A fast inverse consistent deformable image registration method based on symmetric optical flow computation

被引:92
作者
Yang, Deshan [1 ]
Li, Hua [1 ]
Low, Daniel A. [1 ]
Deasy, Joseph O. [1 ]
El Naqa, Issam [1 ]
机构
[1] Washington Univ, Sch Med, Dept Radiat Oncol, 4921 Parkview Pl, St Louis, MO 63110 USA
关键词
D O I
10.1088/0031-9155/53/21/017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Deformable image registration is widely used in various radiation therapy applications including daily treatment planning adaptation to map planned tissue or dose to changing anatomy. In this work, a simple and efficient inverse consistency deformable registration method is proposed with aims of higher registration accuracy and faster convergence speed. Instead of registering image I to a second image J, the two images are symmetrically deformed toward one another in multiple passes, until both deformed images are matched and correct registration is therefore achieved. In each pass, a delta motion field is computed by minimizing a symmetric optical flow system cost function using modified optical flow algorithms. The images are then further deformed with the delta motion field in the positive and negative directions respectively, and then used for the next pass. The magnitude of the delta motion field is forced to be less than 0.4 voxel for every pass in order to guarantee smoothness and invertibility for the two overall motion fields that are accumulating the delta motion fields in both positive and negative directions, respectively. The final motion fields to register the original images I and J, in either direction, are calculated by inverting one overall motion field and combining the inversion result with the other overall motion field. The final motion fields are inversely consistent and this is ensured by the symmetric way that registration is carried out. The proposed method is demonstrated with phantom images, artificially deformed patient images and 4D-CT images. Our results suggest that the proposed method is able to improve the overall accuracy (reducing registration error by 30% or more, compared to the original and inversely inconsistent optical flow algorithms), reduce the inverse consistency error (by 95% or more) and increase the convergence rate (by 100% or more). The overall computation speed may slightly decrease, or increase in most cases because the new method converges faster. Compared to previously reported inverse consistency algorithms, the proposed method is simpler, easier to implement and more efficient.
引用
收藏
页码:6143 / 6165
页数:23
相关论文
共 40 条
[1]   Symmetrical dense optical flow estimation with occlusions detection [J].
Alvarez, Luis ;
Deriche, Rachid ;
Papadopoulo, Theo .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 2007, 75 (03) :371-385
[2]  
[Anonymous], 2005, INFORM PROCESSING ME
[3]  
Ashburner J, 2000, HUM BRAIN MAPP, V9, P212, DOI 10.1002/(SICI)1097-0193(200004)9:4<212::AID-HBM3>3.0.CO
[4]  
2-#
[5]  
Avants B, 2004, LECT NOTES COMPUT SC, V3117, P99
[6]   CORRELATION OF PROJECTION RADIOGRAPHS IN RADIATION-THERAPY USING OPEN CURVE SEGMENTS AND POINTS [J].
BALTER, JM ;
PELIZZARI, CA ;
CHEN, GTY .
MEDICAL PHYSICS, 1992, 19 (02) :329-334
[7]   PERFORMANCE OF OPTICAL-FLOW TECHNIQUES [J].
BARRON, JL ;
FLEET, DJ ;
BEAUCHEMIN, SS .
INTERNATIONAL JOURNAL OF COMPUTER VISION, 1994, 12 (01) :43-77
[8]   Symmetric data attachment terms for large deformation image registration [J].
Beg, Mirza Faisal ;
Khan, Ali .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2007, 26 (09) :1179-1189
[9]   A multi-institution deformable registration accuracy study [J].
Brock, K. K. .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03) :S44-S44
[10]   THE LAPLACIAN PYRAMID AS A COMPACT IMAGE CODE [J].
BURT, PJ ;
ADELSON, EH .
IEEE TRANSACTIONS ON COMMUNICATIONS, 1983, 31 (04) :532-540