Evaluation of Effects of Radiofrequency Ablation of Ex vivo Liver Using the 1-Fr Wire Electrode

被引:6
|
作者
Rustagi, Tarun [1 ]
Gleeson, Ferga C. [1 ]
Abu Dayyeh, Barham K. [1 ]
Topazian, Mark D. [1 ]
Levy, Michael J. [1 ]
机构
[1] Mayo Clin, Div Gastroenterol, 200 First St SW, Rochester, MN 55905 USA
关键词
EUS; RFA: hepatic; endoscopic; Habib; ablation; tumor; cancer; BARRETTS-ESOPHAGUS; FEASIBILITY; MANAGEMENT; TUMORS;
D O I
10.1097/MCG.0000000000000808
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Study Aims: Percutaneous and intraoperative radiofrequency ablation (RFA) has become a valued tool in the management of primary and secondary hepatic lesions. A recent FDA-approved endoscopic ultrasound (EUS)-guided RFA probe now offers promise to help manage such lesions. However, there are no data to determine the ideal power setting and duration of ablation needed to effectively treat hepatic masses. The aim of the study was to evaluate the macroscopic zone of hepatic injury for EUS-RFA using a variety of settings within a fresh porcine hepatic specimen. Methods: RFA was performed using the Habib EUS-RFA needle (EMcision Ltd, London, UK) which is a 1-Fr wire (0.33mm, 0.013 inch) with a working length of 190 cm. A step by step approach to deliver radiofrequency energy at 5, 10, 15, 20, and 50W of power and 10, 30, 60, 90, 120, and 300 seconds, respectively, was followed. Macroscopic and microscopic findings of the ablation zone were evaluated at each setting. Results: The maximal zone (diameter, 8.2 +/- 0.14 mm; length, 20.85 +/- 0.21 mm) of coagulative necrosis was achieved using an ablation power of 10W for duration of 90 seconds. Notably, increased power settings resulted in an unexpected and diminished effect on tissue destruction. Conclusions: Our findings support the use of 10W power for 90 seconds for maximum ablation in the liver. Our data also provide initial guidance and alternate settings to be considered when performing EUS-RFA to adjust the ablation power and duration to match the lesion size, shape, and risk of injury to adjacent structures.
引用
收藏
页码:168 / 171
页数:4
相关论文
共 35 条
  • [31] Measurements of temperature during thermal ablation treatments on ex vivo liver tissue using fiber Bragg grating sensors
    Palumbo, Giovanna
    Iadicicco, Agostino
    Campopiano, Stefania
    Tosi, Daniele
    Schena, Emiliano
    Massaroni, Carlo
    Carlomagno, Nicola
    Tammaro, Vincenzo
    Verze, Paolo
    Ippolito, Juliet
    2017 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC), 2017, : 517 - 522
  • [32] REAL-TIME SPATIOTEMPORAL CONTROL OF HIGH-INTENSITY FOCUSED ULTRASOUND THERMAL ABLATION USING ECHO DECORRELATION IMAGING IN EX VIVO BOVINE LIVER
    Abbass, Mohamed A.
    Killin, Jakob K.
    Mahalingam, Neeraja
    Hooi, Fong Ming
    Barthe, Peter G.
    Mast, T. Douglas
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2018, 44 (01) : 199 - 213
  • [33] Comparison Between Unipolar and Bipolar Radiofrequency Lesions Using an Irrigated Multi-Electrode Circular Ablation Catheter in the Canine Thigh Muscle Preparation: Effects of Electrode Contract on Lesion Size
    Ikeda, Atsushi
    Nakagawa, Hiroshi
    Govari, Assaf
    Klemm, Ofer
    Sharma, Tushar
    Pitha, Jan V.
    Lazzara, Ralph
    Jackman, Warren M.
    CIRCULATION, 2013, 128 (22)
  • [34] An Extended Flow Cytometry Evaluation of ex Vivo Expanded NK Cells Using K562.Clone1, a Feeder Cell Line Manufactured in Brazil
    Watanabe, Caroline Mitika
    Suzuki, Caroline Ishihama
    dos Santos, Alessandro Marins
    Aloia, Thiago Pinheiro Arrais
    Lee, Grace
    Wald, David
    Okamoto, Oswaldo Keith
    de Azevedo, Julia T. Cottas
    de Godoy, Juliana Aparecida Preto
    Santos, Fabio P. S.
    Weinlich, Ricardo
    Kerbauy, Lucila N.
    Kutner, Jose Mauro
    Paiva, Raquel de Melo Alves
    Hamerschlak, Nelson
    TRANSPLANTATION AND CELLULAR THERAPY, 2024, 30 (11): : 1063e1 - 1063e19
  • [35] In vivo evaluation of the effects of simultaneous inhibition of GLUT-1 and HIF-1α by antisense oligodeoxynucleotides on the radiosensitivity of laryngeal carcinoma using micro 18F-FDG PET/CT
    Shen, Li-Fang
    Zhao, Xin
    Zhou, Shui-Hong
    Lu, Zhong-Jie
    Zhao, Kui
    Fan, Jun
    Zhou, Min-Li
    ONCOTARGET, 2017, 8 (21) : 34709 - 34726