Diagnostic methods for time-resolved optical spectroscopy of shocked liquid deuterium

被引:11
作者
Dunham, G [1 ]
Bailey, JE
Carlson, A
Lake, P
Knudson, MD
机构
[1] Ktech Corp Inc, Albuquerque, NM 87106 USA
[2] Sandia Natl Labs, Albuquerque, NM 87185 USA
关键词
D O I
10.1063/1.1651632
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Sandia National Laboratories Z facility generates shocks in liquid deuterium with pressures up to 100 GPa. Temperature measurements using spectroscopy of the shocked D-2 self-emission can help discriminate between different deuterium equation of state models. Time-resolved spectra are recorded using four diagnostic systems, each composed of a fiber optic probe that transmits light from the shocked D-2 to a remote streaked spectrometer. Calibration of the entire system in the streaked mode is performed using a xenon arc lamp. The absolute xenon arc lamp spectrum is determined by comparison with National Institute of Standards and Technology (NIST) standards. Data analysis is performed by measuring the wavelength-dependent efficiency for each system and applying this to determine the shocked D-2 self-emission spectrum. Temperature is deduced from either the wavelength dependence of the spectral radiance, ignoring the absolute intensity, or from both the wavelength dependence and the absolute intensity. The shocked D-2 temperature uncertainties obtained with the methods described here are well below the differences between D-2 equation of state (EOS) models and these measurements should therefore provide new insight into D-2 EOS physics. (C) 2004 American Institute of Physics.
引用
收藏
页码:928 / 935
页数:8
相关论文
共 21 条
[1]   High-accuracy time- and space-resolved Stark shift measurements (invited) [J].
Bailey, JE ;
Adams, R ;
Carlson, AL ;
Ching, CH ;
Filuk, AB ;
Lake, P .
REVIEW OF SCIENTIFIC INSTRUMENTS, 1997, 68 (01) :1009-1014
[2]   Optical spectroscopy measurements of shock waves driven by intense z-pinch radiation [J].
Bailey, JE ;
Asay, J ;
Bernard, M ;
Carlson, AL ;
Chandler, GA ;
Hall, CA ;
Hanson, D ;
Johnston, R ;
Lake, P ;
Lawrence, J .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2000, 65 (1-3) :31-42
[3]   LASER INTERFEROMETER FOR MEASURING HIGH VELOCITIES OF ANY REFLECTING SURFACE [J].
BARKER, LM ;
HOLLENBACH, RE .
JOURNAL OF APPLIED PHYSICS, 1972, 43 (11) :4669-+
[4]   Optical probing of laser-induced indirectly driven shock waves in aluminum [J].
Basko, M ;
Lower, T ;
Kondrashov, VN ;
Kendl, A ;
Sigel, R ;
MeyerterVehn, J .
PHYSICAL REVIEW E, 1997, 56 (01) :1019-1031
[5]   Shock-induced transformation of liquid deuterium into a metallic fluid [J].
Celliers, PM ;
Collins, GW ;
Da Silva, LB ;
Gold, DM ;
Cauble, R ;
Wallace, RJ ;
Foord, ME ;
Hammel, BA .
PHYSICAL REVIEW LETTERS, 2000, 84 (24) :5564-5567
[6]   Accurate measurement of laser-driven shock trajectories with velocity interferometry [J].
Celliers, PM ;
Collins, GW ;
Da Silva, LB ;
Gold, DM ;
Cauble, R .
APPLIED PHYSICS LETTERS, 1998, 73 (10) :1320-1322
[7]   Wavelength-dependent measurements of optical-fiber transit time, material dispersion, and attenuation [J].
Cochrane, K ;
Bailey, JE ;
Lake, P ;
Carlson, A .
APPLIED OPTICS, 2001, 40 (01) :150-156
[8]   Temperature measurements of shock compressed liquid deuterium up to 230 GPa [J].
Collins, GW ;
Celliers, PM ;
Da Silva, LB ;
Cauble, R ;
Gold, DM ;
Foord, ME ;
Holmes, NC ;
Hammel, BA ;
Wallace, RJ ;
Ng, A .
PHYSICAL REVIEW LETTERS, 2001, 87 (16) :art. no.-165504
[9]   Dynamical and optical properties of warm dense hydrogen [J].
Collins, LA ;
Bickham, SR ;
Kress, JD ;
Mazevet, S ;
Lenosky, TJ ;
Troullier, NJ ;
Windl, W .
PHYSICAL REVIEW B, 2001, 63 (18)
[10]   Absolute equation of state measurements on shocked liquid deuterium up to 200 GPa (2 Mbar) [J].
DaSilva, LB ;
Celliers, P ;
Collins, GW ;
Budil, KS ;
Holmes, NC ;
Barbee, TW ;
Hammel, BA ;
Kilkenny, JD ;
Wallace, RJ ;
Ross, M ;
Cauble, R ;
Ng, A ;
Chiu, G .
PHYSICAL REVIEW LETTERS, 1997, 78 (03) :483-486