Accuracy and Interobserver Concordance of Echocardiographic Assessment of Right Ventricular Size and Systolic Function: A Quality Control Exercise

被引:100
|
作者
Ling, Lee Fong [1 ]
Obuchowski, Nancy A.
Rodriguez, Leonardo [1 ]
Popovic, Zoran [1 ]
Kwon, Deborah [1 ]
Marwick, Thomas H. [1 ]
机构
[1] Cleveland Clin, Inst Heart & Vasc, Cleveland, OH 44195 USA
关键词
Quality control; Right ventricular; Cardiac magnetic resonance; Echocardiography; TIME 3-DIMENSIONAL ECHOCARDIOGRAPHY; EJECTION FRACTION; AMERICAN-SOCIETY; EUROPEAN-ASSOCIATION; MAGNETIC-RESONANCE; HEART-FAILURE; MRI; RECOMMENDATIONS; REPRODUCIBILITY; VARIABILITY;
D O I
10.1016/j.echo.2012.03.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Accurate assessment of right ventricular (RV) size (RVS) and RV systolic function (RVSF) is vital in the management of various conditions, but their assessment is challenging using echocardiography. The aim of this study was to determine the accuracy and interobserver concordance of qualitative and quantitative RV echocardiography. Methods: Fifteen readers evaluated RV function in 12 patients (360 readings) who underwent echocardiography and cardiac magnetic resonance for RV assessment. Readers qualitatively estimated RVS and RVSF as normal, mild, moderate, or severe and then reassessed quantitatively by adding RV dimensions, fractional area change, S', tricuspid annular plane systolic excursion, and RV index of myocardial performance. Cardiac magnetic resonance was used as the reference standard for grading RVS and RVSF. Results: Quantitative measurements increased accuracy and interreader agreement compared to qualitative assessment alone, especially in normal categories. Readers' accuracy for diagnosing normal and severe RVS increased from 38% to 78% (P = .001) and from 70% to 97% (P = .018), and readers' accuracy for diagnosing normal and mild RVSF increased from 52% to 84% (P < .001) and from 36% to 56% (P = .001). Interreader agreement for classification of the subjects as normal or abnormal improved from a kappa value of 0.40 to 0.77 (fair to good agreement) for RVS and from 0.43 to 0.66 (moderate to good agreement) for RVSF. Conclusions: Visual estimation of RVS and RVSF is inaccurate and has wide interobserver variability. Quantitation improves accuracy and reliability, especially in distinction of normal and abnormal. The reliability of mild and moderate grades remains inadequate, and further guidance is needed for the classification of abnormal categories. (J Am Soc Echocardiogr 2012;25:709-13.)
引用
收藏
页码:709 / 713
页数:5
相关论文
共 50 条
  • [1] Reliability and Interobserver Concordance of Echocardiographic Diagnosis of Right Ventricular Size and Systolic Function - A Quality Control Exercise
    Ling, Lee F.
    Cook, Thomas
    Kwon, Deborah
    Rodriguez, L. Leonardo
    Popovic, Zoran
    Klein, Allan L.
    Grimm, Richard
    Thomas, James D.
    Marwick, Thomas H.
    CIRCULATION, 2011, 124 (21)
  • [2] Echocardiographic assessment of right ventricular systolic function
    Wu, Victor Chien-Chia
    Takeuchi, Masaaki
    CARDIOVASCULAR DIAGNOSIS AND THERAPY, 2018, 8 (01) : 70 - +
  • [3] Echocardiographic assessment of left ventricular systolic function
    Klaeboe, Lars Gunnar
    Edvardsen, Thor
    JOURNAL OF ECHOCARDIOGRAPHY, 2019, 17 (01) : 10 - 16
  • [4] Right ventricular outflow tract systolic excursion: a novel echocardiographic parameter of right ventricular function
    Asmer, Ihab
    Adawi, Salim
    Ganaeem, Majdi
    Shehadeh, Jeryes
    Shiran, Avinoam
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2012, 13 (10) : 871 - 877
  • [5] Echocardiographic evaluation of right ventricular systolic function: The traditional and innovative approach
    Smolarek, Dorota
    Gruchala, Marcin
    Sobiczewski, Wojciech
    CARDIOLOGY JOURNAL, 2017, 24 (05) : 563 - 572
  • [6] Echocardiographic assessment of right ventricular systolic function in Boxers with arrhythmogenic right ventricular cardiomyopathy
    Cunningham, S. M.
    Aona, B. D.
    Antoon, K.
    Rush, J. E.
    Barton, B. A.
    JOURNAL OF VETERINARY CARDIOLOGY, 2018, 20 (05) : 343 - 353
  • [7] Validation Study on the Accuracy of Echocardiographic Measurements of Right Ventricular Systolic Function in Pulmonary Hypertension
    Sato, Takahiro
    Tsujino, Ichizo
    Ohira, Hiroshi
    Oyama-Manabe, Noriko
    Yamada, Asuka
    Ito, Yoichi M.
    Goto, Chisa
    Watanabe, Taku
    Sakaue, Shinji
    Nishimura, Masaharu
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (03) : 280 - 286
  • [8] Echocardiographic assessment of right ventricular systolic function in healthy Beagle dogs compared to high field cardiac magnetic resonance imaging
    Toaldo, M. Baron
    Glaus, T.
    Campagna, I
    Matos, J. Novo
    Dennler, M.
    VETERINARY JOURNAL, 2021, 271
  • [9] Echocardiographic linear fractional shortening for quantification of right ventricular systolic function-A cardiac magnetic resonance validation study
    Srinivasan, Aparna
    Kim, Jiwon
    Khalique, Omar
    Geevarghese, Alexi
    Rusli, Melissa
    Shah, Tara
    Di Franco, Antonino
    Alakbarli, Javid
    Goldburg, Samantha
    Rozenstrauch, Meenakshi
    Devereux, Richard B.
    Weinsaft, Jonathan W.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2017, 34 (03): : 348 - 358
  • [10] Echocardiographic assessment of right ventricular systolic function in conscious healthy dogs: Repeatability and reference intervals
    Visser, Lance C.
    Scansen, Brian A.
    Schober, Karsten E.
    Bonagura, John D.
    JOURNAL OF VETERINARY CARDIOLOGY, 2015, 17 (02) : 83 - 96