Incomplete expansion of Palmaz-Schatz stents despite high-pressure implantation technique:: Impact on target lesion revascularization

被引:4
作者
Blessing, E [1 ]
Hausmann, D [1 ]
Sturm, M [1 ]
Wolpers, HG [1 ]
Amende, I [1 ]
Mügge, A [1 ]
机构
[1] Hannover Med Sch, Dept Internal Med, Div Cardiol, Hannover, Germany
关键词
high-pressure implantation; stent expansion; intravascular ultrasound; restenosis;
D O I
10.1159/000006888
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Improved expansion of stents using high-pressure implantation technique with subsequent antiplatelet therapy has improved patient outcome regarding the incidence of subacute stent thrombosis, bleeding complications and restenosis. Whether high-pressure implantation per se guarantees adequate stent expansion remains unclear. The aim of the study was to determine (1)stent expansion after high-pressure implantation technique and (2)whether stent expansion influences rate of target lesion revascularization within 6 months of follow-up. One hundred Palmaz-Schatz stents were implanted in 98 lesions (91 native vessels, 7 graft vessels) of 94 patients using high-pressure implantation technique (balloon pressure 12-20 atm). Stent expansion was investigated using intravascular ultrasound imaging (IVUS). Clinical follow-up of the patients was performed for 6 months. After implantation, stent/mean reference ratio was 0.81 +/- 0.16. Noncompliant balloons used for implantation were chosen by angiographic criteria. Mean balloon/reference ratio was 1.08 +/- 0.22; therefore balloons were not undersized. Additional balloon dilataion using higher pressures and/or larger balloons based on IVUS criteria and subsequent IVUS measurements was performed in 52 patients (55%); in these patients, stent expansion improved from 79 +/- 16 to 91 +/- 15% (mean +/- SD) of average reference areas (p < 0.002), Within the 6 months' clinical follow-up, target lesion revascularization was performed in 19 patients (20%). The only prognostic factors for the development of instent restenosis requiring target lesion revascularization were the vessel size (p < 0.05) and the extent of plaque distal to the stents (p < 0.05). Implantation of Palmaz-Schatz stents using high-pressure technique does not guarantee adequate stent expansion, Additional dilatation with higher pressures and/or larger balloons improves stent expansion, The size of the stented vessel and the extent of plaque at the distal stent end (residual outflow stenosis) but not the degree of stent expansion were predictors for target lesion revascularization with in 6 months' follow-up.
引用
收藏
页码:102 / 108
页数:7
相关论文
共 30 条
[1]  
Abizaid A, 1998, CIRCULATION, V98, P229
[2]   Comparison of immediate and intermediate-term results of intravascular ultrasound versus angiography-guided Palmaz-Schatz stent implantation in matched lesions [J].
Albiero, R ;
Rau, T ;
Schluter, M ;
DiMario, C ;
Reimers, B ;
Mathey, DG ;
Tobis, JM ;
Schofer, J ;
Colombo, A .
CIRCULATION, 1997, 96 (09) :2997-3005
[3]   Arterial perforation during optimization of coronary stents using high-pressure balloon inflations [J].
Alfonso, F ;
Goicolea, J ;
Hernandez, R ;
FernandezOrtiz, A ;
Segovia, J ;
Banuelos, C ;
Aragoncillo, P ;
Phillips, P ;
Macaya, C .
AMERICAN JOURNAL OF CARDIOLOGY, 1996, 78 (10) :1169-+
[4]  
BERMEJO J, 1996, CIRCULATION S1, V94, P199
[5]  
BLASINI R, 1996, Z KARDIOL S2, V85, P476
[6]   Intravascular ultrasound and stent implantation:: Intraobserver and interobserver variability [J].
Blessing, E ;
Hausmann, D ;
Sturm, M ;
Wolpers, HG ;
Amende, I ;
Mügge, A .
AMERICAN HEART JOURNAL, 1999, 137 (02) :368-371
[7]  
BOTAS J, 1996, EUR HEART J, V17, P1020
[8]   INTRACORONARY STENTING WITHOUT ANTICOAGULATION ACCOMPLISHED WITH INTRAVASCULAR ULTRASOUND GUIDANCE [J].
COLOMBO, A ;
HALL, P ;
NAKAMURA, S ;
ALMAGOR, Y ;
MAIELLO, L ;
MARTINI, G ;
GAGLIONE, A ;
GOLDBERG, SL ;
TOBIS, JM .
CIRCULATION, 1995, 91 (06) :1676-1688
[9]   ANGIOGRAPHIC PREDICTORS OF RECURRENCE OF RESTENOSIS AFTER WIKTOR STENT IMPLANTATION IN NATIVE CORONARY-ARTERIES [J].
DEJAEGERE, P ;
SERRUYS, PW ;
BERTRAND, M ;
WIEGAND, V ;
MARQUIS, JF ;
VROLICX, M ;
PIESSENS, J ;
VALEIX, B ;
KOBER, G ;
BONNIER, H ;
RUTSCH, W ;
UEBIS, R .
AMERICAN JOURNAL OF CARDIOLOGY, 1993, 72 (02) :165-170
[10]  
Fernandez-Aviles F., 1997, Journal of the American College of Cardiology, V29, p369A