Experimental Investigation of Aerodynamic Characteristics for Three Typical Micro Wind Turbines at Low Reynolds Number

被引:3
作者
Zhu, J. Y. [1 ,2 ]
Zhang, L. [3 ]
Qu, Q. L. [2 ]
Liu, P. Q. [2 ]
机构
[1] Shenyang Aerosp Univ, Coll Aeroengine, Shenyang 110136, Liaoning, Peoples R China
[2] Beihang Univ, Key Lab Fluid Mech, Minist Educ, Beijing 100083, Peoples R China
[3] Shenyang Acad Environm Sci, Shenyang 110167, Liaoning, Peoples R China
关键词
Wind energy; Small wind turbine; Aerodynamic characteristics; Low Reynolds number; Wind; tunnel test; PERFORMANCE; DESIGN;
D O I
10.36884/jafm.13.04.30644
中图分类号
O414.1 [热力学];
学科分类号
摘要
Onsite utilization of wind energy in the urban environment is an effective solution to environmental protection and energy security. The typically micro wind turbines, including Savonius vertical axis wind turbine, H-type vertical axis wind turbine and micro horizontal axis wind turbine are more suitable for distributed generation, relative to centralized generation of large scale wind turbines. However, the wind in the urban environment characterized by low wind speed, high levels of turbulence and strongly unsteady direction and speed, directly affecting the aerodynamic characteristics of wind turbine. In the present work, wind tunnel tests have been conducted to investigate the low Reynolds number effect on aerodynamic characteristics for these three typical micro wind turbines, and the aerodynamic differences among them have been compared qualitatively and quantitatively. The experimental results show that micro horizontal axis wind turbine and H-type vertical axis wind turbine, belonging to lift-type wind turbine, have relatively higher startup wind speed and lower power coefficient due to deteriorative aerodynamic performance of airfoil at low wind speed. However, Savonius vertical axis wind turbine, as a drag-type wind turbine, exhibits excellent aerodynamic performance at low Reynolds number. The Savonius wind turbine has apparent output power at 5m/s, and the peak power coefficient exceeding 0.2 at 9m/s being superior to that of two other lift-type wind turbines at the same wind speed. In addition, in consideration of natural advantage of vertical axis wind turbine, Savonius wind turbine is the best option for applying at low Reynolds number urban environment.
引用
收藏
页码:1143 / 1148
页数:6
相关论文
共 15 条
[1]   A review on the performance of Savonius wind turbines [J].
Akwa, Joao Vicente ;
Vielmo, Horacio Antonio ;
Petry, Adriane Prisco .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (05) :3054-3064
[2]   Vertical axis wind turbine - A review of various configurations and design techniques [J].
Bhutta, Muhammad Mahmood Aslam ;
Hayat, Nasir ;
Farooq, Ahmed Uzair ;
Ali, Zain ;
Jamil, Sh. Rehan ;
Hussain, Zahid .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2012, 16 (04) :1926-1939
[3]  
Dayan E., 2006, Refocus, V7, P33, DOI [10.1016/S1471-0846(06)70545-5, DOI 10.1016/S1471-0846(06)70545-5]
[4]  
Driss Z, 2013, AM J MECH ENG, V1, P143
[5]  
Gipe P., 1999, WIND ENERGY BASICS
[6]   Review of fluid dynamics aspects of Savonius-rotor-based vertical-axis wind rotors [J].
Kang, Can ;
Liu, Haixia ;
Yang, Xin .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2014, 33 :499-508
[7]   Review of aerodynamic developments on small horizontal axis wind turbine blade [J].
Karthikeyan, N. ;
Murugavel, K. Kalidasa ;
Kumar, S. Arun ;
Rajakumar, S. .
RENEWABLE & SUSTAINABLE ENERGY REVIEWS, 2015, 42 :801-822
[8]   Roof mounting site analysis for micro-wind turbines [J].
Ledo, L. ;
Kosasih, P. B. ;
Cooper, P. .
RENEWABLE ENERGY, 2011, 36 (05) :1379-1391
[9]  
Mertens S., 2002, REFOCUS, V3, P22, DOI DOI 10.1016/S1471-0846(02)80023-3
[10]   Micro wind turbines in the UK domestic sector [J].
Peacock, A. D. ;
Jenkins, D. ;
Ahadzi, M. ;
Berry, A. ;
Turan, S. .
ENERGY AND BUILDINGS, 2008, 40 (07) :1324-1333