On-line HPLC-UV/nano-TiO2-ICPMS system for the determination of inorganic selenium species

被引:79
作者
Sun, YC [1 ]
Chang, YC [1 ]
Su, CK [1 ]
机构
[1] Natl Tsing Hua Univ, Nucl Sci & Technol Dev Ctr, Hsinchu 30043, Taiwan
关键词
D O I
10.1021/ac051899b
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
We have developed an UV/nano-TiO2 vapor generation (VG) device that when coupled between a chromatographic column and an ICP mass spectrometer provides a simple and sensitive hyphenated method for the determination of Se(IV) and Se(VI) without the need to use conventional chemical VG techniques. Because our proposed VG device allows both Se(IV) and Se(VI) species in the column effluent to be converted on-line into volatile Se products, which are then measured directly by the ICPMS, the safety risks and the probability of contamination arising from the use of additional chemicals are both low. To achieve the maximum signal intensity, we optimized a number of the operating parameters of the UV/nano-TiO2 VG device, including the acidity, the amounts of TiO2 and formic acid, and the length of the reaction coil, with respect to their effects on the reduction efficiency of the analyte species. This hyphenated method achieves excellent detection limits-0.06 and 0.03 ng mL(-1) for Se(IV) and Se(VI), respectively-because of the high efficiencies of the conversions of Se(IV) and Se(VI) to their respective volatile products and the lower blank level achieved, relative to those of other traditional systems. In addition, because the conversion efficiency of the analyte selenium species reached its maximum level within 36 s of irradiation, the working time (similar to 12 min) was limited primarily by time required for the chromatographic separation. A series of validation experiments-analysis of the 1643e Standard Reference Material and natural water samples-indicated that our proposed methods can be applied satisfactorily to the determination of inorganic selenium species in water samples.
引用
收藏
页码:2640 / 2645
页数:6
相关论文
共 39 条
[1]  
ADBULLAH M, 1994, J PHYS CHEM-US, V94, P6820
[2]  
AGAKI H, 1973, CHEMOSPHERE, V2, P131
[3]   Simultaneous spectrofluorimetric determination of selenium(IV) and (VI) by flow injection analysis [J].
Ahmed, MJ ;
Stalikas, CD ;
Veltsistas, PG ;
TzouwaraKarayanni, SM ;
Karayannis, MI .
ANALYST, 1997, 122 (03) :221-226
[5]   Flow injection electrochemical hydride generation of hydrogen selenide on lead cathode: Critical study of the influence of experimental parameters [J].
Bolea, E ;
Laborda, F ;
Castillo, JR .
ANALYTICAL SCIENCES, 2003, 19 (03) :367-372
[6]   Interferences in electrochemical hydride generation of hydrogen selenide [J].
Bolea, E ;
Laborda, F ;
Belarra, MA ;
Castillo, YR .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2001, 56 (12) :2347-2360
[7]   Development of a multi-element hydride generation inductively coupled plasma mass spectrometry procedure for the simultaneous determination of arsenic, antimony and selenium in waters [J].
Bowman, J ;
Fairman, B ;
Catterick, T .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1997, 12 (03) :313-316
[8]  
CRANE M, 1992, ARCH ENVIRON CON TOX, V23, P440
[9]   PHOTOCHEMICAL DECOMPOSITION OF ORGANIC-COMPOUNDS IN WATER AFTER UV-IRRADIATION - INVESTIGATION OF POSITIVE MUTAGENIC EFFECTS [J].
DEVEER, I ;
MORISKE, HJ ;
RUDEN, H .
TOXICOLOGY LETTERS, 1994, 72 (1-3) :113-119
[10]   Evaluation of electrochemical hydride generation for the determination of arsenic and selenium in sea water by graphite furnace atomic absorption with in situ concentration [J].
Ding, WW ;
Sturgeon, RE .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1996, 51 (11) :1325-1334