Non-Gaussian chemical process monitoring with adaptively weighted independent component analysis and its applications

被引:46
作者
Jiang, Qingchao [1 ]
Yan, Xuefeng [1 ]
机构
[1] E China Univ Sci & Technol, Key Lab Adv Control & Optimizat Chem Proc, Minist Educ, Shanghai 200237, Peoples R China
基金
中国国家自然科学基金;
关键词
Chemical processes; Weighted independent component analysis; Process monitoring; Fault detection; MULTIDIMENSIONAL MUTUAL INFORMATION; PARTIAL LEAST-SQUARES; FAULT-DETECTION; DISCRIMINANT-ANALYSIS; DIMENSION REDUCTION; DIAGNOSIS; ICA; PCA;
D O I
10.1016/j.jprocont.2013.09.008
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Chemical process monitoring based on independent component analysis (ICA) is among the most widely used multivariate statistical process monitoring methods and has progressed very quickly in recent years. Generally, ICA methods initially employ several independent components (ICs) that are ordered according to certain criteria for process monitoring. However, fault information has no definite mapping relationship to a certain IC, and useful information might be submerged under the retained ICs. Thus, weighted independent component analysis (WICA) for fault detection and identification is proposed to process useful submerged information and reduce missed detection rates of I-2 statistics. The main idea of WICA is to initially build the conventional ICA model and then use the change rate of the I-2 statistic (RI2) to evaluate the importance of each IC. The important ICs tend to have higher RI2; thus, higher weighting values are then adaptively set for these ICs to highlight the useful fault information. Case studies on both simple simulated and Tennessee Eastman processes demonstrate the effectiveness of the WICA method. Monitoring results indicate that the performance of I-2 statistics improved significantly compared with principal component analysis and conventional ICA methods. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1320 / 1331
页数:12
相关论文
共 50 条
[21]   MULTIVARIATE STATISTICAL MONITORING OF PROCESS OPERATING PERFORMANCE [J].
KRESTA, JV ;
MACGREGOR, JF ;
MARLIN, TE .
CANADIAN JOURNAL OF CHEMICAL ENGINEERING, 1991, 69 (01) :35-47
[22]  
Kreyszig E., 1991, INTRO FUNCTIONAL ANA
[23]   Diagnosis of process faults in chemical systems using a local partial least squares approach [J].
Kruger, Uwe ;
Dimitriadis, Grigorios .
AICHE JOURNAL, 2008, 54 (10) :2581-2596
[24]   Disturbance detection and isolation by dynamic principal component analysis [J].
Ku, WF ;
Storer, RH ;
Georgakis, C .
CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 30 (01) :179-196
[25]   Integrating independent component analysis and local outlier factor for plant-wide process monitoring [J].
Lee, Jaeshin ;
Kang, Bokyoung ;
Kang, Suk-Ho .
JOURNAL OF PROCESS CONTROL, 2011, 21 (07) :1011-1021
[26]   Statistical monitoring of dynamic processes based on dynamic independent component analysis [J].
Lee, JM ;
Yoo, C ;
Lee, IB .
CHEMICAL ENGINEERING SCIENCE, 2004, 59 (14) :2995-3006
[27]   Fault detection of batch processes using multiway kernel principal component analysis [J].
Lee, JM ;
Yoo, C ;
Lee, IB .
COMPUTERS & CHEMICAL ENGINEERING, 2004, 28 (09) :1837-1847
[28]   Statistical process monitoring with independent component analysis [J].
Lee, JM ;
Yoo, CK ;
Lee, IB .
JOURNAL OF PROCESS CONTROL, 2004, 14 (05) :467-485
[29]  
Lee JM, 2007, CAN J CHEM ENG, V85, P526
[30]   Fault detection and diagnosis based on modified independent component analysis [J].
Lee, Jong-Min ;
Qin, S. Joe ;
Lee, In-Beum .
AICHE JOURNAL, 2006, 52 (10) :3501-3514