Automatic Evaluation of Collimation Field Rotation Angle in Digital Radiographic Images

被引:0
|
作者
Starcevic, Dorde S. [1 ]
Ostojic, Vladimir S. [1 ]
Petrovic, Vladimir S. [1 ]
机构
[1] Univ Novi Sad Serbia, Fac Tech Sci, Dept Power Elect & Telecommun, Novi Sad, Serbia
关键词
collimation; digital radiography; histogram of oriented gradients; image processing; RECOGNITION;
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
In this paper we propose a method for automatic collimation border rotation angle detection. Algorithm utilizes pooling of image gradients based on their orientations to form a histogram of oriented gradients (HOG) with the goal of determining the dominant gradient orientation in the image as collimation border rotation angle. To avoid accumulation of lower magnitude gradients only a percentage of the highest magnitude gradients was used during HOG calculation. Algorithm was evaluated on image database consisting of 244 real clinical images. Performance was measured through mean absolute error (MAE) between manually determined collimation field rotation angle and the angle estimated by the algorithm. Algorithm has achieved MAE of 0.388 degrees when using 21 % of the highest magnitude gradients.
引用
收藏
页码:376 / 379
页数:4
相关论文
共 50 条
  • [31] Evaluation of resolution characteristics of digital intraoral radiographic images using a task transfer function
    Taku Kuramoto
    Shinya Takarabe
    Hiroki Tsuru
    Yusuke Shibayama
    Toyoyuki Kato
    Kazunori Yoshiura
    Oral Radiology, 2022, 38 : 638 - 644
  • [32] Digital radiographic images will benefit endodontic services
    Lavelle, CLB
    Wu, CJ
    ENDODONTICS & DENTAL TRAUMATOLOGY, 1995, 11 (06): : 253 - 260
  • [33] Evaluation of resolution characteristics of digital intraoral radiographic images using a task transfer function
    Kuramoto, Taku
    Takarabe, Shinya
    Tsuru, Hiroki
    Shibayama, Yusuke
    Kato, Toyoyuki
    Yoshiura, Kazunori
    ORAL RADIOLOGY, 2022, 38 (04) : 638 - 644
  • [34] DENTAL AUTOMATIC RADIOGRAPHIC PROCESSORS EVALUATION
    STOCKMAN, TD
    BLACKMAN, RB
    FOSTER, CD
    YOUNG, JM
    JOURNAL OF DENTAL RESEARCH, 1984, 63 : 195 - 195
  • [35] AUTOMATIC VERIFICATION OF RADIATION-FIELD SHAPE USING DIGITAL PORTAL IMAGES
    BIJHOLD, J
    GILHUIJS, KGA
    VANHERK, M
    MEDICAL PHYSICS, 1992, 19 (04) : 1007 - 1014
  • [36] Two-dimensional rotation angle dynamic measurement system combining laser collimation
    Lou Z.-B.
    Zhao H.
    Liu Q.
    Zheng C.
    Tao W.
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2019, 27 (03): : 561 - 568
  • [37] Automatic weld defect identification from radiographic images
    Zahran, O.
    Kasban, H.
    El-Kordy, M.
    Abd El-Samie, F. E.
    NDT & E INTERNATIONAL, 2013, 57 : 26 - 35
  • [38] Automatic background recognition and removal of computed radiographic images
    Zhang, J
    Huang, HK
    RADIOLOGY, 1996, 201 : 816 - 816
  • [39] Automatic segmentation of lung fields on chest radiographic images
    Carreira, MJ
    Cabello, D
    Mosquera, A
    COMPUTERS AND BIOMEDICAL RESEARCH, 1999, 32 (03): : 283 - 303
  • [40] An automatic system of classification of weld defects in radiographic images
    Vilar, Rafael
    Zapata, Juan
    Ruiz, Ramon
    NDT & E INTERNATIONAL, 2009, 42 (05) : 467 - 476