High Failure Rate with the GAP II Ring and Impacted Allograft Bone in Severe Acetabular Defects

被引:20
作者
Buttaro, Martin A. [1 ]
Munoz de la Rosa, Diego [1 ]
Comba, Fernando [1 ]
Piccaluga, Francisco [1 ]
机构
[1] Italian Hosp Buenos Aires, Inst Orthopaed Carlos E Ottolenghi, Hip Surg Unit, Buenos Aires, DF, Argentina
关键词
REVISION TOTAL HIP; REINFORCEMENT DEVICE; RECONSTRUCTION; ARTHROPLASTY; COMPONENT; CAGE;
D O I
10.1007/s11999-012-2402-8
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background Reconstruction rings and bone allografts have been proposed to manage severe acetabular bone loss. However, a high early failure rate of the Graft Augmentation Prosthesis (GAP) II reinforcement ring (Stryker Orthopaedics, Mahwah, NJ, USA) has been reported in one small series. Questions/Purposes We therefore determined (1) the survival of this device in combination with impacted morselized allograft bone in patients with severe defects and (2) the complication rate. Methods We retrospectively reviewed 24 patients (21 aseptic and three septic) with severe acetabular bone loss (10 hips with Type III defects and 14 with Type IV defects according to the American Academy of Orthopaedic Surgeons classification). We determined function and numbers of failures. The minimum followup was 24 months (mean, 34 months; range, 24-72 months). Results At latest followup, the reconstruction had failed in nine of the 24 patients: six with aseptic loosening, three with infection. The average postoperative Merle d'Aubigne-Postel score of the patients whose reconstructions had not failed was 16.6 points; at latest followup, these patients had radiographic evidence of incorporation and consolidation of bone allografts. Seven of the nine patients whose reconstructions had failed underwent reoperation. Fatigue fracture of the ring at the plate-cup union occurred in five patients at an average of 45 months postoperatively. All patients with failed reconstructions who underwent reoperation were treated with Trabecular Metal TM (Zimmer Inc, Warsaw, IN, USA) cups and were functioning well at latest followup. Conclusions We observed a high rate (37%) of early catastrophic failures of the GAP II reconstruction ring, particularly in patients with Type IV defects. Due to this high failure rate, we have abandoned its use.
引用
收藏
页码:3148 / 3155
页数:8
相关论文
共 24 条
[1]  
Alfaro JJB, 2010, HIP INT, V20, pS119, DOI 10.5301/HIP.2010.5297
[2]   Modular femoral head dissociation after dislocation and entrapment in reconstruction ring: a case report [J].
Buttaro, M. ;
Comba, F. ;
Piccaluga, F. .
HIP INTERNATIONAL, 2007, 17 (01) :49-51
[3]   Vancomycin-supplement impacted bone allografts in infected hip arthroplasty - Two-stage revision results [J].
Buttaro, MA ;
Pusso, R ;
Piccaluga, F .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2005, 87B (03) :314-319
[4]   Vancomycin-supplemented cancellous bone allografts in hip revision surgery [J].
Buttaro, Martin ;
Comba, Fernando ;
Piccaluga, Francisco .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2007, (461) :74-80
[5]   Acetabular revision with metal mesh, impaction bone grafting, and a cemented cup [J].
Buttaro, Martin A. ;
Comba, Fernando ;
Pusso, Rodolfo ;
Piccaluga, Francisco .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (10) :2482-2490
[6]   Acetabular reconstruction with impacted bone allografts and cemented acetabular components [J].
Comba, F. ;
Buttaro, M. ;
Pusso, R. ;
Piccaluga, F. .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2006, 88B (07) :865-869
[7]  
DANTONIO JA, 1989, CLIN ORTHOP RELAT R, P126
[8]   FUNCTIONAL RESULTS OF HIP ARTHROPLASTY WITH ACRYLIC PROSTHESIS [J].
DAUBIGNE, RM ;
POSTEL, M .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1954, 36-A (03) :451-475
[9]   Fatigue failure of the GAP ring [J].
Duffy, Gavan P. ;
O'Connor, Mary I. ;
Brodersen, Mark P. .
JOURNAL OF ARTHROPLASTY, 2007, 22 (05) :711-714
[10]  
Fawcett K, 1987, TISSUE BANKING, P97