A mechanical comparison between conventional and modified angular plates for proximal humeral fractures

被引:7
作者
Carrera, Eduardo F. [1 ]
Nicolao, Fabio A. [1 ]
Archetti Netto, Nicola [1 ]
Carvalho, Renato L. [1 ]
dos Reis, Fernando B. [1 ]
Giordani, Enrico Jose [2 ]
机构
[1] Univ Fed Sao Paulo, Dept Orthopaed & Trauma, Sao Paulo, Brazil
[2] Univ Estadual Campinas, Coll Mech Engn, Dept Mat Engn, Campinas, SP, Brazil
关键词
D O I
10.1016/j.jse.2008.02.003
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The objective of this study is to present a modified angular blade plate for fixing 2-part and even 3-part fractures of the proximal humerus, as well as the results of the comparative mechanical test between the conventional angular blade plate and this new modified plate. The plates were tested in flexion and rotational trials in a wooden model that simulated a 2-part humeral fracture of the proximal extremity. The results (mean +/- SD) of bending strength and stiffness obtained after testing showed findings of 601 +/- 349 N and 0.5 +/- 0.2 N/mm, respectively, for the conventional plate and 4005 +/- 164 N and 3.9 +/- 0.7 N/mm, respectively, for the modified plate. The torsional stiffness test showed findings of 1.26 +/- 0.09 KN.mm degrees for the conventional plate and 1.74 +/- 0.21 KN.mm degrees for the modified plate. The test of torsional moment showed findings of 57.0 +/- 7.6 KN.mm for the conventional plate and 115.2 +/- 9.3 KN.mm for the modified plate. The test of angular displacement of the torsional moment showed findings of 50.8 degrees +/- 7.2 degrees for the conventional plate and 70.2 degrees +/- 2.6 degrees for the modified plate. The results of the mechanical trials of flexion and rotation were superior for the modified angular blade plate compared with the conventional angular blade plate.
引用
收藏
页码:631 / 636
页数:6
相关论文
共 10 条
[1]  
*AM SOC TEST MAT, 2000, F384 ASTM
[2]   Fixed-angle plate fixation in simulated fractures of the proximal humerus: A biomechanical study of a new device [J].
Chudik, SC ;
Weinhold, P ;
Dahners, LE .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2003, 12 (06) :578-588
[3]   Two-part surgical neck fractures of the humerus: Mechanical analysis of the fixation with four Shanz-type threaded pins in four different assemblies [J].
Durigan, A ;
Barbieri, CH ;
Mazzer, N ;
Shimano, AC .
JOURNAL OF SHOULDER AND ELBOW SURGERY, 2005, 14 (01) :96-102
[4]   A new locking plate for unstable fractures of the proximal humerus [J].
Fankhauser, F ;
Boldin, C ;
Schippinger, G ;
Haunschmid, C ;
Szyszkowitz, R .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2005, (430) :176-181
[5]   OPEN REDUCTION AND INTERNAL-FIXATION OF 2-PART DISPLACED FRACTURES OF THE GREATER TUBEROSITY OF THE PROXIMAL PART OF THE HUMERUS [J].
FLATOW, EL ;
CUOMO, F ;
MADAY, MG ;
MILLER, SR ;
MCILVEEN, SJ ;
BIGLIANI, LU .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1991, 73A (08) :1213-1218
[6]   Interventions for treating proximal humeral fractures in adults [J].
Handoll, Helen H. G. ;
Ollivere, Benjamin J. ;
Rollins, Katie E. .
COCHRANE DATABASE OF SYSTEMATIC REVIEWS, 2012, (12)
[7]   Locked plate fixation and intramedullary nailing for proximal humerus fractures: A biomechanical evaluation [J].
Hessmann, MH ;
Hansen, WSM ;
Krummenauer, F ;
Pol, TF ;
Rommens, M .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2005, 58 (06) :1194-1201
[8]   Rigid internal fixation of fractures of the proximal humerus in older patients [J].
Hintermann, B ;
Trouillier, HH ;
Schäfer, D .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2000, 82B (08) :1107-1112
[9]   Surgical neck fractures of the proximal humerus: A laboratory evaluation of ten fixation techniques [J].
Koval, KJ ;
Blair, B ;
Takei, R ;
Kummer, FJ ;
Zuckerman, JD .
JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1996, 40 (05) :778-783