Detection of haemorrhagic stroke in simulation and realistic 3-D human head phantom using microwave imaging

被引:37
作者
Sohani, Behnaz [1 ]
Khalesi, Banafsheh [1 ]
Ghavami, Navid [2 ]
Ghavami, Mohammad [1 ]
Dudley, Sandra [1 ]
Rahmani, Amir [3 ]
Tiberi, Gianluigi [1 ,2 ]
机构
[1] London South Bank Univ, Sch Engn, London, England
[2] UBT Umbria Bioengn Technol, Perugia, Italy
[3] Castlet Ltd, Lincoln, England
关键词
Microwave imaging; Brain stroke detection; Haemorrhagic stroke detection; Huygens principle; ACUTE ISCHEMIC-STROKE; TOMOGRAPHY;
D O I
10.1016/j.bspc.2020.102001
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This research presents the use and validation of a low complexity microwave imaging procedure for brain imaging, where antennas operate in free-space. In particular, we employ only two microstrip antennas, operating between 1 and 2 GHz for successful detection of the haemorrhagic stroke. Detection is demonstrated through simulation and measurements. Simulations have been performed using an anthropomorphic human head model where a haemorrhagic stroke has been inserted. In addition, multi-bistatic frequency-domain measurements have been performed to collect the transfer function (S21) between the two antennas inside an anechoic chamber using a multi-layered phantom mimicking a human head. Images have been obtained through Huygens principle. To reconstruct the image, subtraction artefact removal method between the data of a healthy head and the data of a head with stroke has been initially employed in simulations. Next, the rotation subtraction artefact removal method has been used both in simulation and in measurements. It has been verified that both artefact removal procedures allow detection. (C) 2020 Elsevier Ltd. All rights reserved.
引用
收藏
页数:10
相关论文
共 36 条
[1]  
Ahsan S., 2019, 13 EUR C ANT PROP
[2]   New Antenna Design for Hyperthermia Treatment of Human Head [J].
Aldhaeebi, Maged ;
Elshafiey, Ibrahim .
2014 UKSIM-AMSS 16TH INTERNATIONAL CONFERENCE ON COMPUTER MODELLING AND SIMULATION (UKSIM), 2014, :96-100
[3]   Microwave technology for detecting traumatic intracranial bleedings: tests on phantom of subdural hematoma and numerical simulations [J].
Candefjord, Stefan ;
Winges, Johan ;
Malik, Ahzaz Ahmad ;
Yu, Yinan ;
Rylander, Thomas ;
McKelvey, Tomas ;
Fhager, Andreas ;
Elam, Mikael ;
Persson, Mikael .
MEDICAL & BIOLOGICAL ENGINEERING & COMPUTING, 2017, 55 (08) :1177-1188
[4]   A prospective study of transmission of Multidrug-Resistant Organisms (MDROs) between environmental sites and hospitalized patientsthe TransFER study [J].
Chen, Luke F. ;
Knelson, Lauren P. ;
Gergen, Maria F. ;
Better, Olga M. ;
Nicholson, Bradly P. ;
Woods, Christopher W. ;
Rutala, William A. ;
Weber, David J. ;
Sexton, Daniel J. ;
Anderson, Deverick J. .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 2019, 40 (01) :47-52
[5]  
Coli V.L., 2018, IEEE, DOI [10.1109/APUSNCURSINRSM.2018.8609404, DOI 10.1109/APLISNCLIRSINRSM.2018.8609404]
[6]   ARTIFACT REMOVAL ALGORITHMS FOR MICROWAVE IMAGING OF THE BREAST [J].
Elahi, Muhammad A. ;
Glavin, Martin ;
Jones, Edward ;
O'Halloran, Martin .
PROGRESS IN ELECTROMAGNETICS RESEARCH-PIER, 2013, 141 :185-200
[7]   Confocal microwave Imaging for breast cancer detection: Localization of tumors in three dimensions [J].
Fear, EC ;
Li, X ;
Hagness, SC ;
Stuchly, MA .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2002, 49 (08) :812-822
[8]  
Ghavami N., 2016, I10 INT S COMM SYST, P1
[9]   Non-iterative beamforming based on Huygens principle for multistatic ultrawide band radar: application to breast imaging [J].
Ghavami, Navid ;
Smith, Penny Probert ;
Tiberi, Gianluigi ;
Edwards, David ;
Craddock, Ian .
IET MICROWAVES ANTENNAS & PROPAGATION, 2015, 9 (12) :1233-1240
[10]   UWB Microwave Imaging of Objects With Canonical Shape [J].
Ghavami, Navid ;
Tiberi, Gianluigi ;
Edwards, David J. ;
Monorchio, Agostino .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 2012, 60 (01) :231-239