Relationship between macular ganglion cell complex thickness and macular outer retinal thickness: a spectral-domain optical coherence tomography study

被引:17
作者
Kita, Yoshiyuki [1 ]
Kita, Ritsuko [1 ]
Takeyama, Asuka [1 ]
Anraku, Ayako [1 ]
Tomita, Goji [1 ]
Goldberg, Ivan [2 ,3 ,4 ]
机构
[1] Toho Univ, Ohashi Med Ctr, Dept Ophthalmol, Tokyo 1538515, Japan
[2] Univ Sydney, Eye Associates, Sydney, NSW 2006, Australia
[3] Univ Sydney, Glaucoma Unit, Sydney Eye Hosp, Sydney, NSW 2006, Australia
[4] Univ Sydney, Discipline Ophthalmol, Sydney, NSW 2006, Australia
关键词
ganglion cell complex; glaucoma; outer retinal thickness; ratio; spectral-domain optical coherence tomography; NERVE-FIBER LAYER; VISUAL-FIELD SENSITIVITY; GLAUCOMATOUS DAMAGE; DETECT GLAUCOMA; MYOPIC EYES; OCT; VOLUME; DIAGNOSIS;
D O I
10.1111/ceo.12089
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BackgroundTo assess the relationship between macular ganglion cell complex and macular outer retinal thicknesses. DesignCase-control study. ParticipantsForty-two normal eyes and 91 eyes with primary open-angle glaucoma were studied. MethodsSpectral-domain optical coherence tomography (RTVue-100) was used to measure the macular ganglion cell complex and macular outer retinal thickness. Ganglion cell complex to outer retinal thickness ratio was also calculated. Main Outcome MeasuresThe relationships between the ganglion cell complex and outer retinal thicknesses and between the ganglion cell complex to outer retinal thickness ratio and outer retinal thickness were evaluated. ResultsThere was a positive correlation between ganglion cell complex and outer retinal thicknesses in the normal group and the glaucoma group (r=0.53, P<0.001 and r=0.42, P<0.001, respectively). In that respect, there was no correlation between ganglion cell complex to outer retinal thickness ratio and outer retinal thickness in the both groups (r=-0.07, P=0.657, and r=0.04, P=0.677, respectively). The ganglion cell complex to outer retinal thickness ratio was 55.65% in the normal group, 45.07% in the glaucoma group. This difference was statistically significant. ConclusionsThe ganglion cell complex thickness may be affected by outer retinal thickness, and there is individual variation in the outer retinal thickness. Therefore, when determining the ganglion cell complex, it seems necessary to consider the outer retinal thickness as well. We propose the ratio as a suitable parameter to account for individual variations in outer retinal thickness.
引用
收藏
页码:674 / 682
页数:9
相关论文
共 35 条
[1]   Retinal Nerve Fiber Layer Thickness in Normals Measured by Spectral Domain OCT [J].
Bendschneider, Delia ;
Tornow, Ralf P. ;
Horn, Folkert K. ;
Laemmer, Robert ;
Roessler, Christopher W. ;
Juenemann, Anselm G. ;
Kruse, Friedrich E. ;
Mardin, Christian Y. .
JOURNAL OF GLAUCOMA, 2010, 19 (07) :475-482
[2]   Structure-function relationships using confocal scanning laser ophthalmoscopy, optical coherence tomography, and scanning laser polarimetry [J].
Bowd, Christopher ;
Zangwill, Linda M. ;
Medeiros, Felipe A. ;
Tavares, Ivan M. ;
Hoffmann, Esther M. ;
Bourne, Rupert R. ;
Sample, Pamela A. ;
Weinreb, Robert N. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2006, 47 (07) :2889-2895
[3]   Relationship between Visual Field Sensitivity and Macular Ganglion Cell Complex Thickness as Measured by Spectral-Domain Optical Coherence Tomography [J].
Cho, Jung Woo ;
Sung, Kyung Rim ;
Lee, Suhwan ;
Yun, Sung-Cheol ;
Kang, Sung Yong ;
Choi, Jaewan ;
Na, Jung Hwa ;
Lee, Youngrok ;
Kook, Michael S. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) :6401-6407
[4]   Diagnostic accuracy of nerve fibre layer, macular thickness and optic disc measurements made with the RTVue-100 optical coherence tomograph to detect glaucoma [J].
Garas, A. ;
Vargha, P. ;
Hollo, G. .
EYE, 2011, 25 (01) :57-65
[5]   Variation in Optic Nerve and Macular Structure with Age and Race with Spectral-Domain Optical Coherence Tomography [J].
Girkin, Christopher A. ;
McGwin, Gerald, Jr. ;
Sinai, Micheal J. ;
Sekhar, G. Chandra ;
Fingeret, Murrey ;
Wollstein, Gadi ;
Varma, Rohit ;
Greenfield, David ;
Liebmann, Jeffery ;
Araie, Makoto ;
Tomita, Goji ;
Maeda, Naoyuki ;
Garway-Heath, David F. .
OPHTHALMOLOGY, 2011, 118 (12) :2403-2408
[6]   Diffuse Glaucomatous Structural and Functional Damage in the Hemifield Without Significant Pattern Loss [J].
Grewal, Dilraj S. ;
Sehi, Mitra ;
Greenfield, David S. .
ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (11) :1442-1448
[7]   Optical coherence tomography measurement of macular and nerve fiber layer thickness in normal and glaucomatous human eyes [J].
Guedes, V ;
Schuman, JS ;
Hertzmark, E ;
Wollstein, G ;
Correnti, A ;
Mancini, R ;
Lederer, D ;
Voskanian, S ;
Velazquez, L ;
Pakter, HM ;
Pedut-Kloizman, T ;
Fujimoto, JG ;
Mattox, C .
OPHTHALMOLOGY, 2003, 110 (01) :177-189
[8]   Evaluation of the glaucomatous damage on retinal nerve fiber layer thickness measured by optical coherence tomography [J].
Kanamori, A ;
Nakamura, M ;
Escano, MFT ;
Seya, R ;
Maeda, H ;
Negi, A .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 135 (04) :513-520
[9]   Peripapillary retinal nerve fibre layer thickness profile in subjects with myopia measured using the Stratus optical coherence tomography [J].
Kim, M. J. ;
Lee, E. J. ;
Kim, T-W .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2010, 94 (01) :115-120
[10]   Comparing the ganglion cell complex and retinal nerve fibre layer measurements by Fourier domain OCT to detect glaucoma in high myopia [J].
Kim, Na Rae ;
Lee, Eun Suk ;
Seong, Gong Je ;
Kang, Sung Yong ;
Kim, Ji Hyun ;
Hong, Samin ;
Kim, Chan Yun .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (08) :1115-1121