Global Water Flow Measurement and Calibration Facilities: Review of Methods and Instrumentations

被引:14
作者
Jaiswal, S. K. [1 ]
Yadav, S. [1 ]
Bandyopadhyay, A. K. [1 ]
Agarwal, R. [2 ]
机构
[1] India CSIR NPLI, CSIR Natl Phys Lab, New Delhi 110012, India
[2] Thapar Univ, Patiala 147004, Punjab, India
来源
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA | 2012年 / 27卷 / 02期
关键词
Water flow calibration facility (WFCF); Weighing method; Volumetric method; Measurement error and uncertainty; Diverter; Calibration and measurement capability (CMC); SYSTEM; STANDARD;
D O I
10.1007/s12647-012-0017-x
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Water Flow Calibration Facilities (WFCFs) are widely used for the calibration of water flowmeters all over the world. Last two decades have witnessed significant research contributions in the development of instrumentation and techniques with special emphasis on reducing the measurement errors and improving the measurement uncertainty in flow calibration. It is difficult to find a consolidated report/review of such developments for the new entrants/researchers/metrologists in this field. Therefore, authors considered that it is high time to review the literature and compile a concise report to this effect. Present paper is an attempt to publish terse review on the historical background, recent developments and current status of WFCF and related works. The work going on at National Physical Laboratory, India, in this direction is also briefly described.
引用
收藏
页码:63 / 76
页数:14
相关论文
共 34 条
[1]  
[Anonymous], 1980, 4185 ISO, P1
[2]  
[Anonymous], 1990, 93681 ISO, P1
[3]  
[Anonymous], 2005, 4149 ISO, P1
[4]  
[Anonymous], 2006, NIST SPECIAL PUBLICA, V250
[5]  
[Anonymous], 2008, Evaluation of measurement data Guide to the expression of uncertainty in measurement, DOI DOI 10.1373/CLINCHEM.2003.030528
[6]  
Bair M., 1999, P NCSLI 1999 WORKSH
[7]   Bell Prover - Calibration and Monitoring of Time Stability [J].
Benkova, Miroslava ;
Makovnik, Stefan ;
Mikulecky, Ivan ;
Zamecnik, Vlastimil .
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2011, 26 (03) :165-171
[8]   Performance of a Gas Flow Meter Calibration System Utilizing Critical Flow Venturi Standards [J].
Carter, Michael ;
Johansen, William ;
Britton, Charles .
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2011, 26 (03) :247-254
[9]   Novel Water Flow Facility in France Range Extension to Low Flow Rates (10 000 ml/h down to 1 ml/h) [J].
David, Christopher ;
Claudel, Pierre .
MAPAN-JOURNAL OF METROLOGY SOCIETY OF INDIA, 2011, 26 (03) :203-209
[10]   Development of weighing tank system employing rotating double wing diverter [J].
Doihara, R ;
Shimada, T ;
Terao, Y ;
Takamoto, M .
FLOW MEASUREMENT AND INSTRUMENTATION, 2006, 17 (03) :141-152