Novel membrane-tube type glaucoma shunt device for glaucoma surgery

被引:6
作者
Ahn, Byung Heon [1 ]
Hwang, Young Hoon [1 ]
Han, Jong Chul [2 ]
机构
[1] Konyang Univ, Dept Ophthalmol, Kims Eye Hosp, Myung Gok Eye Res Inst, 156 Youngdeungpo Dong 4ga, Seoul 150034, South Korea
[2] Sungkyunkwan Univ, Sch Med, Samsung Med Ctr, Dept Ophthalmol, Seoul, South Korea
关键词
glaucoma; glaucoma drainage device; intraocular pressure; surgery; trabeculectomy; FOLLOW-UP; TRABECULECTOMY; MODULATION; IMPLANT;
D O I
10.1111/ceo.12772
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Background: The background of this study is to introduce the surgical technique and outcomes of a novel membrane-tube (MT) type glaucoma shunt device (MicroMT), which was developed to achieve safer and more predictable intraocular pressure (IOP) control compared with conventional trabeculectomy. Design: This is a retrospective, non-comparative, interventional case series study. Participants: The MicroMT was implanted in 43 glaucomatous eyes with insufficient IOP control despite medical treatment. Methods: The MicroMT consists of an expanded polytetrafluoroethylene membrane and a silicone tube with an intraluminal stent, which allows aqueous drainage from the anterior chamber to the lamellar scleral flap. The intraluminal stent prevents excessive aqueous drainage and allows additional IOP reduction through retraction or removal of the stent. Main Outcome Measures: The main outcome measures of this study are IOP changes and complications. Results: The mean (SD) IOP decreased from a preoperative value of 22.5 (6.9) mmHg to 11.1 (3.6) mmHg 3 years after the operation (50.7% reduction from baseline; P<0.01). Intraluminal stent removal 4 weeks after the operation induced an additional 40.2% IOP reduction (P<0.01). When success was defined as an IOP between 6 and 21 mmHg, and an IOP reduction of >= 20% from baseline, the success rate was 89.5% at 3 years after the operation. No postoperative ocular hypotony (IOP <6 mmHg) or tube-related complications occurred. Conclusions: MicroMT implantation is a novel therapy that may reduce IOP safely and effectively, with no apparent risk of postoperative ocular hypotony. Glaucoma surgery using this device may be a good alternative to conventional glaucoma surgery.
引用
收藏
页码:776 / 782
页数:7
相关论文
共 10 条
[1]   Efficacy and safety of mitomycin-C in primary trabeculectomy - Five-year follow-up [J].
Bindlish, R ;
Condon, GP ;
Schlosser, JD ;
D'Antonio, J ;
Lauer, KB ;
Lehrer, R .
OPHTHALMOLOGY, 2002, 109 (07) :1336-1341
[2]  
Choi You-Jin, 2003, Korean J Ophthalmol, V17, P106
[3]   Postoperative Complications in the Tube Versus Trabeculectomy (TVT) Study During Five Years of Follow-up [J].
Gedde, Steven J. ;
Herndon, Leon W. ;
Brandt, James D. ;
Budenz, Donald L. ;
Feuer, William J. ;
Schiffman, Joyce C. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2012, 153 (05) :804-814
[4]   Modulation of wound healing after glaucoma surgery [J].
Khaw, Peng T. ;
Chang, Lydia ;
Wong, Tina T. L. ;
Mead, Anna ;
Daniels, Julie T. ;
Cordeiro, M. Francesca .
CURRENT OPINION IN OPHTHALMOLOGY, 2001, 12 (02) :143-148
[5]   Clinical experience of e-PTFE membrane implant surgery for refractory glaucoma [J].
Kim, C ;
Kim, Y ;
Choi, S ;
Lee, S ;
Ahn, B .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2003, 87 (01) :63-70
[6]   Randomized, Prospective, Comparative Trial of EX-PRESS Glaucoma Filtration Device versus Trabeculectomy (XVT Study) [J].
Netland, Peter A. ;
Sarkisian, Steven R., Jr. ;
Moster, Marlene R. ;
Ahmed, Iqbal Ike K. ;
Condon, Garry ;
Salim, Sarwat ;
Sherwood, Mark B. ;
Siegfried, Carla J. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2014, 157 (02) :433-440
[7]  
Seah S K, 1995, J Glaucoma, V4, P73
[8]   Wound Modulation After Filtration Surgery [J].
Seibold, Leonard K. ;
Sherwood, Mark B. ;
Kahook, Malik Y. .
SURVEY OF OPHTHALMOLOGY, 2012, 57 (06) :530-550
[9]   Fluid Dynamics of a Novel Micro-Fistula Implant for the Surgical Treatment of Glaucoma [J].
Sheybani, Arsham ;
Reitsamer, Herbert ;
Ahmed, Iqbal Ike K. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (08) :4789-4795
[10]  
Wang W, 2013, PLOS ONE, V8, DOI [10.1371/journal.pone.0063591, 10.1371/journal.pone.0076538, 10.1155/2013/758750]