Changes in upper limb extracellular water content during hemodialysis measured by multi-frequency bioimpedance

被引:1
作者
Kumar, Sanjeev [1 ]
Khosravi, Maryam [1 ]
Massart, Annick [1 ]
Potluri, Madhu [1 ]
Davenport, Andrew [1 ]
机构
[1] UCL, UCL Ctr Nephrol, Royal Free Hosp, Sch Med, London NW3 2PF, England
关键词
Dialysis; Bioimpedance; Vascular access; Arterio-venous fistula; Catheter; DIALYSIS PATIENTS; VOLUME EXPANSION; FLUID; HYPOTENSION; ACCESS; MODEL;
D O I
10.5301/ijao.5000190
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Introduction: Hemodialysis patients are at risk of chronic volume overload, with consequent increased cardiovascular morbidity and mortality. Multifrequency bioimpedance allows assessment of body fluid volumes. Devices vary from two paired electrodes which measure bioimpedance down one side of the body to four paired electrodes which measure both sides of the body. As arteriovenous fistulae may cause arm swelling, we investigated whether the presence of a fistula affected bioimpedance limb measurements. Methods: We audited the change in extracellular water (ECW) and total body water (TBW) in the arms following hemodialysis in 414 adult patients attending for routine mid-week hemodialysis session by multifrequency bioimpedance using a four-paired electrode bioimpedance device (InBody 720; Biospace, Seoul, South Korea). Results: Patients with right-sided brachial fistulae had a greater percentage ECW/TBW in the fistula arm both prior to and post dialysis compared to those dialyzing with catheters (pre 39.6 +/- 3.5 vs. 38.4.3 +/- 1.6 and post 38.5 +/- 1.3 vs. 37.8 +/- 1.1, p<0.01), but there was no difference in the ECW/TBW in the non-fistula arm, pre dialysis between those dialyzing with fistulae compared to catheters, but the ECW/TBW was greater post dialysis with both brachial (38.4 +/- 1.1) and radial fistulae (38.1 +/- 1.3) compared to those with catheters (37.7 +/- 0.9, p<0.05 respectively). Conclusions: Although absolute and also relative extracellular fluid volumes are increased in the fistula arm of hemodialysis patients, particularly right-sided and with brachial fistulae, the amount of fluid is unlikely to be of clinical significance when making bioimpedance measurements in the non-fistula side of the body to determine volume status.
引用
收藏
页码:203 / 207
页数:5
相关论文
共 18 条
[1]  
[Anonymous], NAT SERV FRAM REN 1
[2]   The effect of vascular access modality on changes in fluid content in the arms as determined by multifrequency bioimpedance [J].
Booth, John ;
Pinney, Jennifer ;
Davenport, Andrew .
NEPHROLOGY DIALYSIS TRANSPLANTATION, 2011, 26 (01) :227-231
[3]   Do Changes in Relative Blood Volume Monitoring Correlate to Hemodialysis-Associated Hypotension? [J].
Booth, John ;
Pinney, Jennifer ;
Davenport, Andrew .
NEPHRON CLINICAL PRACTICE, 2011, 117 (03) :C179-C183
[4]   A whole-body model to distinguish excess fluid from the hydration of major body tissues [J].
Chamney, Paul W. ;
Wabel, Peter ;
Moissl, Ulrich M. ;
Mueller, Manfred J. ;
Bosy-Westphal, Anja ;
Korth, Oliver ;
Fuller, Nigel J. .
AMERICAN JOURNAL OF CLINICAL NUTRITION, 2007, 85 (01) :80-89
[5]  
Davenport Andrew, 2006, Hemodial Int, V10, P162
[6]   How best to improve survival in hemodialysis patients: solute clearance or volume control? [J].
Davenport, Andrew .
KIDNEY INTERNATIONAL, 2011, 80 (10) :1018-1020
[7]  
Davenport A, 2010, INT J ARTIF ORGANS, V33, P700
[8]   Comparison of fluid status in patients treated by different modalities of peritoneal dialysis using multi-frequency bioimpedance [J].
Davenport, Andrew ;
Willicombe, Michelle .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2009, 32 (11) :779-786
[9]   Can Advances in Hemodialysis Machine Technology Prevent Intradialytic Hypotension? [J].
Davenport, Andrew .
SEMINARS IN DIALYSIS, 2009, 22 (03) :231-236
[10]   Extracellular volume expansion in peritoneal dialysis patients [J].
Fan, Stanley ;
Sayed, Rabya H. ;
Davenport, Andrew .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2012, 35 (05) :338-345