Determination of chromium in river waters by electrothermal atomic absorption spectrometry with preconcentration on a tantalum wire

被引:13
|
作者
Amin, MN [1 ]
Okada, H
Itoh, S
Suzuki, T
Kaneco, S
Ohta, K
机构
[1] Mie Univ, Fac Engn, Dept Chem Mat, Tsu, Mie 5148507, Japan
[2] Mie Univ, Environm Preservat Ctr, Tsu, Mie 5148507, Japan
来源
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY | 2001年 / 371卷 / 08期
关键词
D O I
10.1007/s002160101089
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The preconcentration of chromium on tantalum wire followed by electrothermal atomic absorption spectrometry with a tungsten tube atomizer is described. The preconcentration is accomplished by adsorbing chromium on a tantalum wire. The optimal immersion time was 3 min. The best pH for chromium adsorption was 3. Under optimal conditions, the detection limit was 15 pg mL(-1) (3x S/N). The effects on the preconcentration of chromium by large amounts of contaminants were evaluated. Even though matrix elements existed in 10(3)-10(4)-fold excess in water, the chromium absorption signal was not affected by the matrix elements. The method with preconcentration on tantalum wire was applied to the determination of chromium in river water.
引用
收藏
页码:1130 / 1133
页数:4
相关论文
共 50 条
  • [1] Determination of chromium in river waters by electrothermal atomic absorption spectrometry with preconcentration on a tantalum wire
    Nurul Md. Amin
    Hidetoshi Okada
    Syn-ichi Itoh
    Tohru Suzuki
    Satoshi Kaneco
    Kiyohisa Ohta
    Fresenius' Journal of Analytical Chemistry, 2001, 371 : 1130 - 1133
  • [2] Determination of antimony in waters by electrothermal atomic absorption spectrometry with preconcentration on a tantalum wire
    Amin, N
    Kaneco, S
    Nomura, K
    Suzuki, T
    Ohta, K
    MICROCHIMICA ACTA, 2003, 141 (1-2) : 87 - 91
  • [3] Determination of Antimony in Waters by Electrothermal Atomic Absorption Spectrometry with Preconcentration on a Tantalum Wire
    Md. Nurul Amin
    Satoshi Kaneco
    Ken Nomura
    Tohru Suzuki
    Kiyohisa Ohta
    Microchimica Acta, 2003, 141 : 87 - 91
  • [4] Determination of gold in waters by electrothermal atomic absorption spectrometry with preconcentration on a tungsten bar
    Ohta, K.
    Yokoyama, M.
    Ogawa, J.
    Mizuno, T.
    Analusis, 24 (01):
  • [5] Determination of gold in waters by electrothermal atomic absorption spectrometry with preconcentration on a tungsten bar
    Ohta, K
    Yokoyama, M
    Ogawa, J
    Mizuno, T
    ANALUSIS, 1996, 24 (01) : 22 - 24
  • [6] DETERMINATION OF CHROMIUM(III) AND CHROMIUM(VI) IN RIVER WATER BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY AFTER SORPTION PRECONCENTRATION IN A MICROWAVE FIELD
    KUBRAKOVA, I
    KUDINOVA, T
    FORMANOVSKY, A
    KUZMIN, N
    TSYSIN, G
    ZOLOTOV, Y
    ANALYST, 1994, 119 (11) : 2477 - 2480
  • [7] DIRECT DETERMINATION OF CHROMIUM IN ESTUARINE AND COASTAL WATERS BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    APTE, SC
    COMBER, SDW
    GARDNER, MJ
    GUNN, AM
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1991, 6 (02) : 169 - 172
  • [8] DETERMINATION OF CHROMIUM(VI) IN RIVER WATER SAMPLES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY
    FUNG, YS
    SHAM, WC
    ANALYST, 1994, 119 (05) : 1029 - 1032
  • [9] Preconcentration technique for manganese by adsorption onto a tantalum wire for tungsten tube atomizer electrothermal atomization atomic absorption spectrometry
    Md. Nurul Amin
    Satoshi Kaneco
    Yukitake Nakano
    Hideyuki Katsumata
    Tohru Suzuki
    Kiyohisa Ohta
    Microchimica Acta, 2008, 162 : 73 - 79
  • [10] Preconcentration of trace lead by adsorption onto a tantalum wire for electrothermal atomization atomic absorption spectrometry with a tungsten tube atomizer
    Amin, Md. Nurul
    Kaneco, Satoshi
    Nakano, Yukitake
    Katsumata, Hideyuki
    Suzuki, Tohru
    Ohta, Kiyohisa
    MICROCHEMICAL JOURNAL, 2007, 86 (01) : 89 - 93