Nonlinear analysis of the ECG during atrial fibrillation inn patients for low energy internal cardioversion

被引:1
作者
Diaz, J. [1 ]
Gonzalez, C. [1 ]
Escalona, O. [2 ]
Glover, B. M. [3 ]
Manoharan, G. [3 ]
机构
[1] Univ Simon Bolivar, Coro, Venezuela
[2] Univ Belfast, Belfast, Antrim, North Ireland
[3] Royal Victoria Hosp, Belfast, Antrim, North Ireland
来源
2008 30TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-8 | 2008年
关键词
D O I
10.1109/IEMBS.2008.4649483
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The goal of this study was to investigate the usefulness of nonlinear analysis in determining the success of low energy internal cardioversion (IC) in patients with atrial fibrillation (AF). Nonlinear analysis has previously been used for characterizing AF patterns, and spontaneous termination in its paroxysmal form. However, the relationship between the probability to restore sinus rhythm by IC and quantitative nonlinear analysis based electrocardiographic (ECG) markers has not been explored before. Thirty nine patients with AF, for elective DC cardioversion at the Royal Victoria Hospital in Belfast, were included in this study. One catheter was positioned in the right atrial appendage and another in the coronary sinus, to deliver a biphasic shock waveform. A voltage step-up protocol (50-300 V) was used for patient cardioversion. Residual atrial fibrillatory signal (RAFS) was derived from 60 seconds of surface ECG from defibrillator pads, prior to shock delivery, by bandpass filtering and ventricular activity (QRST) cancellation. QRST complexes were cancelled using a recursive least squared (RLS) adaptive filter. The maximal Lyapunov exponent (lambda), correlation dimension (course grained estimation, CDcg) and approximate entropy (ApEn) were extracted from the RAFS. These variables were calculated from 10 s of the RAFS before shock delivery. 26 patients were successfully cardioverted, employing a maximum energy of 11.84 joules. A lower lambda (0.037 +/- 0.006 vs. 0.044 +/- 0.008, P=0.01) and CDcg (5.552 +/- 2.075 vs. 6.592 +/- 1.130, P=0.049) were found in successfully cardioverted patients than in those non successful ones, with an energy <= 3 joules. Also, there was a significant positive correlation between the minimal defibrillation energy and lambda (p=0.483, P=0.013) in cardioverted patients. In conclusion, complexity analysis of the RAFS is useful for assessing the prospective efficacy of internal low energy cardioversion of patients with atria! fibrillation.
引用
收藏
页码:1619 / +
页数:2
相关论文
共 18 条
[1]  
Akay M., 2001, NONLINEAR BIOMEDICAL, VII
[2]   Atrial fibrillatory frequency predicts atrial defibrillation threshold and early arrhythmia recurrence in patients undergoing internal cardioversion of persistent atrial fibrillation [J].
Bollmann, A ;
Mende, M ;
Neugebauer, A ;
Pfeiffer, D .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (08) :1179-1184
[3]   Frequency analysis of human atrial fibrillation using the surface electrocardiogram and its response to ibutilide [J].
Bollmann, A ;
Kanuru, NK ;
McTeague, KK ;
Walter, PF ;
DeLurgio, DB ;
Langberg, JJ .
AMERICAN JOURNAL OF CARDIOLOGY, 1998, 81 (12) :1439-1445
[4]   DYNAMIC ELECTROPHYSIOLOGICAL BEHAVIOR OF HUMAN ATRIA DURING PAROXYSMAL ATRIAL-FIBRILLATION [J].
CAPUCCI, A ;
BIFFI, M ;
BORIANI, G ;
RAVELLI, F ;
NOLLO, G ;
SABBATANI, P ;
ORSI, C ;
MAGNANI, B .
CIRCULATION, 1995, 92 (05) :1193-1202
[5]  
ESCALONA OJ, 2004, DEV CIRC SYST 2004 P
[6]   ACC/AHA/ESC 2006 guidelines for the management of patients with atrial fibrillation:: full text [J].
Fuster, Valentin ;
Ryden, Lars E. ;
Cannom, David S. ;
Crijns, Harry J. ;
Curtis, Anne B. ;
Ellenbogen, Kenneth A. ;
Halperin, Jonathan L. ;
Le Heuzey, Jean-Yves ;
Kay, G. Neal ;
Lowe, James E. ;
Olsson, S. Bertil ;
Prystowsky, Eric N. ;
Tamargo, Juan Luis ;
Wann, Samuel .
EUROPACE, 2006, 8 (09) :651-745
[7]   Prevalence, incidence and lifetime risk of atrial fibrillation: the Rotterdam study [J].
Heeringa, J ;
van der Kuip, DAM ;
Hofman, A ;
Kors, JA ;
van Herpen, G ;
Stricker, BHC ;
Stijnen, T ;
Lip, GYH ;
Witteman, JCM .
EUROPEAN HEART JOURNAL, 2006, 27 (08) :949-953
[8]   Practical implementation of nonlinear time series methods: The TISEAN package [J].
Hegger, R ;
Kantz, H ;
Schreiber, T .
CHAOS, 1999, 9 (02) :413-435
[9]   NONLINEAR-ANALYSIS OF EPICARDIAL ATRIAL ELECTROGRAMS OF ELECTRICALLY-INDUCED ATRIAL-FIBRILLATION IN MAN [J].
HOEKSTRA, BPT ;
DIKS, CGH ;
ALLESSIE, MA ;
DEGOEDE, J .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 1995, 6 (06) :419-440
[10]   Non-invasive assessment of the atrial cycle length during atrial fibrillation in man:: introducing, validating and illustrating a new ECG method [J].
Holm, M ;
Pehrson, S ;
Ingemansson, M ;
Sörnmo, L ;
Johansson, R ;
Sandhall, L ;
Sunemark, M ;
Smideberg, B ;
Olsson, SB .
CARDIOVASCULAR RESEARCH, 1998, 38 (01) :69-81