Improving the diagnostic yield of single-operator cholangioscopy-guided biopsy of indeterminate biliary strictures: ROSE to the rescue? (with video)

被引:48
作者
Varadarajulu, Shyam [1 ]
Bang, Ji Young [2 ]
Hasan, Muhammad K. [1 ]
Navaneethan, Udayakumar [1 ]
Hawes, Robert [1 ]
Hebert-Magee, Shantel [1 ]
机构
[1] Florida Hosp, Ctr Intervent Endoscopy, 601 East Rollins St, Orlando, FL 32803 USA
[2] Indiana Univ, Div Gastroenterol Hepatol, Indianapolis, IN 46204 USA
关键词
FINE-NEEDLE-ASPIRATION; CHRONIC-PANCREATITIS; EUS-FNA; CHOLANGIOCARCINOMA; ACCURACY; CYTOLOGY; METAANALYSIS; MASSES; SYSTEM; TRACT;
D O I
10.1016/j.gie.2016.03.1497
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: Tissue diagnosis, regardless of technique or endoscope used, can be challenging in patients with indeterminate biliary strictures (IDBSs). This exploratory study evaluated the utility and role of rapid onsite evaluation of touch imprint cytology (ROSE-TIC) when single-operator cholangioscopy (SOC)-guided biopsies of IDBSs are performed. Methods: Patients with IDBSs were evaluated by intraprocedural ROSE-TIC during SOC-guided biopsy procedures. Final diagnosis was established by long-term patient follow-up in conjunction with off-site findings or surgical histology. The main outcome measure was to evaluate the utility of ROSE-TIC by determination of its operating characteristics and comparison with off-site histologic assessment. Results: Of 31 patients with IDBSs, tissue diagnosis was indeterminate at prior ERCP-guided brush and/or biopsy in 14, prior EUS-guided FNA (EUS-FNA) in 6, and a mass could not be identified at EUS in 11. The mean number of biopsies performed was 3.3 (range 1-8), and diagnostic interpretation by ROSE-TIC was diagnostic and/or suspicious for carcinoma in 15, benign in 13, atypical-reactive in 2, and bile duct intraductal papillary mucinous neoplasm in 1. Final diagnosis by surgical histology (n = 4), death by disease (n = 10), and patient follow-up (n = 17) showed that the overall sensitivity of ROSE-TIC for diagnosing malignancy was 100%, specificity 88.9%, positive predictive value 86.7%, negative predictive value 100%, and diagnostic accuracy 93.5%. Conclusions: Preliminary data suggest that the diagnostic outcomes of SOC-guided biopsies in IDBSs can be significantly improved by using ROSE-TIC. This technique also may benefit centers that rely mainly on fluoroscopy-guided intraductal biopsies.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 20 条
  • [1] Does onsite cytotechnology evaluation improve the accuracy of endoscopic ultrasound-guided fine-needle aspiration biopsy?
    Alsohaibani, Fahad
    Girgis, Safwat
    Sandha, Gurpal Singh
    [J]. CANADIAN JOURNAL OF GASTROENTEROLOGY AND HEPATOLOGY, 2009, 23 (01) : 26 - 30
  • [2] SpyGlass single-operator peroral cholangiopancreatoscopy system for the diagnosis and therapy of bile-duct disorders: a clinical feasibility study (with video)
    Chen, Yang K.
    Pleskow, Douglas K.
    [J]. GASTROINTESTINAL ENDOSCOPY, 2007, 65 (06) : 832 - 841
  • [3] Grading the complexity of endoscopic procedures: results of an ASGE working party
    Cotton, Peter B.
    Eisen, Glenn
    Romagnuolo, Joseph
    Vargo, John
    Baron, Todd
    Tarnasky, Paul
    Schutz, Steve
    Jacobson, Brian
    Bott, Chris
    Petersen, Bret
    [J]. GASTROINTESTINAL ENDOSCOPY, 2011, 73 (05) : 868 - 874
  • [4] COMPARING THE AREAS UNDER 2 OR MORE CORRELATED RECEIVER OPERATING CHARACTERISTIC CURVES - A NONPARAMETRIC APPROACH
    DELONG, ER
    DELONG, DM
    CLARKEPEARSON, DI
    [J]. BIOMETRICS, 1988, 44 (03) : 837 - 845
  • [5] Biliary Multifocal Chromosomal Polysomy and Cholangiocarcinoma in Primary Sclerosing Cholangitis
    Eaton, John E.
    Fritcher, Emily G. Barr
    Gores, Gregory J.
    Atkinson, Elizabeth J.
    Tabibian, James H.
    Topazian, Mark D.
    Gossard, Andrea A.
    Halling, Kevin C.
    Kipp, Benjamin R.
    Lazaridis, Konstantinos N.
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2015, 110 (02) : 299 - 309
  • [6] Fritscher-Ravens A, 2002, AM J GASTROENTEROL, V97, P2768
  • [7] Fujii Larissa L, 2014, Gastrointest Endosc Clin N Am, V24, P125, DOI 10.1016/j.giec.2013.08.003
  • [8] The presence of a cytopathologist increases the diagnostic accuracy of endoscopic ultrasound-guided fine needle aspiration cytology for pancreatic adenocarcinoma: a meta-analysis
    Hebert-Magee, S.
    Bae, S.
    Varadarajulu, S.
    Ramesh, J.
    Frost, A. R.
    Eloubeidi, M. A.
    Eltoum, I. A.
    [J]. CYTOPATHOLOGY, 2013, 24 (03) : 159 - 171
  • [9] Influence of On-Site Cytopathology Evaluation on the Diagnostic Accuracy of Endoscopic Ultrasound-Guided Fine Needle Aspiration (EUS-FNA) of Solid Pancreatic Masses
    Iglesias-Garcia, Julio
    Enrique Dominguez-Munoz, J.
    Abdulkader, Ihab
    Larino-Noia, Jose
    Eugenyeva, Elena
    Lozano-Leon, Antonio
    Forteza-Vila, Jeronimo
    [J]. AMERICAN JOURNAL OF GASTROENTEROLOGY, 2011, 106 (09) : 1705 - 1710
  • [10] Pathogenesis, Diagnosis, and Management of Cholangiocarcinoma
    Ilyas, Sumera I.
    Gores, Gregory J.
    [J]. GASTROENTEROLOGY, 2013, 145 (06) : 1215 - 1229