Electrochemical strategies for gallic acid detection: Potential for application in clinical, food or environmental analyses

被引:65
作者
Badea, Mihaela [1 ]
di Modugno, Federico [2 ]
Floroian, Laura [3 ]
Tit, Delia Mirela [4 ]
Restani, Patrizia [2 ]
Bungau, Simona [4 ]
Iovan, Ciprian [5 ]
Badea, Gabriela Elena [6 ]
Aleya, Lotfi [7 ]
机构
[1] Transilvania Univ Brasov, Fac Med, Dept Fundamental Prophylact & Clin Disciplines, Brasov 00039, Romania
[2] Univ Milan, Dept Pharmacol & Biomol Sci, Fac Pharmacol Sci, I-20133 Milan, Italy
[3] Transylvania Univ Brasov, Dept Automat & Informat Technol, Fac Elect Engn & Comp Sci, Brasov 500039, Romania
[4] Univ Oradea, Dept Pharm, Fac Med & Pharm, Oradea 410028, Romania
[5] Univ Oradea, Dept Preclin Disciplines, Fac Med & Pharm, Oradea 410028, Romania
[6] Univ Oradea, Dept Chem, Fac Sci, Oradea 410087, Romania
[7] Univ Franche Comte, Lab Chronoenvironm, Besancon, France
关键词
Electrochemical detection; Gallic acid; Differential pulse voltammetry; Screen-printed carbon electrode; Redox microsensor; DIFFERENTIAL-PULSE VOLTAMMETRY; ANTIOXIDANT CAPACITY; CYCLIC VOLTAMMETRY; IMPEDANCE SPECTROSCOPY; CARBON ELECTRODE; URIC-ACID; SENSOR; NANOPARTICLES; POLYPHENOLS; REDUCTION;
D O I
10.1016/j.scitotenv.2019.03.404
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Polyphenols are important to human health thus making it interesting and necessary to identify and assess methods for their detection. Gallic acid (GA) is a well-known antioxidant compound, found in tea leaves, various fruits, fruit seeds and in fruit-derived foods and beverages. In this study, to electrochemically detect this compound and assess the potential for GA detection, different analytical conditions at pH values of 5.8, 7 and 8 were tried. Two types of device were used for GA detection: (1) Lazar ORP-146C reduction-oxidation microsensors, coupled with a Jenco device, for estimation of antioxidant capacities of different electroactive media, and (2) screen-printed carbon sensors coupled with a mobile PalmSens device using differential pulse voltammetry (qualitative and quantitative GA determination). These proposed methods were validated by analysing some real samples: wine, green tea, apple juice and serum fortified with GA. Detection was evaluated in terms of specific calibration curves, with low limit of detection (LOD) and limit of quantification (LOQ), low response time, and high sensitivities. The analytical characteristics obtained recommend these methods to be tested on more other types of real samples. Our proposed methods, used in the established conditions of pH, may have further application in other clinical, food or environmental samples analyses in which the results of total antioxidants contents are usually expressed in GA equivalents. (C) 2019 Elsevier B.V. All rights reserved.
引用
收藏
页码:129 / 140
页数:12
相关论文
共 99 条
  • [1] Alleviation of Drugs and Chemicals Toxicity: Biomedical Value of Antioxidants
    Abdel-Daim, Mohamed M.
    Abo-EL-Sooud, Khaled
    Aleya, Lotfi
    Bungau, Simona G.
    Najda, Agnieszka
    Saluja, Rohit
    [J]. OXIDATIVE MEDICINE AND CELLULAR LONGEVITY, 2018, 2018
  • [2] Adsorptive stripping voltammetric determination of gallic acid using an electrochemical sensor based on polyepinephrine/glassy carbon electrode and its determination in black tea sample
    Abdel-Hamid, Refat
    Newair, Emad F.
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2013, 704 : 32 - 37
  • [3] Electrochemical behaviour and antioxidant capacity of anthocyanins from Chilean red wine, grape and raspberry
    Aguirre, Maria J.
    Chen, Yo Y.
    Isaacs, Mauricio
    Matsuhiro, Betty
    Mendoza, Leonora
    Torres, Simonet
    [J]. FOOD CHEMISTRY, 2010, 121 (01) : 44 - 48
  • [4] Gallic Acid: Review of the Methods of Determination and Quantification
    Alencar Fernandes, Felipe Hugo
    Nunes Salgado, Herida Regina
    [J]. CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 2016, 46 (03) : 257 - 265
  • [5] [Anonymous], 2016, SENSORS BASEL, DOI DOI 10.3390/S16111931
  • [6] Carbon Paste Electrodes Made from Different Carbonaceous Materials: Application in the Study of Antioxidants
    Apetrei, Constantin
    Mirela Apetrei, Irina
    Antonio De Saja, Jose
    Luz Rodriguez-Mendez, Maria
    [J]. SENSORS, 2011, 11 (02) : 1328 - 1344
  • [7] Comparison of the Simple Cyclic Voltammetry (CV) and DPPH Assays for the Determination of Antioxidant Capacity of Active Principles
    Arteaga, Jesus F.
    Ruiz-Montoya, Mercedes
    Palma, Alberto
    Alonso-Garrido, Gema
    Pintado, Sara
    Rodriguez-Mellado, Jose M.
    [J]. MOLECULES, 2012, 17 (05): : 5126 - 5138
  • [8] Antioxidant activity of gallic acid and methyl gallate in triacylglycerols of Kilka fish oil and its oil-in-water emulsion
    Asnaashari, Maryarn
    Farhoosh, Reza
    Sharif, Ali
    [J]. FOOD CHEMISTRY, 2014, 159 : 439 - 444
  • [9] Badea GE, 2006, REV ROUM CHIM, V51, P127
  • [10] Badea M, 2018, FARMACIA, V66, P83