Determination of pesticides fenoxycarb and permethrin by sequential injection chromatography using miniaturized monolithic column

被引:30
作者
Chocholous, Petr [1 ]
Satinsky, Dalibor [1 ]
Sladkovsky, Radek [1 ]
Pospisilova, Marie [1 ]
Solich, Petr [1 ]
机构
[1] Charles Univ Prague, Fac Pharm Hradec Kralove, Dept Analyt Chem, Hradec Kralove 50005, Czech Republic
关键词
Sequential injection chromatography (SIC); Chromolith (TM) monolithic column; Fenoxycarb; Permethrin; Pesticides; Spectrophotometric determination;
D O I
10.1016/j.talanta.2008.06.015
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Sequential injection chromatography system equipped with miniaturized 10mm monolithic column was used for fast simultaneous determination of two pesticides-fenoxycarb (FC) and permethrin (PM). The system was composed of a commercial sequential injection analysis (SIA) system (FIAlab (R) 3000, 6-port selection valve and 5.0 mL Syringe pump), commercially available column Chromolith (TM) RP-18e (10mm x 4.6 mm i.d.) (Merck (R), Germany) and CCD UV-vis detector (USB 2000, Ocean-optics) with 1.0cm Z-flow cell, absorbance was monitored at 225 nm. The mobile phase used for analysis was acetonitrile/water (60:40, v/v), flow rates were 0.6mLmin(-1) for elution of fenoxycarb and 1.2 mLmin(-1) for elution of permethrin. For each analysis 4.8 mL of mobile phase was used. The chromatographic resolution between both compounds was >8 and analysis time was <6.5 min under the optimal conditions. Limits of detection were determined at 2.0 mu g mL(-1) for fenoxycarb and 1.0 mu g mL(-1) for permethrin. Samples were prepared by diluting with mobile phase and injected volume was 10 mu L for each analysis. Developed method was applied to analysis of both pesticides in veterinary pharmaceutical foams and sprays ARPALIT (R) Neo (Aveflor, Czech Republic). SIC method was compared with validated method (HPLC, reverse phase 100 mm monolithic column, gradient elution). (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:566 / 570
页数:5
相关论文
共 24 条
[1]   Simultaneous determination of malathion, permethrin, DEET (N,N-diethyl-m-toluamide), and their metabolites in rat plasma and urine using high performance liquid chromatography [J].
Abu-Qare, AW ;
Abou-Donia, MB .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (02) :291-299
[2]   A hybrid FIA/HPLC system incorporating monolithic column chromatography [J].
Adcock, Jacqui L. ;
Francis, Paul S. ;
Agg, Kent M. ;
Marshall, Graham D. ;
Barnett, Neil W. .
ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) :136-141
[3]   An overview of sequential injection chromatography [J].
Chocholous, Petr ;
Solich, Petr ;
Satinsky, Dalibor .
ANALYTICA CHIMICA ACTA, 2007, 600 (1-2) :129-135
[4]  
CLEVER JB, 2006, 12 INT S LUM SPECTR
[5]   Determination of nine pyrethroid insecticides by high-performance liquid chromatography with post-column photoderivatization and detection based on acetonitrile chemiluminescence [J].
Galera, MM ;
García, MDG ;
Valverde, RS .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1113 (1-2) :191-197
[6]   Validated HPLC method for quantifying permethrin in pharmaceutical formulations [J].
García, E ;
García, A ;
Barbas, C .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 24 (5-6) :999-1004
[7]   Simultaneous determination of antioxidants, preservatives and sweetener additives in food and cosmetics by flow injection analysis coupled to a monolithic column [J].
Garcia-Jimenez, J. F. ;
Valencia, M. C. ;
Capitan-Vallvey, L. F. .
ANALYTICA CHIMICA ACTA, 2007, 594 (02) :226-233
[8]   Development of a new high performance low pressure chromatographic system using a multisyringe burette coupled to a chromatographic monolithic column [J].
Gonzalez-San Miguel, Hilda M. ;
Alpizar-Lorenzo, Jesus M. ;
Cerda-Martin, Victor .
TALANTA, 2007, 72 (01) :296-300
[9]   FUNDAMENTALS OF SINUSOIDAL FLOW SEQUENTIAL INJECTION SPECTROPHOTOMETRY [J].
GUBELI, T ;
CHRISTIAN, GD ;
RUZICKA, J .
ANALYTICAL CHEMISTRY, 1991, 63 (21) :2407-2413
[10]   Ultra-performance liquid chromatography-tandem mass spectrometry:: A novel challenge in multiresidue pesticide analysis in food [J].
Kovalczuk, Tomas ;
Jech, Martin ;
Poustka, Jan ;
Hajslova, Jana .
ANALYTICA CHIMICA ACTA, 2006, 577 (01) :8-17