Implants with an Oxidized Surface Placed Predominately in Soft Bone Quality and Subjected to Immediate Occlusal Loading: Results from a 7-Year Clinical Follow-Up

被引:21
作者
Glauser, Roland [1 ,2 ]
机构
[1] Georgia Hlth Sci Univ, Coll Dent Med, Dept Oral Rehabil, Augusta, GA USA
[2] Georgia Hlth Sci Univ, Coll Dent Med, Dept Periodont, Augusta, GA USA
关键词
dental implants; immediate loading; immediate restoration; long-term; marginal bone level; microbiota; oxidized surface; RETAINED MANDIBULAR OVERDENTURES; OSSEOINTEGRATED DENTAL IMPLANTS; PARTIALLY EDENTULOUS JAWS; FIXED PARTIAL DENTURES; SINGLE-TOOTH IMPLANTS; TITANIUM IMPLANTS; ANTERIOR MAXILLA; COLONIZATION; RESTORATION; MULTICENTER;
D O I
10.1111/j.1708-8208.2011.00352.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The purpose of this clinical follow-up was to document the 7-year outcome of immediately loaded implants exhibiting an oxidized surface. Material and Methods: Thirty-eight patients received a total of 51 implant-supported fixed prostheses. The restorations were supported by 102 implants, the majority of which were placed in posterior regions (88%) and primarily in soft bone quality (76%). Radiographic examinations were performed at prosthesis insertion, at 1- and 6-month follow-ups, and annually at the 1- through 5-year follow-up visits. Marginal peri-implant soft tissue evaluations were conducted at all these follow-ups. This report presents the results after at least 7 years of loading. Results: After 7 years of prosthetic loading, the cumulative implant survival rate was 97.1% and the mean marginal bone remodeling was -1.51mm (SD 1.00, n=73) with significantly more initial remodeling at sites having received marginal guided bone regeneration procedures. A low rate of biological and technical complications was detected after 7 years of function. The quantification of intrasulcular plaque sampling showed no significant difference between teeth and implants. Conclusion: The 7-year follow-up data indicate that the introduced immediate loading protocol is a successful treatment alternative also including regions exhibiting soft bone conditions.
引用
收藏
页码:322 / 331
页数:10
相关论文
共 44 条
[1]  
Albrektsson T, 1986, Int J Oral Maxillofac Implants, V1, P11
[2]  
ALBREKTSSON T, 1986, DENT CLIN N AM, V30, P151
[3]  
Albrektsson T, 2000, APPL OSSEOINTEGRATIO, V1, P21
[4]  
Altman DG, 1999, PRACTICAL STAT MED R, P365
[5]   Immediate loading of single-tooth ITI implants in the anterior maxilla:: a prospective 5-year pilot study [J].
Andersen, E ;
Haanæs, HR ;
Knutsen, BM .
CLINICAL ORAL IMPLANTS RESEARCH, 2002, 13 (03) :281-287
[6]  
Avivi-Arber L, 1996, Int J Oral Maxillofac Implants, V11, P311
[7]   Clinical and radiographic comparison of implants in regenerated or native bone: 5-year results [J].
Benic, Goran I. ;
Jung, Ronald E. ;
Siegenthaler, David W. ;
Haemmerle, Christoph H. F. .
CLINICAL ORAL IMPLANTS RESEARCH, 2009, 20 (05) :507-513
[8]   Immediate/early function of Branemark System® TiUnite™ implants in fresh extraction sockets in maxillae and posterior mandibles:: An 18-month prospective clinical study [J].
Bogaerde, LV ;
Rangert, B ;
Wendelhag, I .
CLINICAL IMPLANT DENTISTRY AND RELATED RESEARCH, 2005, 7 :S121-S130
[9]  
Branemark P I, 1999, Clin Implant Dent Relat Res, V1, P2, DOI 10.1111/j.1708-8208.1999.tb00086.x
[10]  
Brunski J B, 1999, Adv Dent Res, V13, P99