Three-dimensional magnetic resonance imaging ultrashort echo-time cones for assessing lung density in pediatric patients

被引:10
|
作者
Zeimpekis, Konstantinos G. [1 ,2 ]
Geiger, Julia [3 ,4 ]
Wiesinger, Florian [5 ]
Delso, Gaspar [5 ]
Kellenberger, Christian J. [3 ,4 ]
机构
[1] Univ Hosp Zurich, Dept Nucl Med, Raemistr 100, CH-8091 Zurich, Switzerland
[2] ETH, Dept Informat Technol & Elect Engn, Zurich, Switzerland
[3] Univ Childrens Hosp Zurich, Dept Diagnost Imaging, Zurich, Switzerland
[4] Univ Childrens Hosp Zurich, Childrens Res Ctr, Zurich, Switzerland
[5] GE Healthcare, Waukesha, WI USA
关键词
Adolescents; Children; Cones; Cystic fibrosis; Lung density; Magnetic resonance imaging; Ultra-short echo time; OVERLAPPING PARALLEL LINES; ENHANCED RECONSTRUCTION PROPELLER; COMPUTED-TOMOGRAPHY; MOTION CORRECTION; CT DENSITY; MRI; DISEASE; QUALITY; HEAD;
D O I
10.1007/s00247-020-04791-1
中图分类号
R72 [儿科学];
学科分类号
100202 ;
摘要
Background MRI of lung parenchyma is challenging because of the rapid decay of signal by susceptibility effects of aerated lung on routine fast spin-echo sequences. Objective To assess lung signal intensity in children on ultrashort echo-time sequences in comparison to a fast spin-echo technique. Materials and methods We conducted a retrospective study of lung MRI obtained in 30 patients (median age 5 years, range 2 months to 18 years) including 15 with normal lungs and 15 with cystic fibrosis. On a fast spin-echo sequence with radial readout and an ultrashort echo-time sequence, both lungs were segmented and signal intensities were extracted. We compared lung-to-background signal ratios and histogram analysis between the two patient cohorts using non-parametric tests and correlation analysis. Results On ultrashort echo-time the lung-to-background ratio was age-dependent, ranging from 3.15 to 1.33 with high negative correlation (R-s= -0.86). Signal in posterior dependent portions of the lung was 18% and 11% higher than that of the anterior lung for age groups 0-2 and 2-18 years, respectively. The fast spin-echo sequence showed no variation of signal ratios by age or location, with a median of 0.99 (0.98-1.02). Histograms of ultrashort echo-time slices between controls and children with aggravated cystic fibrosis with mucus plugging and wall thickening exhibited significant discrepancies that differentiated between normal and pathological lungs. Conclusion Signal intensity of lung on ultrashort echo-time is higher than that on fast spin-echo sequences, is age-dependent and shows a gravity-dependent anterior to posterior gradient. This signal variation appears similar to lung density described on CT.
引用
收藏
页码:57 / 65
页数:9
相关论文
共 50 条
  • [21] Three-dimensional ultrashort echo magnetic resonance imaging of orthodontic appliances in the natural dentition
    Cox, Ryan J.
    Kau, Chung How
    Rasche, Volker
    AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2012, 142 (04) : 552 - 561
  • [22] Three-dimensional ultrashort echo time cones T1ρ (3D UTE-cones-T1ρ) imaging
    Ma, Ya-Jun
    Carl, Michael
    Shao, Hongda
    Tadros, Anthony S.
    Chang, Eric Y.
    Du, Jiang
    NMR IN BIOMEDICINE, 2017, 30 (06)
  • [23] Fast quantitative three-dimensional ultrashort echo time (UTE) Cones magnetic resonance imaging of major tissues in the knee joint using extended sprial sampling
    Wan, Lidi
    Ma, Yajun
    Yang, Jiawei
    Jerban, Saeed
    Searleman, Adam C.
    Carl, Michael
    Le, Nicole
    Chang, Eric Y.
    Tang, Guangyu
    Du, Jiang
    NMR IN BIOMEDICINE, 2020, 33 (10)
  • [24] Three-dimensional ultrashort echo time magnetic resonance imaging in assessment of idiopathic pulmonary fibrosis, in comparison with high-resolution computed tomography
    Yang, Xiaoyan
    Liu, Min
    Duan, Jianghui
    Sun, Haishuang
    An, Jing
    Benkert, Thomas
    Dai, Huaping
    Wang, Chen
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2022, 12 (08) : 4176 - +
  • [25] Optimized three-dimensional ultrashort echo time: Magnetic resonance fingerprinting for myelin tissue fraction mapping
    Zhou, Zihan
    Li, Qing
    Liao, Congyu
    Cao, Xiaozhi
    Liang, Hui
    Chen, Quan
    Pu, Run
    Ye, Huihui
    Tong, Qiqi
    He, Hongjian
    Zhong, Jianhui
    HUMAN BRAIN MAPPING, 2023, 44 (06) : 2209 - 2223
  • [26] In Vitro Imaging of Kidney Stones Using Ultra-short Echo-time Magnetic Resonance
    Ibrahim, El-Sayed
    Pooley, Robert
    Cernigliaro, Joseph
    Bridges, Mellena
    Giesbrandt, Jamie
    Williams, James
    Haley, William
    2015 IEEE 12th International Symposium on Biomedical Imaging (ISBI), 2015, : 1466 - 1469
  • [27] Zero echo time pediatric musculoskeletal magnetic resonance imaging: initial experience
    Sandberg, Jesse K.
    Young, Victoria A.
    Yuan, Jianmin
    Hargreaves, Brian A.
    Wishah, Fidaa
    Vasanawala, Shreyas S.
    PEDIATRIC RADIOLOGY, 2021, 51 (13) : 2549 - 2560
  • [28] Ability of three-dimensional 3-Tesla ultrashort echo time magnetic resonance imaging to display the morphological characteristics of pulmonary nodules: a sensitivity analysis
    Wang, Funan
    Lin, Xi
    Lin, Chong
    Huang, Guoqiang
    Li, Min
    Zhu, Liuhong
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2023, 13 (03) : 1792 - 1801
  • [29] Three-dimensional adiabatic inversion recovery prepared ultrashort echo time cones (3D IR-UTE-Cones) imaging of cortical bone in the hip
    Nazaran, Amin
    Carl, Michael
    Ma, Yajun
    Jerban, Saeed
    Zhu, Yanchun
    Lu, Xing
    Du, Jiang
    Chang, Eric Y.
    MAGNETIC RESONANCE IMAGING, 2017, 44 : 60 - 64
  • [30] Review of the ultrashort echo time magnetic resonance imaging of cortical bone
    Bao Shang-Lian
    Du Jiang
    Gao Song
    ACTA PHYSICA SINICA, 2013, 62 (08)