Graphical criterion for the detection of outliers in linear regression taking into account errors in both taxes

被引:14
作者
del Río, FJ [1 ]
Riu, J [1 ]
Rius, FX [1 ]
机构
[1] Univ Rovira & Virgili, Inst Adv Studies, Dept Analyt & Organ Chem, E-43005 Tarragona, Spain
关键词
outliers; linear regression; errors in both axes; Cook's test; confidence intervals;
D O I
10.1016/S0003-2670(01)00911-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Over the past few years linear regression taking into account the errors in both axes has become increasingly important in chemical analysis. It can be applied for instance in method comparison studies at several levels of concentration (where each of the two methods normally present errors of the same order of magnitude) or at calibration straight lines using reference materials as calibration standards, such as in X-ray, fluorescence for analysing geological samples. However, the results obtained by using a regression line may be biased due to one or more outlying points in the experimental data set. These situations can be overcome by robust regression methods or techniques for detecting outliers. This paper presents a graphical criterion for detecting outliers using the bivariate least squares (BLS) regression method, which takes into account the heteroscedastic individual errors in both axes. This graphical criterion is based on a modification of Cook's well-known test for detecting outliers. This new technique has been checked using two simulated data sets where an outlier is added, and one real data set corresponding to a method comparison analysis. (C) 2001 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:49 / 58
页数:10
相关论文
共 17 条
[1]  
BROWN ML, 1982, J AM STAT ASSOC, V377, P71
[2]   DETECTION OF INFLUENTIAL OBSERVATION IN LINEAR-REGRESSION [J].
COOK, RD .
TECHNOMETRICS, 1977, 19 (01) :15-18
[3]   INFRARED REFLECTION-ABSORPTION SPECTROSCOPY OF PHOTORESIST FILMS ON SILICON-WAFERS - MEASURING FILM THICKNESS AND REMOVING INTERFERENCE-FRINGES [J].
GAMSKY, CJ ;
HOWES, GR ;
TAYLOR, JW .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1015-1020
[4]   1988 COMPILATION REPORT ON TRACE-ELEMENTS IN 6 ANRT ROCK REFERENCE SAMPLES - DIORITE DR-N, SERPENTINE UB-N, BAUXITE BX-N, DISTHENE DT-N, GRANITE GS-N AND POTASH FELDSPAR FK-N [J].
GOVINDARAJU, K ;
ROELANDTS, I .
GEOSTANDARDS NEWSLETTER, 1989, 13 (01) :5-67
[5]   Robust orthogonal regression for the outlier detection when comparing two series of measurement results [J].
Hartmann, C ;
Vankeerberghen, P ;
SmeyersVerbeke, J ;
Massart, DL .
ANALYTICA CHIMICA ACTA, 1997, 344 (1-2) :17-28
[6]   MULTIPLE STRAIGHT-LINE LEAST-SQUARES ANALYSIS WITH UNCERTAINTIES IN ALL VARIABLES [J].
LISY, JM ;
CHOLVADOVA, A ;
KUTEJ, J .
COMPUTERS & CHEMISTRY, 1990, 14 (03) :189-192
[7]   MICROWAVE-ASSISTED EXTRACTION OF ORGANIC-COMPOUNDS FROM STANDARD REFERENCE SOILS AND SEDIMENTS [J].
LOPEZAVILA, V ;
YOUNG, R ;
BECKERT, WF .
ANALYTICAL CHEMISTRY, 1994, 66 (07) :1097-1106
[8]   STUDY OF ACCURACY IN CHEMICAL ANALYSIS USING LINEAR CALIBRATION CURVES [J].
MANDEL, J ;
LINNIG, FJ .
ANALYTICAL CHEMISTRY, 1957, 29 (05) :743-749
[9]  
MASSART DL, 1997, HDB CHEMOMETRICS QUA, P203
[10]   UNIVARIATE REGRESSION-MODELS WITH ERRORS IN BOTH AXES [J].
RIU, J ;
RIUS, FX .
JOURNAL OF CHEMOMETRICS, 1995, 9 (05) :343-362