Arm cuff in the measurement of blood pressure

被引:10
作者
Mattoo, TK [1 ]
机构
[1] Wayne State Univ, Childrens Hosp Michigan, Sch Med, Detroit, MI 48201 USA
关键词
blood pressure measurement; bladder dimensions; arm cuff; cuff selection;
D O I
10.1016/S0895-7061(01)02301-9
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Selection of an arm cuff of the right size is necessary for accurate measurement of blood pressure (BP). Incorrect measurement can result either in unnecessary investigations, treatment, and follow-up for the mistaken diagnosis of hypertension, or no treatment for hypertension in individuals mistakenly thought to have normal BP. This is of particular importance in children, who have age-dependent variations in body size and BP. Studies have revealed that health care providers often do not follow published guidelines concerning cuff selection for children. Perceptions larger BP cuffs are required if upper arm length is used as a criterion for cuff selection. In contrast, smaller cuffs are required if 40% of the upper mid-arm circumference is used as a criterion for cuff selection. No single cuff, when used in accordance with current recommendations, yields accurate systolic as well as diastolic BP. The century-old issue of how to select a right size arm cuff for an accurate measurement of BP remains unresolved. Am J Hypertens 2002;15:67S-68S (C) 2002 American Journal of Hypertension, Ltd.
引用
收藏
页码:67S / 68S
页数:2
相关论文
共 50 条
[21]   Effect of anticipation and cuff inflation on blood pressure during self-measurement [J].
Gazzola, Katia ;
Honingh, Marloes ;
Truijen, Jasper ;
Zuliani, Giovanni ;
Van den Born, Bert-Jan H. .
JOURNAL OF HYPERTENSION, 2018, 36 (09) :1798-1802
[22]   Influence of the arm position on intra-arterial blood pressure measurement [J].
RT Netea ;
PJ Bijlstra ;
JWM Lenders ;
P Smits ;
T Thien .
Journal of Human Hypertension, 1998, 12 :157-160
[23]   Influence of the arm position on intra-arterial blood pressure measurement [J].
Netea, RT ;
Bijlstra, PJ ;
Lenders, JWM ;
Smits, P ;
Thien, T .
JOURNAL OF HUMAN HYPERTENSION, 1998, 12 (03) :157-160
[24]   Arm and finger measurements in the third trimester: Implications for blood pressure measurement [J].
Eley, Victoria A. ;
Roberts, Leonie ;
Rickards, Leah ;
Pelecanos, Anita ;
Blackie, Annika ;
Zhang, Chu ;
Christensen, Rebecca ;
Barrett, Helen L. .
PREGNANCY HYPERTENSION-AN INTERNATIONAL JOURNAL OF WOMENS CARDIOVASCULAR HEALTH, 2018, 14 :105-109
[25]   Measuring blood pressure in the forearm of obese patients:: concordance with arm measurement [J].
Vinyoles, E ;
Pujol, E ;
de la Figuera, M ;
Tajada, C ;
Montero, P ;
García, D .
MEDICINA CLINICA, 2005, 124 (06) :213-214
[26]   Cuff width influence on blood pressure measurement during the pregnant-puerperal cycle [J].
Oliveira, SMJV ;
Arcuri, EAM ;
Santos, JLF .
JOURNAL OF ADVANCED NURSING, 2002, 38 (02) :180-189
[27]   Investigating the inaccuracies of indirect method of blood pressure measurement associated to the cuff constructing fabrics [J].
Naqvi, Shenela ;
Husain, Muhammad Dawood ;
Lewis, Philip .
MEHRAN UNIVERSITY RESEARCH JOURNAL OF ENGINEERING AND TECHNOLOGY, 2022, 41 (02) :127-134
[28]   Respiratory modulation of oscillometric cuff pressure pulses and Korotkoff sounds during clinical blood pressure measurement in healthy adults [J].
Chen, Diliang ;
Chen, Fei ;
Murray, Alan ;
Zheng, Dingchang .
BIOMEDICAL ENGINEERING ONLINE, 2016, 15
[29]   Respiratory modulation of oscillometric cuff pressure pulses and Korotkoff sounds during clinical blood pressure measurement in healthy adults [J].
Diliang Chen ;
Fei Chen ;
Alan Murray ;
Dingchang Zheng .
BioMedical Engineering OnLine, 15
[30]   Blood Pressure Measurement Method and Inter-Arm Differences: A Meta-Analysis [J].
Verberk, Willem J. ;
Kessels, Alfons G. H. ;
Thien, Theo .
AMERICAN JOURNAL OF HYPERTENSION, 2011, 24 (11) :1201-1208