On-line solid-phase extraction gas chromatography ion trap tandem mass spectrometric detection for the nanogram per liter analysis of trace pollutants in aqueous samples

被引:37
作者
Verma, KK [1 ]
Louter, AJH [1 ]
Jain, A [1 ]
Pocurull, E [1 ]
Vreuls, JJ [1 ]
Brinkman, UAT [1 ]
机构
[1] FREE UNIV AMSTERDAM,DEPT ANALYT CHEM,NL-1081 HV AMSTERDAM,NETHERLANDS
关键词
solid-phase extraction; gas chromatography; ion trap tandem mass spectrometry; water samples; environmental analysis; pesticides; bromide; nitrite;
D O I
10.1007/BF02466313
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
On-line solid-phase extraction-gas chromatography-ion-trap tandem mass spectrometry (SPE-GC-MS/MS) has been used for the trace-level determination of polar and apolar pesticides. The SPE-GC interface, an Autoloop 2000, was operated at an injection temperature of 90 degrees C which permitted the determination of thermolabile pesticides such as carbofuran and carbaryl. Rectilinear calibration curves were obtained for the analytes tested over a range of 0.1-500 ng L-1, using a sample volume of 10-100 mt for enrichment on an SPE cartridge packed with styrene-divinylbenzene copolymer. The detection limits for the pesticides were in the 0.01-4 ng L-1 range. For a number of pesticides acceptable tandem mass spectra were obtained at levels as low as 0.1 ng L-1 level in real-life water samples. As a demonstration of the applicability of this technique for inorganic anions, bromide and nitrite were converted into 4-bromoacetanilide and 2-phenylphenol, respectively. The reaction products were pooled and subjected to simultaneous analysis by the present method using full-scan mass spectrometric detection. The detection limits were 0.3 and 2 ng L-1, respectively.
引用
收藏
页码:372 / 380
页数:9
相关论文
共 33 条
[1]   AUTOMATIC GAS-CHROMATOGRAPHIC DETERMINATION OF N-METHYLCARBAMATES IN MILK WITH ELECTRON-CAPTURE DETECTION [J].
BALLESTEROS, E ;
GALLEGO, M ;
VALCARCEL, M .
ANALYTICAL CHEMISTRY, 1993, 65 (13) :1773-1778
[2]   APPLICATIONS OF GAS-CHROMATOGRAPHY MASS-SPECTROMETRY IN MONITORING ENVIRONMENTALLY IMPORTANT COMPOUNDS [J].
BARCELO, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1991, 10 (10) :323-329
[3]   On-line sample handling strategies for the trace-level determination of pesticides and their degradation products in environmental waters [J].
Barcelo, D ;
Hennion, MC .
ANALYTICA CHIMICA ACTA, 1995, 318 (01) :1-41
[5]   A REVIEW OF SOLID-PHASE EXTRACTION - BASIC PRINCIPLES AND NEW DEVELOPMENTS [J].
BERRUETA, LA ;
GALLO, B ;
VICENTE, F .
CHROMATOGRAPHIA, 1995, 40 (7-8) :474-483
[6]   UNCOATED CAPILLARY COLUMN INLETS (RETENTION GAPS) IN GAS-CHROMATOGRAPHY [J].
GROB, K ;
SCHILLING, B .
JOURNAL OF CHROMATOGRAPHY, 1987, 391 (01) :3-18
[7]   SOLVENT EFFECTS IN CAPILLARY GAS-CHROMATOGRAPHY [J].
GROB, K .
JOURNAL OF CHROMATOGRAPHY, 1983, 279 (NOV) :225-232
[8]  
GROB K, 1991, ON LINE COUPLED LC G
[9]   DIRECT DETERMINATION OF SOME CARBAMATE PESTICIDES IN WATER AND SOIL BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY [J].
GROU, E ;
RADULESCU, V ;
CSUMA, A .
JOURNAL OF CHROMATOGRAPHY, 1983, 260 (02) :502-506
[10]   SURFACE-WATER ANALYSIS (TRACE-ORGANIC CONTAMINANTS) AND EC REGULATIONS [J].
HENNION, MC ;
PICHON, V ;
BARCELO, D .
TRAC-TRENDS IN ANALYTICAL CHEMISTRY, 1994, 13 (09) :361-372