Marginal accuracy of combined tooth-implant-supported fixed dental prostheses after in vitro stress simulation

被引:6
|
作者
Boeckler, Arne F. [1 ]
Morton, Dean [2 ]
Kraemer, Stephan [1 ]
Geiss-Gerstdorfer, Juergen [3 ]
Setz, Juergen M. [1 ]
机构
[1] Univ Halle Wittenberg, Dept Prosthodont, D-06108 Halle, Saale, Germany
[2] Univ Florida, Ctr Implant Dent, Gainesville, FL USA
[3] Univ Hosp Tuebingen, Ctr Dent & Oral Med, Dept Med Mat & Technol, Tubingen, Germany
关键词
abutment teeth; cement; implant; marginal gap; tooth-implant-supported FDPs;
D O I
10.1111/j.1600-0501.2008.01593.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Caries, periodontal disease, and peri-implant inflammation caused by deficient marginal adaptation of fixed prostheses are reasons for clinical failure of combined tooth-implant-supported fixed dental prostheses (TISFDP). This in vitro study examined the marginal accuracy in TISFDP after simulated stress in an artificial oral environment. Twelve three-unit TISFDPs were fabricated using a high noble alloy on models containing a human premolar with an artificial periodontium and an implant. Four three-unit tooth-supported prostheses (TSFDP) represented the control group. The experimental TISFDPs (four per group) were luted with three different cements: group 1, zinc phosphate; group 2, glass ionomer; group 3, self-adhesive resin. The specimens were mechanically loaded (1.2 million cycles/50 N) and thermally cycled (8000 cycles with 5/55 degrees C). The vertical marginal gap was measured before and after cementation, after chewing simulation and after thermal cycling by light microscopy (x 560). The results were subjected to statistical analysis (t-test/one-way analysis of variance/Bonferroni). Significant increase (P <= 0.05) in the marginal gap was found after cementation within the experimental TISFDPs (implants, 11.7-18.7 mu m; teeth, 13.4-24.2 mu m) and the control TSFDPs (28.5 mu m). Comparison of groups 1 and 2 revealed significant differences for the teeth while comparison of the implants showed significant differences among all groups. Chewing simulation and thermal cycling caused statistically insignificant changes in the marginal gaps of the experimental as well as the control TSFDPs. The cementation of the TISFDPs with different luting materials caused a specific enlargement of the marginal gap in teeth and implants. Subsequent to simulated oral stress in an artificial oral environment, no significant changes of the marginal accuracy could be found. To cite this article:Boeckler AF, Morton D, Kraemer S, Geiss-Gerstdorfer J, Setz JM. Marginal accuracy of combined tooth-implant-supported fixed dental prostheses after in vitro stress simulation.Clin. Oral Impl. Res. 19, 2008; 1261-1269doi: 10.1111/j.1600-0501.2008.01593.x.
引用
收藏
页码:1261 / 1269
页数:9
相关论文
共 50 条
  • [1] Short-term complications of implant-supported and combined tooth-implant-supported fixed dental prostheses
    Rammelsberg, Peter
    Schwarz, Stefanie
    Schroeder, Christin
    Bermejo, Justo L.
    Gabbert, Olaf
    CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (07) : 758 - 762
  • [2] Tooth-implant-supported fixed dental prostheses for the replacement of missing teeth
    von Stein-Lausnitz, Manja
    Sterzenbach, Guido
    Nickenig, Hans-Joachim
    Wolfart, Stefan
    Beuer, Florian
    IMPLANTOLOGIE, 2020, 28 (03): : 257 - 264
  • [3] Analysis of technical complications and risk factors for failure of combined tooth-implant-supported fixed dental prostheses
    Chrcanovic, Bruno Ramos
    Kisch, Jeno
    Larsson, Christel
    CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2020, 22 (04) : 523 - 532
  • [4] Fracture behavior of all-ceramic, implant-supported, and tooth-implant-supported fixed dental prostheses
    Alkharrat, Abdul Rahman
    Schmitter, Marc
    Rues, Stefan
    Rammelsberg, Peter
    CLINICAL ORAL INVESTIGATIONS, 2018, 22 (04) : 1663 - 1673
  • [5] Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result
    Beuer, Florian
    Sachs, Caroline
    Groesser, Julian
    Gueth, Jan-Frederik
    Stimmelmayr, Michael
    CLINICAL ORAL INVESTIGATIONS, 2016, 20 (05) : 1079 - 1086
  • [6] Tooth-implant-supported posterior fixed dental prostheses with zirconia frameworks: 3-year clinical result
    Florian Beuer
    Caroline Sachs
    Julian Groesser
    Jan-Frederik Gueth
    Michael Stimmelmayr
    Clinical Oral Investigations, 2016, 20 : 1079 - 1086
  • [7] Bone loss of immediately loaded implants with implant-supported and tooth-implant-supported fixed maxillary prostheses
    Heinemann, Friedhelm
    Mundt, Torsten
    Schwahn, Christian
    Hasan, Istabrak
    BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2012, 57 (01): : 33 - 38
  • [8] Long-term chipping and failure rates of implant-supported and combined tooth-implant-supported metal-ceramic and ceramic fixed dental prostheses: A cohort study
    Rammelsberg, Peter
    Meyer, Andre
    Lorenzo-Bermejo, Justo
    Kappel, Stefanie
    Zenthoefer, Andreas
    JOURNAL OF PROSTHETIC DENTISTRY, 2021, 126 (02): : 196 - 203
  • [9] Long-term outcomes and complication rates of tooth-implant-supported fixed dental prostheses: A retrospective cohort study
    Dahlgren, Simon
    Johansson, Carin Starkhammar
    Sayardoust, Shariel
    JOURNAL OF PROSTHODONTICS-IMPLANT ESTHETIC AND RECONSTRUCTIVE DENTISTRY, 2024,
  • [10] Survival and complication rates of combined tooth-implant-supported fixed partial dentures
    Nickenig, Hans-Joachim
    Schaefer, Corinna
    Spiekermann, Hubertus
    CLINICAL ORAL IMPLANTS RESEARCH, 2006, 17 (05) : 506 - 511