Enhancing IgG purification from serum albumin containing feedstock with hydrophobic charge-induction chromatography

被引:47
|
作者
Tong, Hong-Fei [1 ]
Lin, Dong-Qiang [1 ]
Yuan, Xiao-Ming [1 ]
Yao, Shan-Jing [1 ]
机构
[1] Zhejiang Univ, Dept Chem & Biol Engn, State Key Lab Chem Engn, Hangzhou 310027, Peoples R China
基金
中国国家自然科学基金;
关键词
Hydrophobic charge-induction chromatography; Immunoglobulin G; Serum albumin; Purification; pH control; Salt addition; MIXED-MODE CHROMATOGRAPHY; PROTEIN ADSORPTION; ANTIBODY; LIGAND; ADSORBENTS; SEPARATION; CAPTURE; BINDING; PH;
D O I
10.1016/j.chroma.2012.04.073
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrophobic charge-induction chromatography (HCIC) with 4-mercaptoethyl-pyridine (MEP) as the ligand is a novel technology for antibody purification, however, the separation selectivity still needs to be improved for the applications, especially for the impurity of serum albumin. In this study, with bovine serum immunoglobulin G (IgG) as the model, the purification of IgG from the serum albumin containing feedstock was developed with the commercial HCIC resin MEP HyperCel, focusing on the optimization of operation pH and salt addition. The adsorption isotherms of IgG and bovine serum albumin (BSA) were investigated at different pHs, and the binding and elution behaviors of two proteins in the column were also studied at varying pHs. In addition, the protein-ligand interactions were investigated with some additives in the buffer. It was found that the conditions of pH 6 with 0.1 M NaCl or pH 8 could be used to effectively remove BSA from the MEP resin without the influence on IgG adsorption. Two modes with control of loading or washing buffer were tested to enhance the purification of IgG from BSA containing feedstock, and the purity of IgG was improved to about 95% compared with 62.9% for the control. The results demonstrated that the control of loading pH or the addition of NaCl in the buffer might be an effective method to improve the purification of antibody with the HCIC process. (C) 2012 Elsevier B.V. All rights reserved.
引用
收藏
页码:116 / 122
页数:7
相关论文
共 35 条
  • [21] Molecular mechanism of hydrophobic charge-induction chromatography: Interactions between the immobilized 4-mercaptoethyl-pyridine ligand and IgG
    Lin, Dong-Qiang
    Tong, Hong-Fei
    Wang, Hong-Yin
    Shao, Shuang
    Yao, Shan-Jing
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1260 : 143 - 153
  • [22] Dual-recognition membrane Adsorbers combining hydrophobic charge-induction chromatography with surface imprinting via multicomponent reaction
    Guo, Miaoyuan
    Ye, Jianlong
    Zheng, Chunyang
    Meng, Jianqiang
    JOURNAL OF CHROMATOGRAPHY A, 2022, 1668
  • [23] A study of the small-molecule system used to investigate the effect of arginine on antibody elution in hydrophobic charge-induction chromatography
    Hirano, Atsushi
    Maruyama, Takuya
    Shiraki, Kentaro
    Arakawa, Tsutomu
    Kameda, Tomoshi
    PROTEIN EXPRESSION AND PURIFICATION, 2017, 129 : 44 - 52
  • [24] Experimental and in silico studies on three hydrophobic charge-induction adsorbents for porcine immunoglobulin purification
    Qilei Zhang
    Tiantian Zhuang
    Hongfei Tong
    Hongyin Wang
    Dongqiang Lin
    Shanjing Yao
    Chinese Journal of Chemical Engineering, 2016, 24 (01) : 151 - 157
  • [25] Penicillin acylase purification with the aid of hydrophobic charge induction chromatography
    Coulon, D
    Cabanne, C
    Fitton, V
    Noubhani, AM
    Saint-Christophe, E
    Santarelli, X
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2004, 808 (01): : 111 - 115
  • [26] Purification of Immunoglobulin of Egg Yolk with Hydrophobic Charge Induction Chromatography: Comparison of Operation Modes with Packed Bed and Expanded Bed
    Xia, Hai-Feng
    Lin, Dong-Qiang
    Chen, Zhen-Ming
    Yao, Shan-Jing
    SEPARATION SCIENCE AND TECHNOLOGY, 2012, 47 (16) : 2366 - 2372
  • [27] Surface Modification of Cellulose Membranes To Prepare a High-Capacity Membrane Adsorber for Monoclonal Antibody Purification via Hydrophobic Charge-Induction Chromatography
    Ma, Na
    Yao, Dongxue
    Yang, Hui
    Yin, Jian
    Wang, Hua
    Zhang, Yufeng
    Meng, Jianqiang
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2018, 57 (39) : 13235 - 13246
  • [28] Comparison of hydrophobic charge induction chromatography with affinity chromatography on protein A for harvest and purification of antibodies
    Schwartz, W
    Judd, D
    Wysocki, M
    Guerrier, L
    Birck-Wilson, E
    Boschetti, E
    JOURNAL OF CHROMATOGRAPHY A, 2001, 908 (1-2) : 251 - 263
  • [29] Mesoscopic coarse-grained simulations of hydrophobic charge induction chromatography (HCIC) for protein purification
    Yu, Gaobo
    Liu, Jie
    Zhou, Jian
    AICHE JOURNAL, 2015, 61 (06) : 2035 - 2047
  • [30] Transforming waste into valuables: Preparation and evaluation of dual-ligand hydrophobic charge-induction chromatography using two poor performing ligands
    Shi, Wei
    Zhang, Tian-Yi
    Fang, Chao-Ying
    Zhang, Si-Qi
    Li, Kai -Bin
    Zhang, Xiao-Bin
    Han, De -Man
    JOURNAL OF CHROMATOGRAPHY A, 2024, 1726