Linear thermal expansion coefficient of silicon from 293 to 1000 K

被引:346
作者
Watanabe, H
Yamada, N
Okaji, M
机构
[1] Natl Metrol Inst Japan, AIST, Thermophys Properties Sect, Tsukuba, Ibaraki 3058563, Japan
[2] AIST, Int Affairs Dept, Tsukuba, Ibaraki 3058563, Japan
关键词
gold versus platinum thermocouple; heterodyne interferometer; reference material; silicon; standard reference data; thermal expansion;
D O I
10.1023/B:IJOT.0000022336.83719.43
中图分类号
O414.1 [热力学];
学科分类号
摘要
As a part of the program to establish a thermal expansion standard, the linear thermal expansion coefficients of single-crystal silicon have been determined in the temperature range 293 to 1000 K using a dilatometer which consists of a heterodyne laser Michelson interferometer and gold versus platinum thermo-couple. The relative standard deviation of the measured values from those calculated from the best least-squares fit was 0.21%. The relative expanded uncertainty in the measurement was estimated to be 1.1 to 1.5% in the temperature range, based upon an analysis of thirteen standard uncertainties. The present data are compared with the data previously obtained by similar dilatometers and the standard reference data for the thermal expansion coefficient of silicon, recommended by the Committee on Data for Science and Technology (CODATA). The present data are in good agreement with the most recently reported data but not with the earlier high-temperature data used to evaluate the standard reference data, which suggests a need for the reevaluation of the standard reference data for the thermal expansion coefficient of silicon at temperatures above 600 K.
引用
收藏
页码:221 / 236
页数:16
相关论文
共 9 条
[2]   A HIGH-TEMPERATURE DILATOMETER USING OPTICAL HETERODYNE INTERFEROMETRY [J].
OKAJI, M ;
IMAI, H .
JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1987, 20 (07) :887-891
[3]  
OKAJI M, 1985, PRECIS ENG, V7, P206
[4]   RECOMMENDED VALUES FOR THE THERMAL EXPANSIVITY OF SILICON FROM 0-K TO 1000-K [J].
SWENSON, CA .
JOURNAL OF PHYSICAL AND CHEMICAL REFERENCE DATA, 1983, 12 (02) :179-182
[5]   LINEAR INTERPOLATION OF PERIODIC ERROR IN A HETERODYNE LASER INTERFEROMETER AT SUBNANOMETER LEVELS [J].
TANAKA, M ;
YAMAGAMI, T ;
NAKAYAMA, K .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (02) :552-554
[6]   Development of a laser interferometric dilatometer for measurements of thermal expansion of solids in the temperature range 300 to 1300 K [J].
Watanabe, H ;
Yamada, N ;
Okaji, M .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2002, 23 (02) :543-554
[7]   Laser interferometric dilatometer applicable to temperature range from 1300 to 2000 K [J].
Watanabe, H ;
Yamada, N ;
Okaji, M .
INTERNATIONAL JOURNAL OF THERMOPHYSICS, 2001, 22 (04) :1185-1200
[8]  
White GK, 1998, CINDAS DATA, VI-4, P269
[9]  
YAMADA N, 1997, HIGH TEMP HIGH PRESS, V29, P89