A rapid HPLC-MS/MS method for determining busulfan in hemolytic samples from children with hematopoietic stem cell transplantation

被引:6
|
作者
Yuan Jinjie [1 ,2 ]
Sun, Ning [1 ]
Zhang, Shuyu [1 ]
Feng, Xinying [3 ]
Chen, Xijing [2 ]
Zhao, Di [2 ]
Zhao, Libo [1 ]
机构
[1] Capital Med Univ, Beijing Childrens Hosp, Clin Res Ctr, 56 Nanlishi Rd, Beijing 100045, Peoples R China
[2] China Pharmaceut Univ, Sch Basic Med & Clin Pharm, 639 Longmian Ave, Nanjing 211198, Peoples R China
[3] Zhengzhou Univ, Luoyang Cent Hosp, Phase Clin Trials Ctr 1, Luoyang, Peoples R China
关键词
busulfan; hemolytic samples; HPLC-MS; MS; HSCT; TDM; MASS-SPECTROMETRY METHOD; PERSONALIZED BUSULFAN; INTRAVENOUS BUSULFAN; HUMAN PLASMA; LC-MS/MS; PHARMACOKINETICS; QUANTITATION; QUANTIFICATION; EXPOSURE; DERIVATIZATION;
D O I
10.1002/bmc.4898
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A rapid and sensitive method for the quantitative detection of busulfan (BU) in children's hemolytic samples by HPLC-tandem mass spectrometry (MS/MS) was established. In this study, the sample preparation procedure involved a one-step protein precipitation with acetonitrile (ACN) solution, and the HPLC-MS/MS method used Hypersil GOLD C-18. The mobile phase consisted of 10 mMammonium acetate solution (containing 0.1% formic acid) and ACN with a flow rate of 0.4 mL/min. Multiple reaction monitoring modes were used for quantitative analysis and the ion pairs of BU and BU-d8 werem/z263.9 -> 150.9 and 272.0 -> 159.0, respectively. BU had a good linearity in the range of 0.01-10 mu g mL(-1). The intra- and inter-day relative error was between -7.21% and 8.26%, and the coefficient of variation was less than 12.64%. The average extraction recovery rate in plasma samples was 99.76% +/- 6.53%, and the matrix in normal plasma and hemolyzed plasma had no significant effect on the detection results. Normal and hemolytic samples could maintain good stability at 4, 25 and -40 degrees C. As a result, this method is particularly suitable for determining BU in hemolytic samples from children with hematopoietic stem cell transplantation (HSCT), and this study provides the methodological basis for further research on the pharmacokinetics of BU in children with HSCT.
引用
收藏
页数:10
相关论文
共 50 条
  • [21] HPLC-MS/MS method for the simultaneous determination of clopidogrel, its carboxylic acid metabolite and derivatized isomers of thiol metabolite in clinical samples
    Karazniewicz-Lada, Marta
    Danielak, Dorota
    Tezyk, Artur
    Zaba, Czeslaw
    Tuffal, Gilles
    Glowka, Franciszek
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2012, 911 : 105 - 112
  • [22] An HPLC-MS/MS method for the separation of α-retinyl esters from retinyl esters
    Goetz, Hilary J.
    Kopec, Rachel E.
    Riedl, Ken M.
    Cooperstone, Jessica L.
    Narayanasamy, Sureshbabu
    Curley, Robert W., Jr.
    Schwartz, Steven J.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1029 : 68 - 71
  • [23] A rapid HPLC-MS/MS method for the simultaneous determination of luteolin, resveratrol and their metabolites in rat plasma and its application to pharmacokinetic interaction studies
    Wu, Wenying
    Li, Kexin
    Zhao, Chen
    Ran, Xiaohua
    Zhang, Yu
    Zhang, Tianhong
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2022, 1191
  • [24] A rapid and sensitive HPLC-MS method for the detection of plasma and cellular rifampicin
    Hartkoorn, Ruben C.
    Khoo, Saye
    Back, David J.
    Tjia, John F.
    Waitt, Catriona J.
    Chaponda, Masautso
    Davies, Geraint
    Ardrey, Alison
    Ashleigh, Samantha
    Ward, Stephen A.
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 857 (01): : 76 - 82
  • [25] Rapid and sensitive method for simultaneous determination of first-line anti-tuberculosis drugs in human plasma by HPLC-MS/MS: Application to therapeutic drug monitoring
    Gao, Shouhong
    Wang, Zhipeng
    Xie, Xinfang
    You, Chunhua
    Yang, Yang
    Xi, Yanhai
    Chen, Wansheng
    TUBERCULOSIS, 2018, 109 : 28 - 34
  • [26] New dosing nomogram and population pharmacokinetic model for young and very young children receiving busulfan for hematopoietic stem cell transplantation conditioning
    Poinsignon, Vianney
    Faivre, Laura
    Nguyen, Laurent
    Neven, Benedicte
    Broutin, Sophie
    Moshous, Despina
    Bourget, Philippe
    Dufour, Christelle
    Dalle, Jean-Hugues
    Galambrun, Claire
    Devictor, Benedicte
    Kemmel, Veronique
    De Berranger, Eva
    Gandemer, Virginie
    Vannier, Jean Pierre
    Jubert, Charlotte
    Bondu, Sabrina
    Mir, Olivier
    Petain, Aurelie
    Vassal, Gilles
    Paci, Angelo
    PEDIATRIC BLOOD & CANCER, 2020, 67 (10)
  • [27] A sensitive and rapid HPLC-MS/MS method for the quantitative determination of trace amount of bromocriptine in small clinical prolactinoma tissue
    Zang, Qingce
    Liu, Yang
    He, Jiuming
    Yue, Xiaofei
    Zhang, Ruiping
    Wang, Renzhi
    Abliz, Zeper
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2015, 989 : 91 - 97
  • [28] A facile and sensitive HPLC-MS/MS method for quantification of 3,3′-diindolylmethane in plasma samples
    Lakeev, Alexander P.
    Yanovskaya, Elena A.
    Tsuran, Daria V.
    Bryushinina, Olga S.
    Abdrashitova, Natalia Yu.
    Zyuz'kova, Yulia G.
    Udut, Vladimir V.
    Kiselev, Vsevolod I.
    Kuznetsov, Igor N.
    BIOMEDICAL CHROMATOGRAPHY, 2022, 36 (03)
  • [29] A rapid method for the determination of levoglucosan in NIST standard reference material 1649a by HPLC-MS/MS
    Buiarelli, Francesca
    Di Filippo, Patrizia
    Pomata, Donatella
    Riccardi, Carmela
    Simonetti, Giulia
    ATMOSPHERIC ENVIRONMENT, 2018, 195 : 24 - 29
  • [30] A simple and rapid method for the identification and quantification of malachite green and its metabolite in hake by HPLC-MS/MS
    Nebot, Carolina
    Iglesias, Alejandra
    Barreiro, Rocio
    Manuel Miranda, Jose
    Vazquez, Beatriz
    Manuel Franco, Carlos
    Cepeda, Alberto
    FOOD CONTROL, 2013, 31 (01) : 102 - 107