Hemodynamics of 8 Different Configurations of Stenting for Bifurcation Aneurysms

被引:82
作者
Kono, K. [1 ]
Terada, T. [1 ]
机构
[1] Wakayama Rosai Hosp, Dept Neurosurg, Wakayama 6408505, Japan
关键词
ASSISTED COIL EMBOLIZATION; BASILAR TIP ANEURYSMS; INTRACRANIAL ANEURYSMS; ENDOVASCULAR TREATMENT; Y-CONFIGURATION; FLUID-DYNAMICS; CEREBRAL ANEURYSMS; TECHNICAL NOTE; APEX ANEURYSM; PLACEMENT;
D O I
10.3174/ajnr.A3479
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: SACE is performed for complex aneurysms. There are several configurations of stent placement for bifurcation aneurysms. We investigated hemodynamics among 8 different configurations of stent placement, which may relate to the recanalization rate. MATERIALS AND METHODS: We created a silicone block model of a patient-specific asymmetric bifurcation aneurysm. Enterprise closed-cell stents were deployed in the model as various configurations. 3D images of these stents were obtained by micro-CT. We performed CFD simulations for a no-stent model and 8 stent models: a single stent from a proximal vessel to a right or left distal vessel, a horizontal stent, a kissing-Y stent with a uniformly narrowed structure, a nonoverlapping-Y stent, a virtual-Y stent with no narrowed structure (fusion of 2 single stents), and 2 different crossing-Y stents with a focally narrowed structure. Hemodynamic parameters were evaluated. RESULTS: Cycle-averaged velocity and WSS in the aneurysm were reduced because of stent placement in the following order: single stent (19% reduction in cycle-averaged velocity) < nonoverlapping-Y stent (29%) < virtual-Y stent (32%) < horizontal stent (39%) < kissing-Y stent (48%) < crossing-Y stent (54%). Kissing-and crossing-Y stents redirected impingement flow into the distal vessels because of lowered porosity of stents due to narrowed structures. CONCLUSIONS: Among 8 different configurations of stent placement, kissing-and crossing-Y stents showed the strongest reduction in flow velocity in the aneurysm because of lowered porosity of stents and redirection of impingement flow. This may be a desirable reconstruction of flow hemodynamics and may decrease recanalization rates in SACE.
引用
收藏
页码:1980 / 1986
页数:7
相关论文
共 33 条
[1]   Y-Stent-Assisted Coil Embolization of Wide-Neck Intracranial Aneurysms A Single Center Experience [J].
Akgul, E. ;
Aksungur, E. ;
Balli, T. ;
Onan, B. ;
Yilmaz, D. M. ;
Bicakci, S. ;
Erman, T. .
INTERVENTIONAL NEURORADIOLOGY, 2011, 17 (01) :36-48
[2]   Influence of stent configuration on cerebral aneurysm fluid dynamics [J].
Babiker, M. Haithem ;
Gonzalez, L. Fernando ;
Ryan, Justin ;
Albuquerque, Felipe ;
Collins, Daniel ;
Elvikis, Arius ;
Frakes, David H. .
JOURNAL OF BIOMECHANICS, 2012, 45 (03) :440-447
[3]   "Double-Barrel" Stent Reconstruction of a Symptomatic Fusiform Basilar Artery Aneurysm: Case Report [J].
Bain, Mark ;
Hussain, Muhammad Shazam ;
Spiotta, Alejandro ;
Gonugunta, Vivekananda ;
Moskowitz, Shaye ;
Gupta, Rishi .
NEUROSURGERY, 2011, 68 (05) :E1491-E1496
[4]   Hemodynamic changes due to stent placement in bifurcating intracranial aneurysms [J].
Cantón, G ;
Levy, DI ;
Lasheras, JC .
JOURNAL OF NEUROSURGERY, 2005, 103 (01) :146-155
[5]  
Castro MA, 2006, AM J NEURORADIOL, V27, P1703
[6]   Novel "Y" Stent Flow Diversion Technique for the Endovascular Treatment of Bifurcation Aneurysms without Endosaccular Coiling [J].
Cekirge, H. S. ;
Yavuz, K. ;
Geyik, S. ;
Saatci, I. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (07) :1262-1268
[7]   Safety and Efficacy of Endovascular Treatment of Basilar Tip Aneurysms by Coiling With and Without Stent Assistance: A Review of 235 Cases [J].
Chalouhi, Nohra ;
Jabbour, Pascal ;
Gonzalez, L. Fernando ;
Dumont, Aaron S. ;
Rosenwasser, Robert ;
Starke, Robert M. ;
Gordon, David ;
Hann, Shannon ;
Tjoumakaris, Stavropoula .
NEUROSURGERY, 2012, 71 (04) :785-794
[8]   Nonoverlapping Y-Configuration Stenting Technique With Dual Closed-Cell Stents in Wide-Neck Basilar Tip Aneurysms [J].
Cho, Young Dae ;
Park, Sun-Won ;
Lee, Jong Young ;
Seo, Jung Hwa ;
Kang, Hyun-Seung ;
Kim, Jeong Eun ;
Han, Moon Hee .
NEUROSURGERY, 2012, 70 (06) :244-249
[9]  
Chow MM, 2004, AM J NEURORADIOL, V25, P509
[10]   PIV-measured versus CFD-predicted flow dynamics in anatomically realistic cerebral aneurysm models [J].
Ford, Matthew D. ;
Nikolov, Hristo N. ;
Milner, Jaques S. ;
Lownie, Stephen P. ;
DeMont, Edwin M. ;
Kalata, Wojciech ;
Loth, Francis ;
Holdsworth, David W. ;
Steinman, David A. .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2008, 130 (02)