Comparative study based on energy and exergy analyses of a baffled solar air heater with latent storage collector

被引:95
作者
Ghiami, Amir [2 ]
Ghiami, Shamsoddin [1 ]
机构
[1] Univ Leeds, Sch Chem & Proc Engn, Fac Engn, Leeds, W Yorkshire, England
[2] Karlsruhe Inst Technol, Inst Microproc Engn IMVT, Hermann Von Helmholtz Pl 1, D-76344 Eggenstein Leopoldshafe, Germany
关键词
Energy efficiency; Exergy efficiency; Phase Change Material (PCM); Solar Air Heater (SAH); Baffles; PHASE-CHANGE MATERIAL; THERMOHYDRAULIC PERFORMANCE; TRANSFER ENHANCEMENT; THERMAL PERFORMANCE; FLAT; SINGLE; FLOW;
D O I
10.1016/j.applthermaleng.2017.11.111
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this empirical study, exergy and energy investigation of a novel solar air heater (SAH) was undertaken in presence of the paraffin wax slab as the Phase-Change-Material (PCM). Characteristics of the system was scrutinized in presence and absence of baffle on the absorber plate. In the experimental study, two types of baffle-equipped and an unequipped absorber plate were inspected in presence of PCM unit and their exergy and efficiency were compared. For the baffled absorber plates, the baffles are made of galvanized plates and are arranged in sequential or staggered manner. At three different air mass flow rates of 0.017 Kg/s, 0.014 Kg/s and 0.009 Kg/s, inlet, PCM and outlet temperature were measured and compared. Exploiting the 1st and 2nd thermodynamics laws, the exergy and energy efficiencies were calculated. This study's outcome approved that, at different air mass flow rates, the baffle-equipped SAH obtained the highest efficiencies while the unequipped one has the lowest. It has been found out that, at the mass flow rate of 0.017 Kg/s, the maximum energy efficiency was attained for sequence arranged baffle-equipped SAH (26.78%), while unequipped SAH had the least energy efficiency (14.30%) at the same mass flow rate. The exergy efficiencies varied between 4.86 - 20.47% for all cases of study. (C) 2017 Elsevier Ltd. All rights reserved.
引用
收藏
页码:797 / 808
页数:12
相关论文
共 43 条
[1]   Heat transfer and friction characteristics of solar air heater ducts having integral inclined discrete ribs on absorber plate [J].
Aharwal, K. R. ;
Gandhi, Bhupendra K. ;
Saini, J. S. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2009, 52 (25-26) :5970-5977
[2]   Experimental investigation on heat transfer enhancement due to V-shaped perforated blocks in a rectangular duct of solar air heater [J].
Alam, Tabish ;
Saini, R. P. ;
Saini, J. S. .
ENERGY CONVERSION AND MANAGEMENT, 2014, 81 :374-383
[3]   2ND LAW OPTIMIZATION OF FLAT-PLATE SOLAR AIR HEATERS .1. THE CONCEPT OF NET EXERGY FLOW AND THE MODELING OF SOLAR AIR HEATERS [J].
ALTFELD, K ;
LEINER, W ;
FIEBIG, M .
SOLAR ENERGY, 1988, 41 (02) :127-132
[4]  
[Anonymous], 1993, SOLAR ENERGY
[5]   Energy and exergy analyses of porous baffles inserted solar air heaters for building applications [J].
Bayrak, Fatih ;
Oztop, Hakan F. ;
Hepbasli, Arif .
ENERGY AND BUILDINGS, 2013, 57 :338-345
[6]   Energy and exergy analysis of a new solar air heater with latent storage energy [J].
Bouadila, Salwa ;
Lazaar, Mariem ;
Skouri, Safa ;
Kooli, Sami ;
Farhat, Abdelhamid .
INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2014, 39 (27) :15266-15274
[7]   Performance of a new solar air heater with packed-bed latent storage energy for nocturnal use [J].
Bouadila, Salwa ;
Kooli, Sami ;
Lazaar, Mariem ;
Skouri, Safa ;
Farhat, Abdelhamid .
APPLIED ENERGY, 2013, 110 :267-275
[8]  
CHURCHILL SW, 1975, INT J HEAT MASS TRAN, V18, P1323, DOI [10.1016/0017-9310(75)90243-4, 10.1016/0017-9310(75)90222-7]
[9]   COOKING DURING OFF-SUNSHINE HOURS USING PCMS AS STORAGE MEDIA [J].
DOMANSKI, R ;
ELSEBAII, AA ;
JAWORSKI, M .
ENERGY, 1995, 20 (07) :607-616
[10]  
Duffle J.A., 1991, SOLAR ENG THERMAL PR