Study of mist-cooling for semi-enclosed spaces in Osaka, Japan

被引:31
作者
Farnham, Craig [1 ]
Nakao, Masaki [1 ]
Nishioka, Masatoshi [1 ]
Nabeshima, Minako [1 ]
Mizuno, Takeo [2 ]
机构
[1] Osaka City Univ, Grad Sch Engn, 3-3-138 Sugimoto, Osaka 5588585, Japan
[2] H Ikeuchi Co Ltd, Chuo Ku, Osaka 5500011, Japan
来源
URBAN ENVIRONMENTAL POLLUTION 2010 | 2011年 / 4卷
关键词
mist; evaporative cooling; heat island; spray nozzle; urban spaces;
D O I
10.1016/j.proenv.2011.03.027
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Evaporative mist cooling systems are increasingly used in Japan to cool urban spaces as a counter to the urban heat island problem. Japan has a humid climate, which reduces evaporation. The balance between cooling and undesirable wetting requires careful control and placement of misting nozzles. Spraying from varying heights in an atrium showed that a single spray nozzle with Sauter mean droplet diameter of 41 microns can provide cooling of 0.7K without wetting. Cooling effects of mists with larger droplet diameters that cause slight wetting cannot be accurately measured due to the wet bulb effect on the sensors. Simulations suggest actual air temperatures are higher than wet sensor readings. Calculations of effective temperature ET* show that increases in humidity do not overcome the increase in thermal comfort due to the temperature reductions from fine mist. (C) 2009 Published by Elsevier BV
引用
收藏
页码:228 / 238
页数:11
相关论文
共 12 条
[1]  
Alvarez S., 1991, ARCHITECTURE URBAN S, P619
[2]  
[Anonymous], 1998, Microphysics of clouds and precipitation
[3]  
*ASHRAE, 2005, ASHRAE HDB FUND, pCH8
[4]  
Farnham Craig, 2009, Transactions of the Japan Society of Refrigerating and Air Conditioning Engineers, V26, P105
[5]  
Japan Building Mechanical and Electrical Engineers Assoc, 1992, HASP ACSS 8502 PROGR
[6]   SUSCEPTIBILITY OF LEGIONELLA-PNEUMOPHILA TO CHLORINE IN TAP WATER [J].
KUCHTA, JM ;
STATES, SJ ;
MCNAMARA, AM ;
WADOWSKY, RM ;
YEE, RB .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1983, 46 (05) :1134-1139
[7]  
Osaka City Waterworks Bureau, 2008, WAT QUAL MAN
[8]   Refining the use of evaporation in an experimental down-draft cool tower [J].
Pearlmutter, D ;
Erell, E ;
Etzion, Y ;
Meir, IA ;
Di, H .
ENERGY AND BUILDINGS, 1996, 23 (03) :191-197
[9]   Updated world map of the Koppen-Geiger climate classification [J].
Peel, M. C. ;
Finlayson, B. L. ;
McMahon, T. A. .
HYDROLOGY AND EARTH SYSTEM SCIENCES, 2007, 11 (05) :1633-1644
[10]  
Uchiyama S, 2008, JAPAN SOC PLUMBING E, V25, P2