Fast Three-Dimensional Inner Volume Excitations Using Parallel Transmission and Optimized k-Space Trajectories

被引:15
作者
Davids, Mathias [1 ,2 ]
Schad, Lothar R. [1 ]
Wald, Lawrence L. [2 ,3 ,4 ]
Guerin, Bastien [2 ,4 ]
机构
[1] Heidelberg Univ, Med Fac Mannheim, Comp Assisted Clin Med, Theodor Kutzer Ufer 1-3, D-68167 Mannheim, BW, Germany
[2] Massachusetts Gen Hosp, Dept Radiol, AA Martinos Ctr Biomed Imaging, Charlestown, MA USA
[3] Harvard MIT, Div Hlth Sci & Technol, Cambridge, MA USA
[4] Harvard Med Sch, Boston, MA USA
关键词
Parallel transmit; spatially selective excitation; inner volume excitation; B0; robustness; k-space trajectory optimization; GRADIENT WAVE-FORMS; RF PULSES; DESIGN; ECHOES; BRAIN;
D O I
10.1002/mrm.26021
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To design short parallel transmission (pTx) pulses for excitation of arbitrary three-dimensional (3D) magnetization patterns. Methods: We propose a joint optimization of the pTx radiofrequency (RF) and gradient waveforms for excitation of arbitrary 3D magnetization patterns. Our optimization of the gradient waveforms is based on the parameterization of k-space trajectories (3D shells, stack-of-spirals, and cross) using a small number of shape parameters that are well-suited for optimization. The resulting trajectories are smooth and sample k-space efficiently with few turns while using the gradient system at maximum performance. Within each iteration of the k-space trajectory optimization, we solve a small tip angle least-squares RF pulse design problem. Our RF pulse optimization framework was evaluated both in Bloch simulations and experiments on a 7T scanner with eight transmit channels. Results: Using an optimized 3D cross (shells) trajectory, we were able to excite a cube shape (brain shape) with 3.4% (6.2%) normalized root-mean-square error in less than 5 ms using eight pTx channels and a clinical gradient system (G(max) = 40 mT/m, S-max = 150 T/m/s). This compared with 4.7% (41.2%) error for the unoptimized 3D cross (shells) trajectory. Incorporation of B-0 robustness in the pulse design significantly altered the k-space trajectory solutions. Conclusion: Our joint gradient and RF optimization approach yields excellent excitation of 3D cube and brain shapes in less than 5 ms, which can be used for reduced field of view imaging and fat suppression in spectroscopy by excitation of the brain only. (C) 2015 Wiley Periodicals, Inc.
引用
收藏
页码:1170 / 1182
页数:13
相关论文
共 32 条
  • [1] Börnert P, 1998, MAGN RESON MATER PHY, V7, P166
  • [2] SPATIAL LOCALIZATION IN NMR-SPECTROSCOPY INVIVO
    BOTTOMLEY, PA
    [J]. ANNALS OF THE NEW YORK ACADEMY OF SCIENCES, 1987, 508 : 333 - 348
  • [3] Chen D., 2009, Proceedings of the 17th Scientific Meeting, P171
  • [4] Davids M, 2015, P 23 ANN M ISMRM TOR, P551
  • [5] Davids M, 2014, P INT SOC MAG RESON, P1452
  • [6] Davids M., 2014, P INT SOC MAG RESON, V22, P943
  • [7] Fast and Robust Design of Time-Optimal k-Space Trajectories in MRI
    Davids, Mathias
    Ruttorf, Michaela
    Zoellner, Frank G.
    Schad, Lothar R.
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 564 - 577
  • [8] Deniz C. M., 2013, P INT SOC MAG RESON, V21, P4434
  • [9] Fautz HP., 2008, P 16 ANN M ISMRM ISM, P1247
  • [10] STIMULATED ECHO IMAGING
    FRAHM, J
    MERBOLDT, KD
    HANICKE, W
    HAASE, A
    [J]. JOURNAL OF MAGNETIC RESONANCE, 1985, 64 (01) : 81 - 93