A new method for measuring the response time of the high pressure ionization chamber

被引:5
|
作者
Wang, Zhentao [1 ]
Shen, Yixiong [1 ]
An, Jigang [1 ]
机构
[1] Tsinghua Univ, Inst Nucl & New Energy Technol, Beijing 102201, Peoples R China
基金
中国国家自然科学基金;
关键词
Response time; High pressure ionization chamber; Drift time of ions;
D O I
10.1016/j.apradiso.2012.04.010
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Time response is an important performance characteristic for gas-pressurized ionization chambers. To study the time response, it is especially crucial to measure the ion drift time in high pressure ionization chambers. In this paper, a new approach is proposed to study the ion drift time in high pressure ionization chambers. It is carried out with a short-pulsed X-ray source and a high-speed digitizer. The ion drift time in the chamber is then determined from the digitized data. By measuring the ion drift time of a 15 atm xenon testing chamber, the method has been proven to be effective in the time response studies of ionization chambers. (C) 2012 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1718 / 1722
页数:5
相关论文
共 50 条
  • [21] A NEW METHOD FOR TRACK ANGLE MEASUREMENT IN A GRIDDED IONIZATION CHAMBER
    FACCHINI, U
    GATTI, E
    PELLEGRINI, F
    NUCLEAR INSTRUMENTS & METHODS, 1959, 4 (04): : 221 - 227
  • [22] Method for measuring the response time: PQA
    Al Haddad, M
    Colley, M
    7TH WORLD MULTICONFERENCE ON SYSTEMICS, CYBERNETICS AND INFORMATICS, VOL XII, PROCEEDINGS: INFORMATION SYSTEMS, TECHNOLOGIES AND APPLICATIONS: II, 2003, : 273 - 278
  • [23] Use of the ionization chamber with high pressure for the study of gamma radiations and neutrons
    Savel, P
    JOURNAL DE PHYSIQUE ET LE RADIUM, 1933, 4 : 609 - 612
  • [24] Development of a High Pressure Xe Ionization Chamber for Environmental Radiation Spectroscopy
    Kim, Han Soo
    Kim, Yong Kyun
    Park, Se Hwan
    Ha, Jang Ho
    Kim, Jong Kyung
    Kang, Sang Mook
    Cho, Seung Yeon
    Kim, Do Hyun
    Chung, Eui Kwon
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 2008, : 383 - 386
  • [25] A NOTE ON A SELF-SEALING INSULATOR FOR A HIGH PRESSURE IONIZATION CHAMBER
    READ, J
    BRITISH JOURNAL OF RADIOLOGY, 1948, 21 (248): : 425 - 426
  • [26] A fast response time gas ionization chamber detector with a grid structure
    Chang, Jiahao
    Zhu, Chaoyang
    Song, Yuanpeng
    Wang, Zhentao
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2024, 32 (02) : 339 - 354
  • [27] APPARATUS FOR MEASURING IONIZATION IN A BUBBLE-CHAMBER
    ROB, L
    VRZAL, J
    CESKOSLOVENSKY CASOPIS PRO FYSIKU SEKCE A, 1974, 24 (04): : 370 - 372
  • [28] NEW METHOD FOR MEASURING BLADDER PRESSURE
    TAKAYAMA, K
    KITADA, S
    KUMAZAWA, J
    UROLOGY, 1987, 29 (06) : 632 - 634
  • [29] A new method for measuring osmotic pressure
    Townend, RV
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1928, 50 : 2958 - 2966
  • [30] Measuring the extraction time of negative ions from the ionization chamber of a static mass spectrometer
    V. G. Lukin
    G. S. Lomakin
    Instruments and Experimental Techniques, 2010, 53 : 401 - 403