A novel electrochemiluminescence resonance energy transfer system for simultaneous determination of two acute myocardial infarction markers using versatile gold nanorods as energy acceptors

被引:48
作者
Cao, Jun-Tao [1 ]
Liu, Fu-Rao [1 ]
Fu, Xiao-Long [1 ]
Ma, Jin-Xin [1 ]
Ren, Shu-Wei [2 ]
Liu, Yan-Ming [1 ]
机构
[1] Xinyang Normal Univ, Coll Chem & Chem Engn, Inst Conservat & Utilizat Agrobioresources Dabie, Xinyang 464000, Peoples R China
[2] Xinyang Cent Hosp, Xinyang 464000, Peoples R China
基金
中国国家自然科学基金;
关键词
POTENTIAL-RESOLVED ELECTROCHEMILUMINESCENCE; ELECTROGENERATED CHEMILUMINESCENCE; ARRAY; AMPLIFICATION; NANOPARTICLES; BIOSENSOR; APTASENSOR; STRATEGY; LABELS;
D O I
10.1039/c9cc00563c
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
A novel electrochemiluminescence resonance energy transfer (ECL-RET) system using versatile gold nanorods as energy acceptors was introduced into the ECL biochemical analysis. A spatial- and potential-resolved platform coupled with the ECL-RET strategy was developed for simultaneous determination of two acute myocardial infarction markers.
引用
收藏
页码:2829 / 2832
页数:4
相关论文
共 25 条
[11]   Cross-talk-free multiplexed immunoassay using a disposable electrochemiluminescent immunosensor array coupled with a non-array detector [J].
Li, Cuifang ;
Fu, Zhifeng ;
Li, Zongyun ;
Wang, Zhenxing ;
Wei, Wei .
BIOSENSORS & BIOELECTRONICS, 2011, 27 (01) :141-147
[12]   Recent advances in new luminescent nanomaterials for electrochemiluminescence sensors [J].
Li, Jing ;
Guo, Shaojun ;
Wang, Erkang .
RSC ADVANCES, 2012, 2 (09) :3579-3586
[13]   Recent Advances in Electrochemiluminescence Analysis [J].
Li, Lingling ;
Chen, Ying ;
Zhu, Jun-Jie .
ANALYTICAL CHEMISTRY, 2017, 89 (01) :358-371
[14]   Coupled Fluorometer-Potentiostat System and Metal-Free Monochromatic Luminophores for High-Resolution Wavelength-Resolved Electrochemiluminescent Multiplex Bioassay [J].
Lv, Yanqin ;
Zhou, Zhixin ;
Shen, Yanfei ;
Zhou, Qing ;
Ji, Jingjing ;
Liu, Songqin ;
Zhang, Yuanjian .
ACS SENSORS, 2018, 3 (07) :1362-1367
[15]   Signal-enhancer molecules encapsulated liposome as a valuable sensing and amplification platform combining the aptasensor for ultrasensitive ECL immunoassay [J].
Mao, Li ;
Yuan, Ruo ;
Chai, Yaqin ;
Zhuo, Ying ;
Xiang, Yun .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (10) :4204-4208
[16]   Electrogenerated chemiluminescence and its biorelated applications [J].
Miao, Wujian .
CHEMICAL REVIEWS, 2008, 108 (07) :2506-2553
[17]   A ratiometric electrochemiluminescence detection for cancer cells using g-C3N4 nanosheets and Ag-PAMAM-luminol nanocomposites [J].
Wang, Yin-Zhu ;
Hao, Nan ;
Feng, Qiu-Mei ;
Shi, Hai-Wei ;
Xu, Jing-Juan ;
Chen, Hong-Yuan .
BIOSENSORS & BIOELECTRONICS, 2016, 77 :76-82
[18]   Spatial-resolved dual-signal-output electrochemiluminescent ratiometric strategy for accurate and sensitive immunoassay [J].
Wang, Yu-Ling ;
Liu, Fu-Rao ;
Cao, Jun-Tao ;
Ren, Shu-Wei ;
Liu, Yan-Ming .
BIOSENSORS & BIOELECTRONICS, 2018, 102 :525-530
[19]   Sensitive electrochemiluminescence resonance energy transfer (ECL-RET) between Ru(bpy)32+ and Au nanorod for hydrogen peroxide detection [J].
Wu, Meisheng ;
Chen, Zhiqin ;
Xu, Hengyu ;
Zhang, Aiping .
SCIENCE CHINA-CHEMISTRY, 2017, 60 (03) :410-414
[20]   Electrogenerated chemiluminescence biosensor array for the detection of multiple AMI biomarkers [J].
Yang, Xiaolin ;
Zhao, Ying ;
Sun, Lijuan ;
Qi, Honglan ;
Gao, Qiang ;
Zhang, Chengxiao .
SENSORS AND ACTUATORS B-CHEMICAL, 2018, 257 :60-67