Influence of dentin biomodification with epigallocatechin-3-gallate on the bond strength of self-etch adhesive: Twelve-month results

被引:20
|
作者
Neri, Jiovanne R. [1 ,2 ,3 ]
Yamauti, Monica [4 ]
da Silveira, Felipe D. [1 ]
Mendonca, Juliano S. [1 ]
de Carvalho, Ricardo M. [5 ]
Santiago, Sergio L. [1 ]
机构
[1] Univ Fed Ceara, Fac Pharm Dent & Nursing, Dept Restorat Dent, Fortaleza, Ceara, Brazil
[2] Univ Fortaleza, Grad Sch Dent, Fortaleza, Ceara, Brazil
[3] Univ Ctr Christus, Grad Sch Dent, Fortaleza, Ceara, Brazil
[4] Univ Fed Minas Gerais, Fac Dent, Dept Restorat Dent, Belo Horizonte, MG, Brazil
[5] Univ British Columbia, Fac Dent, Dept Oral Biol & Med Sci, Vancouver, BC, Canada
关键词
Self-etch adhesive; Dentine; MMP inhibitors; Micro-tensile; CARIES-AFFECTED DENTIN; COLLAGEN DEGRADATION; MATRIX METALLOPROTEINASES; INTRAPULPAL PRESSURE; ARTIFICIAL SALIVA; BIOFILM FORMATION; CHLORHEXIDINE; DURABILITY; RESIN; EGCG;
D O I
10.1016/j.ijadhadh.2016.08.007
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
To evaluate the effectiveness of dentin biomodification with epigallocatechin-3-gallate (EGCG) on the resin-dentin bonds over time. Twenty seven extracted human third molars were prepared to expose a flat dentin surface and divided into 3 groups (n=9). Dentin surfaces were dried and treated with 20 mu L aliquots of either distilled water (control); 2% chlorhexidine digluconate solution (CHX) or 0.1% EGCG aqueous solution. Solutions were rubbed for 60 s followed by bonding with Adper Easy One, and 5-mm-thick resin crown build-up. Bonded teeth were stored in distilled water for 24 h and then longitudinally sectioned to obtain bonded sticks. One-third of the specimens were immediately subjected to a micro tensile bond strength test in tension at 0.5 mm/min, while the remaining specimens were tested after six and twelve months of storage in distilled water at 37 degrees C. Data were analyzed with Two-way ANOVA and Holm-Sidak method. After 24 h of storage, mean bond strength values were not significantly different among all groups (p > 0.05). Bond strengths of EGCG and CHX remained stable after 6 and 12 months. (p > 0.05). To conclude, pretreatment with EGCG or CHX preserved the bonding of Adper Easy One to dentin after six and twelve months of storage. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:81 / 86
页数:6
相关论文
共 50 条
  • [11] Pretreatment with Sodium Fluoride Maintains Dentin Bond Strength of a Two-Step Self-Etch Adhesive after Thermal Stressing
    Neri, Jiovanne Rabelo
    Nojosa, Jacqueline de Santiago
    Yamauti, Monica
    Mendonca, Juliano Sartori
    Santiago, Sergio Lima
    JOURNAL OF ADHESIVE DENTISTRY, 2017, 19 (06): : 517 - 523
  • [12] Effect of epigallocatechin-3-gallate solutions on bond durability at the adhesive interface in caries-affected dentin
    Nogueira Fialho, Melissa Proenca
    Hass, Viviane
    Nogueira, Rodrigo Proenca
    Gomes Franca, Fabiana Mantovani
    Turssi, Cecilia Pedroso
    Basting, Roberta Tarkany
    Botelho Amaral, Flavia Lucisano
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2019, 91 : 398 - 405
  • [13] Aging Protocols and Their Effects on Bond Strength of Total-Etch and Self-Etch Adhesive Systems to Dentin
    Gomes, Isabella A.
    Gomes, Mario G. N.
    Amaral, Flavia L. B.
    Franca, Fabiana M. G.
    Basting, Roberta T.
    Bandeca, Matheus C.
    Diniz, Rafael S.
    Goncalves, Leticia M.
    Tavarez, Rudys R. de J.
    Turssi, Cecilia P.
    OPEN DENTISTRY JOURNAL, 2020, 14 : 408 - 415
  • [14] The effect of 6-month water storage on the bond strength of self-etch adhesives bonded to dentin
    Zander-Grande, Christiana
    Loguercio, Alessandro D.
    Stanislawczuk, Rodrigo
    Martins, Gislaine Cristine
    Mongruel Gomes, Osnara Maria
    Reis, Alessandra
    AMERICAN JOURNAL OF DENTISTRY, 2011, 24 (04): : 239 - 244
  • [15] Influence of different Er,Cr:YSGG laser parameters on long-term dentin bond strength of self-etch adhesive
    Yildirim, Tahsin
    Ayar, Muhammet Kerim
    Yesilyurt, Cemal
    LASERS IN MEDICAL SCIENCE, 2015, 30 (09) : 2363 - 2368
  • [16] Epigallocatechin-3-gallate/nanohydroxyapatite platform delivery approach to adhesive-dentin interface stability
    Yu, Jian
    Zhang, Zhongni
    Guo, Rui
    Peng, Wenan
    Yang, Hongye
    Huang, Cui
    MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2021, 122
  • [17] Shear bond strength of a self-etch adhesive to Er:YAG laser-prepared dentin
    Zhan, Zhenlin
    Wu, Weiliang
    Zhang, Xianzeng
    Zhao, Haibin
    Lin, Shi
    Xie, Shusen
    OPTICS IN HEALTH CARE AND BIOMEDICAL OPTICS IV, 2010, 7845
  • [18] Human dentin bond strength of chlorhexidine containing universal adhesive system used in total-etch and self-etch modes
    Tessore, Romina
    Silveira, Camila
    Vazquez, Priscila
    Mederos, Matias
    Garcia, Andres
    Cuevas-Suarez, Carlos Enrique
    Grazioli, Guillermo
    ODONTOESTOMATOLOGIA, 2020, 22 (35): : 20 - 29
  • [19] Effect of epigallocatechin-3-gallate and thermal cycling on the bond strength of resin cements to the root dentin
    Danielle Cristine Messias
    Moisés Franco Barbosa da Silva
    Natália Spadini de Faria
    Tatiane Rocco Dias-Arnez
    Fuad Jacob Rached-Júnior
    Ana Beatriz Silva Sousa
    Odontology, 2021, 109 : 854 - 859
  • [20] Microshear bond strength and interfacial morphology of etch-and-rinse and self-etch adhesive systems to superficial and deep dentin
    Yousry, Mai Mahmoud
    ElNaga, Albeer Abo
    Hafez, Randa M.
    El-Badrawy, Wafa
    QUINTESSENCE INTERNATIONAL, 2011, 42 (09): : E96 - E106