Write field asymmetry in perpendicular magnetic recording

被引:3
|
作者
Li, Zhanjie [1 ]
Bai, Daniel Z. [1 ]
Lin, Ed [1 ]
Mao, Sining [1 ]
机构
[1] Western Digital Corp, Fremont, CA 94539 USA
关键词
RISE-TIME; HEAD;
D O I
10.1063/1.3679138
中图分类号
O59 [应用物理学];
学科分类号
摘要
We present a systematic study of write field asymmetry by using micromagnetic modeling for a perpendicular magnetic recording (PMR) writer structure. Parameters investigated include initial magnetization condition, write current amplitude, write current frequency, and initial write current polarity. It is found that the write current amplitude and frequency (data rate) are the dominant factors that impact the field asymmetry. Lower write current amplitude and higher write current frequency will deteriorate the write field asymmetry, causing recording performance (such as bit error rate) degradation. (C) 2012 American Institute of Physics. [doi:10.1063/1.3679138]
引用
收藏
页数:3
相关论文
共 50 条
  • [31] A Method to Localize RF B1 Field in High-Field Magnetic Resonance Imaging Systems
    Yoo, Hyoungsuk
    Gopinath, Anand
    Vaughan, J. Thomas
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2012, 59 (12) : 3365 - 3371
  • [32] Laser-Assisted Magnetic Recording Light-Delivery System with a Coupling Element and a Laterally Tapered Vertically Multistepped Waveguide
    Hasegawa, Shin-ya
    Odajima, Wataru
    OPTICAL REVIEW, 2011, 18 (01) : 47 - 53
  • [33] A Method to Control Non-uniformity RF B1 Field for High Field Magnetic Resonance Imaging
    Yoo, Hyoungsuk
    Gopinath, Anand
    Vaughan, J. Thomas
    2010 IEEE MTT-S INTERNATIONAL MICROWAVE SYMPOSIUM DIGEST (MTT), 2010, : 752 - 755
  • [34] An investigation of the performance of a coaxial HPGe detector operating in a magnetic resonance imaging field
    Harkness, L. J.
    Boston, A. J.
    Boston, H. C.
    Cole, P.
    Cresswell, J. R.
    Filmer, F.
    Jones, M.
    Judson, D. S.
    Nolan, P. J.
    Oxley, D. C.
    Sampson, J. A.
    Scraggs, D. P.
    Slee, M. J.
    Bimson, W. E.
    Kemp, G. J.
    Groves, J.
    Headspith, J.
    Lazarus, I.
    Simpson, J.
    Cooper, R. J.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 638 (01) : 67 - 73
  • [35] Magnetic Nanoparticle-Guided Blind Focusing of the Electric Field for Microwave Hyperthermia
    Bellizzi, Gennaro
    Bucci, Ovidio Mario
    IEEE ACCESS, 2017, 5 : 17246 - 17257
  • [36] PLACEMENT OF A FERROMAGNETIC INTRACEREBRAL ANEURYSM CLIP IN A MAGNETIC-FIELD WITH A FATAL OUTCOME
    KLUCZNIK, RP
    CARRIER, DA
    PYKA, R
    HAID, RW
    RADIOLOGY, 1993, 187 (03) : 855 - 856
  • [37] Flying stability of a slider with a damaged diamond like carbon layer induced by confined optical energy in a thermally assisted magnetic recording system
    Choi, Jonghak
    Park, Kyoung-Su
    Park, No-Cheol
    Park, Young-Pil
    MICROSYSTEM TECHNOLOGIES-MICRO-AND NANOSYSTEMS-INFORMATION STORAGE AND PROCESSING SYSTEMS, 2015, 21 (12): : 2509 - 2515
  • [38] Radio-frequency coils for ultra-high field magnetic resonance
    Ipek, Ozlem
    ANALYTICAL BIOCHEMISTRY, 2017, 529 : 10 - 16
  • [39] Improvement of Shock Resistance for Solid Immersion Lens-Based Near Field Recording System Using Air-Bearing Surface
    Lee, Yonghyun
    Lee, Yong-Eun
    Lee, Sang Jik
    Kim, Ki-Hoon
    Kim, Seokhwan
    Park, No-Cheol
    Park, Young-Pil
    Park, Kyoung-Su
    JAPANESE JOURNAL OF APPLIED PHYSICS, 2010, 49 (08)
  • [40] RF B1 Field Calculation With Transmission-Line Resonator Analysis for High-Field Magnetic Resonance Systems
    Yoo, Hyoungsuk
    Vaughan, J. Thomas
    Gopinath, Anand
    IEEE ANTENNAS AND WIRELESS PROPAGATION LETTERS, 2011, 10 : 592 - 595