Electron beam therapy with transverse magnetic fields

被引:22
|
作者
Nardi, E [1 ]
Barnea, G
机构
[1] Weizmann Inst Sci, Dept Particle Phys, IL-76100 Rehovot, Israel
[2] RAFAEL, IL-31021 Haifa, Israel
关键词
electron beam; magnetic field; Monte Carlo simulation;
D O I
10.1118/1.598490
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Detailed Monte Carlo electron transport simulations were carried out for the purpose of investigating the possibility of improving electron dose distribution for therapeutic applications, by using transverse magnetic fields. The case studied here is that of a 15 MeV electron beam of 6 cm diameter. The electrons pass through 4 cm of field-free tissue and a transverse magnet:ic field is applied for depth greater than 4 cm. A field of 3 T was found to improve the skin sparing factor by a factor of 2, when compared to field-free irradiation. A field of 2 T could also have a significant effect although less pronounced than 3 T while, for the case at hand, a magnetic field of only 1 T is not effective. The results here include detailed energy deposition contours in three dimensions. (C) 1999 American Association of Physicists in Medicine.
引用
收藏
页码:967 / 973
页数:7
相关论文
共 50 条
  • [11] NUMERICAL INVESTIGATION OF A PLASMA BEAM ENTERING TRANSVERSE MAGNETIC-FIELDS
    KOGA, J
    GEARY, JL
    FUJINAMI, T
    NEWBERGER, BS
    TAJIMA, T
    ROSTOKER, N
    JOURNAL OF PLASMA PHYSICS, 1989, 42 : 91 - 110
  • [12] Transport of an electron beam in the periodical nonsinusoidal magnetic fields
    Arkhipov, Andrey V.
    Darmaev, Alexander N.
    Komarov, Dmitriy A.
    Miroshnikov, Yuriy A.
    Morev, Sergey P.
    Fetisova, Alexandra V.
    2008 IEEE INTERNATIONAL VACUUM ELECTRONICS CONFERENCE, 2008, : 146 - 147
  • [13] Reconstruction of magnetic fields by reflection electron beam tomography
    Nomizu, S
    Yin, J
    Nakano, Y
    Ogawa, K
    Matsuda, J
    IEEE TRANSACTIONS ON MAGNETICS, 1996, 32 (05) : 4926 - 4928
  • [14] Reconstruction of magnetic fields by reflection electron beam tomography
    Nomizu, S.
    Yin, J.
    Nakano, Y.
    Ogawa, K.
    Matsuda, J.
    IEEE Transactions on Magnetics, 1996, 32 (5 pt 2): : 4926 - 4928
  • [15] Electron beam guiding by strong longitudinal magnetic fields
    Johzaki, T.
    Mima, K.
    Fujioka, S.
    Sakagami, H.
    Sunahara, A.
    Nagatomo, H.
    Shiraga, H.
    8TH INTERNATIONAL CONFERENCE ON INERTIAL FUSION SCIENCES AND APPLICATIONS (IFSA 2013), 2016, 688
  • [16] Simulation of the conditions of photon and electron beam irradiation in magnetic fields for increasing conformity of radiation therapy
    A. V. Belousov
    S. M. Varzar’
    A. P. Chernyaev
    Bulletin of the Russian Academy of Sciences: Physics, 2007, 71 (6) : 841 - 843
  • [17] Chaotic characteristics of electron motion in the static magnetic fields and self-fields of the electron beam
    Yin, YZ
    INTERNATIONAL JOURNAL OF INFRARED AND MILLIMETER WAVES, 1996, 17 (03): : 607 - 615
  • [18] FREE-ELECTRON LASERS WITH TRANSVERSE SYNCHRONIZING MAGNETIC-FIELDS
    BAZYLEV, VA
    TULUPOV, AV
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1991, 304 (1-3): : 427 - 431
  • [19] Monte Carlo characterization of clinical electron beams in transverse magnetic fields
    Lee, MC
    Ma, CM
    PHYSICS IN MEDICINE AND BIOLOGY, 2000, 45 (10): : 2947 - 2967
  • [20] ELECTRON FLOW THROUGH TRANSVERSE MAGNETIC-FIELDS IN MAGNETIC MULTIPOLE ARC DISCHARGES
    HOLMES, AJT
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1982, 53 (10): : 1517 - 1522