Automatic Evaluation of Collimation Field Rotation Angle in Digital Radiographic Images

被引:0
|
作者
Starcevic, Dorde S. [1 ]
Ostojic, Vladimir S. [1 ]
Petrovic, Vladimir S. [1 ]
机构
[1] Univ Novi Sad Serbia, Fac Tech Sci, Dept Power Elect & Telecommun, Novi Sad, Serbia
关键词
collimation; digital radiography; histogram of oriented gradients; image processing; RECOGNITION;
D O I
暂无
中图分类号
TN [电子技术、通信技术];
学科分类号
0809 ;
摘要
In this paper we propose a method for automatic collimation border rotation angle detection. Algorithm utilizes pooling of image gradients based on their orientations to form a histogram of oriented gradients (HOG) with the goal of determining the dominant gradient orientation in the image as collimation border rotation angle. To avoid accumulation of lower magnitude gradients only a percentage of the highest magnitude gradients was used during HOG calculation. Algorithm was evaluated on image database consisting of 244 real clinical images. Performance was measured through mean absolute error (MAE) between manually determined collimation field rotation angle and the angle estimated by the algorithm. Algorithm has achieved MAE of 0.388 degrees when using 21 % of the highest magnitude gradients.
引用
收藏
页码:376 / 379
页数:4
相关论文
共 50 条
  • [1] Automatic Evaluation of Digital Radiographic Images
    Das, S.
    Mukherjee, D.
    Shah, B. K.
    WELDING JOURNAL, 2011, 90 (11) : 29 - 31
  • [2] Automatic Cobb Angle Determination From Radiographic Images
    Sardjono, Tri Arief
    Wilkinson, Michael H. F.
    Veldhuizen, Albert G.
    van Ooijen, Peter M. A.
    Purnama, Ketut E.
    Verkerke, Gijsbertus J.
    SPINE, 2013, 38 (20) : E1256 - E1262
  • [3] Automatic detection of radiation fields in digital radiographic images
    Luo, JB
    Senn, RA
    INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 1999, 13 (01) : 149 - 168
  • [4] Scalable edge enhancement with automatic optimization for digital radiographic images
    Yin, LJ
    Basu, A
    Chang, JK
    PATTERN RECOGNITION, 2004, 37 (07) : 1407 - 1422
  • [5] AUTOMATIC CONTRAST CONTROL FOR DIGITAL SUBTRACTION OF RADIOGRAPHIC IMAGES.
    Chow, C.K.
    Niebuhr, K.E.
    1600, (15):
  • [6] THE EFFECT OF COLLIMATION ON STORAGE PHOSPHOR PLATE RADIOGRAPHIC IMAGES
    FREEDMAN, MT
    PE, EV
    LO, SB
    NELSON, MC
    MUN, SK
    RADIOLOGY, 1992, 185 : 159 - 159
  • [7] Denoising of Digital Radiographic Images with Automatic Regularization Based on Total Variation
    Lucchese, Mirko
    Borghese, N. Alberto
    IMAGE ANALYSIS AND PROCESSING - ICIAP 2009, PROCEEDINGS, 2009, 5716 : 711 - 720
  • [8] Digital measurement of radiographic tibial plateau angle. A comparison to measurement on printed digital images
    Lister, S. A.
    Roush, J. K.
    Renberg, W. C.
    VETERINARY AND COMPARATIVE ORTHOPAEDICS AND TRAUMATOLOGY, 2008, 21 (02) : 129 - 132
  • [9] Electronic collimation of radiographic images: does it comprise an overexposure risk?
    Tsalafoutas, Ioannis A.
    BRITISH JOURNAL OF RADIOLOGY, 2018, 91 (1086):
  • [10] Evaluation of a digital camera for acquiring radiographic images for telemedicine applications
    Krupinski, E
    Gonzales, M
    Gonzales, C
    Weinstein, RS
    TELEMEDICINE JOURNAL AND E-HEALTH, 2000, 6 (03): : 297 - 302