Superparamagnetic iron oxide - Enhanced MR imaging of head and neck lymph nodes

被引:112
|
作者
Mack, MG [1 ]
Balzer, JO [1 ]
Straub, R [1 ]
Eichler, K [1 ]
Vogl, TJ [1 ]
机构
[1] Univ Frankfurt, Dept Diagnost & Intervent Radiol, D-60590 Frankfurt, Germany
关键词
head and neck neoplasms; iron; lymphatic system; neoplasms; magnetic resonance (MR); contrast media;
D O I
10.1148/radiol.2221010225
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PURPOSE: To compare findings on superparamagnetic iron oxide (SPIO)-enhanced magnetic resonance (MR) images of the head and neck with those from resected lymph node specimens and to determine the effect of such imaging on surgical planning in patients with histopathologically proved squamous cell carci- noma of the head and neck. MATERIALS AND METHODS: Thirty patients underwent MR imaging with non- enhanced and SPIO-enhanced (2.6 mg Fe/kg intravenously) T1-weighted (500/15 [repetition time msec/echo time msec]) and T2-weighted (1,900/80) spin-echo and T2-weighted gradient-echo (GRE) (500/15, 15 degrees flip angle) sequences. Signal inten- sity decrease was measured, and visual analysis was performed. Surgical plans were modified, if necessary, according to MR findings. Histopathologic and MR findings were compared. RESULTS: Histopathologic evaluation of 1,029 lymph nodes revealed 69 were metastatic. MR imaging enabled detection of 59 metastases. Regarding lymph node levels, MR diagnosis was correct in 26 of 27 patients who underwent surgery: Only one metastasis was localized in level II with MR imaging, whereas histopathologic evaluation placed it at level Ill. Extent of surgery was changed in seven patients. SPIO-enhanced T2-weighted GRE was the best sequence for differentiating between benign and malignant lymph nodes. CONCLUSION: SPIO-enhanced MR imaging has an important effect on planning the extent of surgery. On a patient basis, SPIO-enhanced MR images compared well with resected specimens.
引用
收藏
页码:239 / 244
页数:6
相关论文
共 50 条
  • [41] LOCALIZATION OF P-31 MR SIGNAL WITH USE OF SUPERPARAMAGNETIC IRON-OXIDE PARTICLES
    ENGELSTAD, BL
    WHITE, DL
    MOSELEY, ME
    STARK, DD
    RADIOLOGY, 1990, 176 (02) : 467 - 472
  • [42] The nodal neck level of sentinel lymph nodes in mucosal head and neck cancer
    Shoaib, T
    Soutar, DS
    MacDonald, DG
    Gray, HW
    Ross, GL
    BRITISH JOURNAL OF PLASTIC SURGERY, 2005, 58 (06): : 790 - 794
  • [43] Detection of small hypervascular hepatocellular carcinomas in cirrhotic patients: Comparison of superparamagnetic iron oxide-enhanced MR imaging with dual-phase spiral CT
    Lee, JM
    Kim, IH
    Kwak, HS
    Youk, JH
    Han, YM
    Kim, CS
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (01) : 1 - 8
  • [44] Contrast enhancement with Gd-EOB-DTPA in MR imaging of hepatocellular carcinoma in mice: A comparison with superparamagnetic iron oxide
    Fujita, M
    Yamamoto, R
    FritzZieroth, B
    Yamanaka, T
    Takahashi, M
    Miyazawa, T
    Tatsuta, M
    Terada, N
    Hosomi, N
    Inoue, E
    Kuroda, C
    JMRI-JOURNAL OF MAGNETIC RESONANCE IMAGING, 1996, 6 (03): : 472 - 477
  • [45] USPIO-enhanced magnetic resonance imaging for nodal staging in patients with head and neck cancer
    Curvo-Semedo, Luis
    Diniz, Monica
    Migueis, Jorge
    Juliao, Maria-Jose
    Martins, Paula
    Pinto, Alda
    Caseiro-Alves, Filipe
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2006, 24 (01) : 123 - 131
  • [46] CLINICAL-APPLICATION OF SUPERPARAMAGNETIC IRON-OXIDE TO MR IMAGING OF TISSUE PERFUSION IN VASCULAR LIVER-TUMORS
    HAHN, PF
    STARK, DD
    WEISSLEDER, R
    ELIZONDO, G
    SAINI, S
    FERRUCCI, JT
    RADIOLOGY, 1990, 174 (02) : 361 - 366
  • [47] LIVER METASTASES - SAFETY AND EFFICACY OF DETECTION WITH SUPERPARAMAGNETIC IRON-OXIDE IN MR-IMAGING
    BELLIN, MF
    ZAIM, S
    AUBERTON, E
    SARFATI, G
    DURON, JJ
    KHAYAT, D
    GRELLET, J
    RADIOLOGY, 1994, 193 (03) : 657 - 663
  • [48] Characterization of focal liver lesions with superparamagnetic iron oxide-enhanced MR imaging: Value of distributional phase T1-weighted imaging
    Lee, JM
    Kim, CS
    Youk, JH
    Lee, MS
    KOREAN JOURNAL OF RADIOLOGY, 2003, 4 (01) : 9 - 18
  • [49] DASHED HOPES FOR MR IMAGING OF THE HEAD AND NECK - THE POWER OF THE NEEDLE
    YOUSEM, DM
    RADIOLOGY, 1992, 184 (01) : 25 - 26
  • [50] CT and MR imaging of head and neck tuberculosis
    Moon, WK
    Han, MH
    Chang, KH
    Im, JG
    Kim, HJ
    Sung, KJ
    Lee, HK
    RADIOGRAPHICS, 1997, 17 (02) : 391 - 402