Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients

被引:10
|
作者
Zeimpekis, Konstantinos G. [1 ,2 ]
Geiger, Julia [3 ,4 ]
Wiesinger, Florian [5 ]
Delso, Gaspar [5 ]
Kellenberger, Christian J. [3 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Raemistr 100, CH-8091 Zurich, Switzerland
[2] ETH, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[3] Univ Childrens Hosp Zurich, Dept Diagnost Imaging, Zurich, Switzerland
[4] Univ Childrens Hosp Zurich, Childrens Res Ctr, Zurich, Switzerland
[5] GE Healthcare, Waukesha, WI USA
关键词
Adolescents; Children; Cones; Cystic fibrosis; Lung density; Magnetic resonance imaging; Ultra-short echo time; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; COMPUTED-TOMOGRAPHY; MOTION CORRECTION; CT DENSITY; MRI; DISEASE; QUALITY; HEAD;
D O I
10.1007/s00247-020-04791-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background MRI of lung parenchyma is challenging because of the rapid decay of signal by susceptibility effects of aerated lung on routine fast spin-echo sequences. Objective To assess lung signal intensity in children on ultrashort echo-time sequences in comparison to a fast spin-echo technique. Materials and methods We conducted a retrospective study of lung MRI obtained in 30 patients (median age 5 years, range 2 months to 18 years) including 15 with normal lungs and 15 with cystic fibrosis. On a fast spin-echo sequence with radial readout and an ultrashort echo-time sequence, both lungs were segmented and signal intensities were extracted. We compared lung-to-background signal ratios and histogram analysis between the two patient cohorts using non-parametric tests and correlation analysis. Results On ultrashort echo-time the lung-to-background ratio was age-dependent, ranging from 3.15 to 1.33 with high negative correlation (R-s= -0.86). Signal in posterior dependent portions of the lung was 18% and 11% higher than that of the anterior lung for age groups 0-2 and 2-18 years, respectively. The fast spin-echo sequence showed no variation of signal ratios by age or location, with a median of 0.99 (0.98-1.02). Histograms of ultrashort echo-time slices between controls and children with aggravated cystic fibrosis with mucus plugging and wall thickening exhibited significant discrepancies that differentiated between normal and pathological lungs. Conclusion Signal intensity of lung on ultrashort echo-time is higher than that on fast spin-echo sequences, is age-dependent and shows a gravity-dependent anterior to posterior gradient. This signal variation appears similar to lung density described on CT.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 50 条
  • [41] Ultra-short echo-time magnetic resonance imaging distinguishes ischemia/reperfusion injury from acute rejection in a mouse lung transplantation model
    Chuck, Natalie C.
    Boss, Andreas
    Wurnig, Moritz C.
    Weiger, Markus
    Yamada, Yoshito
    Jungraithmayr, Wolfgang
    TRANSPLANT INTERNATIONAL, 2016, 29 (01) : 108 - 118
  • [42] Assessment of lung deformation in patients with idiopathic pulmonary fibrosis with elastic registration technique on pulmonary three-dimensional ultrashort echo time MRI
    Xiaoyan Yang
    Pengxin Yu
    Haishuang Sun
    Mei Deng
    Anqi Liu
    Chen Li
    Wenyan Meng
    Wenxiu Xu
    Bingbing Xie
    Jing Geng
    Yanhong Ren
    Rongguo Zhang
    Min Liu
    Huaping Dai
    Insights into Imaging, 15
  • [43] Evaluation of regional lung mass and growth in neonates with bronchopulmonary dysplasia using ultrashort echo time magnetic resonance imaging
    Giltmier, Andrew J.
    Higano, Nara S.
    Woods, Jason C.
    Kingma, Paul S.
    PEDIATRIC PULMONOLOGY, 2024, 59 (01) : 55 - 62
  • [44] Diagnostic Accuracy of Three-dimensional Turbo Field Echo Magnetic Resonance Imaging Sequence in Pediatric Tracheobronchial Anomalies with Congenital Heart Disease
    Hou, QiaoRu
    Gao, Wei
    Zhong, YuMin
    Sun, AiMin
    Wang, Qian
    Hu, LiWei
    Wang, JingLei
    SCIENTIFIC REPORTS, 2018, 8
  • [45] Three-Dimensional Phase Resolved Functional Lung Magnetic Resonance Imaging
    Klimes, Filip
    Voskrebenzev, Andreas
    Wacker, Frank
    Vogel-Claussen, Jens
    JOVE-JOURNAL OF VISUALIZED EXPERIMENTS, 2024, (208):
  • [46] Tissue Electrical Property Mapping From Zero Echo-Time Magnetic Resonance Imaging
    Lee, Seung-Kyun
    Bulumulla, Selaka
    Wiesinger, Florian
    Sacolick, Laura
    Sun, Wei
    Hancu, Ileana
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2015, 34 (02) : 541 - 550
  • [47] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Duffy, Patrick B.
    Stemmer, Alto
    Callahan, Michael J.
    Cravero, Joseph P.
    Johnston, Patrick R.
    Warfield, Simon K.
    Bixby, Sarah D.
    PEDIATRIC RADIOLOGY, 2021, 51 (09) : 1645 - 1653
  • [48] Free-breathing radial stack-of-stars three-dimensional Dixon gradient echo sequence in abdominal magnetic resonance imaging in sedated pediatric patients
    Patrick B. Duffy
    Alto Stemmer
    Michael J. Callahan
    Joseph P. Cravero
    Patrick R. Johnston
    Simon K. Warfield
    Sarah D. Bixby
    Pediatric Radiology, 2021, 51 : 1645 - 1653
  • [49] Ultra-short echo-time magnetic resonance imaging lung segmentation with under-Annotations and domain shift
    Guo, Fumin
    Capaldi, Dante Pi
    McCormack, David G.
    Fenster, Aaron
    Parraga, Grace
    MEDICAL IMAGE ANALYSIS, 2021, 72
  • [50] Pulmonary Embolism Detection with Three-dimensional Ultrashort Echo Time MR Imaging: Experimental Study in Canines
    Bannas, Peter
    Bell, Laura C.
    Johnson, Kevin M.
    Schiebler, Mark L.
    Francois, Christopher J.
    Motosugi, Utaroh
    Consigny, Daniel
    Reeder, Scott B.
    Nagle, Scott K.
    RADIOLOGY, 2016, 278 (02) : 413 - 421