellouche, Francois ;
Mancebo, Jordi ;
Jolliet, Philippe ;
Roeseler, Jean ;
Schortgen, Frederique ;
Dojat, Michel ;
Cabello, Belen ;
Bouadma, Lila ;
Rodriguez, Pablo ;
Maggiore, Salvatore ;
Reynaert, Marc ;
Mersmann, Stefan ;
Brochard, Laurent .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2006, 174 (08) :894-900