A new method for measuring the response time of the high pressure ionization chamber

被引:5
|
作者
Wang, Zhentao [1 ]
Shen, Yixiong [1 ]
An, Jigang [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 102201, Peoples R China
基金
中国国家自然科学基金;
关键词
Response time; High pressure ionization chamber; Drift time of ions;
D O I
10.1016/j.apradiso.2012.04.010
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Time response is an important performance characteristic for gas-pressurized ionization chambers. To study the time response, it is especially crucial to measure the ion drift time in high pressure ionization chambers. In this paper, a new approach is proposed to study the ion drift time in high pressure ionization chambers. It is carried out with a short-pulsed X-ray source and a high-speed digitizer. The ion drift time in the chamber is then determined from the digitized data. By measuring the ion drift time of a 15 atm xenon testing chamber, the method has been proven to be effective in the time response studies of ionization chambers. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1718 / 1722
页数:5
相关论文
共 50 条
  • [41] Performance of a high-pressure xenon ionization chamber for environmental radiation monitoring
    Kim, H. S.
    Park, S. H.
    Ha, J. H.
    Kim, Y. K.
    Kim, J. K.
    Cho, S. Y.
    RADIATION MEASUREMENTS, 2008, 43 (2-6) : 659 - 663
  • [42] Dual-anode high-pressure xenon cylindrical ionization chamber
    Bolotnikov, A
    Bolozdynya, A
    DeVito, R
    Richards, J
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (03) : 1262 - 1269
  • [43] MEASURING PRIMARY IONIZATION IN A DISCHARGE-CONDENSATION CHAMBER
    GRIGALASHVILI, NS
    DZHAVRISHVILI, AK
    VARSIMASHVILI, TV
    MANDZHAVIDZE, ZS
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1975, (05): : 46 - 48
  • [44] A new method of measuring blood pressure indirectly
    Peng, H.-X. (penghaixia4070926@126.com), 1600, Northeastern University (33):
  • [45] A NEW METHOD FOR MEASURING COLLOID OSMOTIC PRESSURE
    HANSEN, AT
    AMERICAN JOURNAL OF PHYSIOLOGY, 1950, 163 (03): : 720 - 720
  • [46] A new electromechanical method for measuring intraocular pressure
    Kontiola, A
    DOCUMENTA OPHTHALMOLOGICA, 1997, 93 (03) : 265 - 276
  • [47] A new electromechanical method for measuring intraocular pressure
    Antti Kontiola
    Documenta Ophthalmologica, 1997, 93 : 265 - 276
  • [48] Twin position sensitive ionization chamber, utilizing backgammon and time projection method
    O. V. Zeynalova
    Sh. S. Zeynalov
    F. -J. Hambsch
    S. Oberstedt
    Bulletin of the Russian Academy of Sciences: Physics, 2011, 75 (11) : 1527 - 1532
  • [49] The angular response of a plane parallel ionization chamber in high energy photon beam
    Geng, H.
    Yang, B.
    Cheung, K. Y.
    Yu, S. K.
    RADIOTHERAPY AND ONCOLOGY, 2014, 111 : S145 - S146
  • [50] HIGH-PRESSURE CHAMBER FOR MEASURING INTENSITY OF MAGNETIZATION USING PENDULUM BALANCES
    VERSENEV, YS
    GRAZHDAN.NP
    OLEINIK, MI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (05): : 1271 - &